Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection

Samo za registrovane korisnike
2023
Autori
Haššo, Marek
Sarakhman, Olha
Đurđić, Slađana
Stanković, Dalibor M.
Švorc, Lubomir
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
In this work, an advanced electrochemical platform was developed for the simple, rapid and sensitive determination of the polyphenolic compound tannic acid in various beverages using the combination of batch injection analysis with amperometric detection on a screen-printed carbon electrode. Several experimental parameters (pH of supporting electrolyte, detection potential, dispensing rate, injected volume, stirring) were consistently evaluated. The most favorable analytical performance in terms of sensitivity, selectivity, repeatability and sampling frequency was obtained in Britton-Robinson buffer pH 5.0 at a detection potential of +0.6 V vs. Ag/AgCl, a dispensing rate of 204 µL/s and an injected volume of 80 µL under stirring condition (1500 r.p.m.). The presented platform has advantages for routine analysis including portable and small-scale experimental setup, low sample consumption (∼100 µL), simple sample preparation (dilution in supporting electrolyte), high sampling frequency ...(180 injections per hour), low limit of detection (80 nM) and suitable precision (RSD = 4.2% for 10 μM tannic acid, n = 20). The applicability of the method was verified by analyzing several beverage samples (tea, wine) in spike-recovery assay with the recovery values for tannic acid ranging from 94 to 101 %. © 2023 Elsevier B.V.

Ključne reči:
Batch injection analysis with amperometric detection / Screen-printed carbon electrode / Tannic acid
Izvor:
Journal of Electroanalytical Chemistry, 2023, 942, 117578-
Finansiranje / projekti:
  • Ministarstvo nauke, tehnološkog razvoja i inovacija Republike Srbije, institucionalno finansiranje - 200168 (Univerzitet u Beogradu, Hemijski fakultet) (RS-MESTD-inst-2020-200168)
  • Grant Agency of the Slovak Republic VEGA [1/0159/20]
  • bilateral Slovak - Serbian cooperation within the Slovak Research and Development Agency (SK-SRB-21-0019)
  • bilateral project Serbia - Slovakia (project number 451-03-43/2022-09/03)
  • National Scholarship Programme of the Slovak Republic for the Support of Mobility of Students, PhD Students, University Teachers, Researchers and Artists

DOI: 10.1016/j.jelechem.2023.117578

ISSN: 1572-6657

WoS: 001015157000001

Scopus: 2-s2.0-85160810122
[ Google Scholar ]
7
6
URI
https://vinar.vin.bg.ac.rs/handle/123456789/11089
Kolekcije
  • 070 - Laboratorija za radioizotope
  • Radovi istraživača
Institucija/grupa
Vinča
TY  - JOUR
AU  - Haššo, Marek
AU  - Sarakhman, Olha
AU  - Đurđić, Slađana
AU  - Stanković, Dalibor M.
AU  - Švorc, Lubomir
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11089
AB  - In this work, an advanced electrochemical platform was developed for the simple, rapid and sensitive determination of the polyphenolic compound tannic acid in various beverages using the combination of batch injection analysis with amperometric detection on a screen-printed carbon electrode. Several experimental parameters (pH of supporting electrolyte, detection potential, dispensing rate, injected volume, stirring) were consistently evaluated. The most favorable analytical performance in terms of sensitivity, selectivity, repeatability and sampling frequency was obtained in Britton-Robinson buffer pH 5.0 at a detection potential of +0.6 V vs. Ag/AgCl, a dispensing rate of 204 µL/s and an injected volume of 80 µL under stirring condition (1500 r.p.m.). The presented platform has advantages for routine analysis including portable and small-scale experimental setup, low sample consumption (∼100 µL), simple sample preparation (dilution in supporting electrolyte), high sampling frequency (180 injections per hour), low limit of detection (80 nM) and suitable precision (RSD = 4.2% for 10 μM tannic acid, n = 20). The applicability of the method was verified by analyzing several beverage samples (tea, wine) in spike-recovery assay with the recovery values for tannic acid ranging from 94 to 101 %. © 2023 Elsevier B.V.
T2  - Journal of Electroanalytical Chemistry
T1  - Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection
VL  - 942
SP  - 117578
DO  - 10.1016/j.jelechem.2023.117578
ER  - 
@article{
author = "Haššo, Marek and Sarakhman, Olha and Đurđić, Slađana and Stanković, Dalibor M. and Švorc, Lubomir",
year = "2023",
abstract = "In this work, an advanced electrochemical platform was developed for the simple, rapid and sensitive determination of the polyphenolic compound tannic acid in various beverages using the combination of batch injection analysis with amperometric detection on a screen-printed carbon electrode. Several experimental parameters (pH of supporting electrolyte, detection potential, dispensing rate, injected volume, stirring) were consistently evaluated. The most favorable analytical performance in terms of sensitivity, selectivity, repeatability and sampling frequency was obtained in Britton-Robinson buffer pH 5.0 at a detection potential of +0.6 V vs. Ag/AgCl, a dispensing rate of 204 µL/s and an injected volume of 80 µL under stirring condition (1500 r.p.m.). The presented platform has advantages for routine analysis including portable and small-scale experimental setup, low sample consumption (∼100 µL), simple sample preparation (dilution in supporting electrolyte), high sampling frequency (180 injections per hour), low limit of detection (80 nM) and suitable precision (RSD = 4.2% for 10 μM tannic acid, n = 20). The applicability of the method was verified by analyzing several beverage samples (tea, wine) in spike-recovery assay with the recovery values for tannic acid ranging from 94 to 101 %. © 2023 Elsevier B.V.",
journal = "Journal of Electroanalytical Chemistry",
title = "Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection",
volume = "942",
pages = "117578",
doi = "10.1016/j.jelechem.2023.117578"
}
Haššo, M., Sarakhman, O., Đurđić, S., Stanković, D. M.,& Švorc, L.. (2023). Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection. in Journal of Electroanalytical Chemistry, 942, 117578.
https://doi.org/10.1016/j.jelechem.2023.117578
Haššo M, Sarakhman O, Đurđić S, Stanković DM, Švorc L. Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection. in Journal of Electroanalytical Chemistry. 2023;942:117578.
doi:10.1016/j.jelechem.2023.117578 .
Haššo, Marek, Sarakhman, Olha, Đurđić, Slađana, Stanković, Dalibor M., Švorc, Lubomir, "Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection" in Journal of Electroanalytical Chemistry, 942 (2023):117578,
https://doi.org/10.1016/j.jelechem.2023.117578 . .

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB
 

 

Kompletan repozitorijumGrupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB