Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection
Само за регистроване кориснике
2023
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
In this work, an advanced electrochemical platform was developed for the simple, rapid and sensitive determination of the polyphenolic compound tannic acid in various beverages using the combination of batch injection analysis with amperometric detection on a screen-printed carbon electrode. Several experimental parameters (pH of supporting electrolyte, detection potential, dispensing rate, injected volume, stirring) were consistently evaluated. The most favorable analytical performance in terms of sensitivity, selectivity, repeatability and sampling frequency was obtained in Britton-Robinson buffer pH 5.0 at a detection potential of +0.6 V vs. Ag/AgCl, a dispensing rate of 204 µL/s and an injected volume of 80 µL under stirring condition (1500 r.p.m.). The presented platform has advantages for routine analysis including portable and small-scale experimental setup, low sample consumption (∼100 µL), simple sample preparation (dilution in supporting electrolyte), high sampling frequency ...(180 injections per hour), low limit of detection (80 nM) and suitable precision (RSD = 4.2% for 10 μM tannic acid, n = 20). The applicability of the method was verified by analyzing several beverage samples (tea, wine) in spike-recovery assay with the recovery values for tannic acid ranging from 94 to 101 %. © 2023 Elsevier B.V.
Кључне речи:
Batch injection analysis with amperometric detection / Screen-printed carbon electrode / Tannic acidИзвор:
Journal of Electroanalytical Chemistry, 2023, 942, 117578-Финансирање / пројекти:
- Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200168 (Универзитет у Београду, Хемијски факултет) (RS-MESTD-inst-2020-200168)
- Grant Agency of the Slovak Republic VEGA [1/0159/20]
- bilateral Slovak - Serbian cooperation within the Slovak Research and Development Agency (SK-SRB-21-0019)
- bilateral project Serbia - Slovakia (project number 451-03-43/2022-09/03)
- National Scholarship Programme of the Slovak Republic for the Support of Mobility of Students, PhD Students, University Teachers, Researchers and Artists
Институција/група
VinčaTY - JOUR AU - Haššo, Marek AU - Sarakhman, Olha AU - Đurđić, Slađana AU - Stanković, Dalibor M. AU - Švorc, Lubomir PY - 2023 UR - https://vinar.vin.bg.ac.rs/handle/123456789/11089 AB - In this work, an advanced electrochemical platform was developed for the simple, rapid and sensitive determination of the polyphenolic compound tannic acid in various beverages using the combination of batch injection analysis with amperometric detection on a screen-printed carbon electrode. Several experimental parameters (pH of supporting electrolyte, detection potential, dispensing rate, injected volume, stirring) were consistently evaluated. The most favorable analytical performance in terms of sensitivity, selectivity, repeatability and sampling frequency was obtained in Britton-Robinson buffer pH 5.0 at a detection potential of +0.6 V vs. Ag/AgCl, a dispensing rate of 204 µL/s and an injected volume of 80 µL under stirring condition (1500 r.p.m.). The presented platform has advantages for routine analysis including portable and small-scale experimental setup, low sample consumption (∼100 µL), simple sample preparation (dilution in supporting electrolyte), high sampling frequency (180 injections per hour), low limit of detection (80 nM) and suitable precision (RSD = 4.2% for 10 μM tannic acid, n = 20). The applicability of the method was verified by analyzing several beverage samples (tea, wine) in spike-recovery assay with the recovery values for tannic acid ranging from 94 to 101 %. © 2023 Elsevier B.V. T2 - Journal of Electroanalytical Chemistry T1 - Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection VL - 942 SP - 117578 DO - 10.1016/j.jelechem.2023.117578 ER -
@article{ author = "Haššo, Marek and Sarakhman, Olha and Đurđić, Slađana and Stanković, Dalibor M. and Švorc, Lubomir", year = "2023", abstract = "In this work, an advanced electrochemical platform was developed for the simple, rapid and sensitive determination of the polyphenolic compound tannic acid in various beverages using the combination of batch injection analysis with amperometric detection on a screen-printed carbon electrode. Several experimental parameters (pH of supporting electrolyte, detection potential, dispensing rate, injected volume, stirring) were consistently evaluated. The most favorable analytical performance in terms of sensitivity, selectivity, repeatability and sampling frequency was obtained in Britton-Robinson buffer pH 5.0 at a detection potential of +0.6 V vs. Ag/AgCl, a dispensing rate of 204 µL/s and an injected volume of 80 µL under stirring condition (1500 r.p.m.). The presented platform has advantages for routine analysis including portable and small-scale experimental setup, low sample consumption (∼100 µL), simple sample preparation (dilution in supporting electrolyte), high sampling frequency (180 injections per hour), low limit of detection (80 nM) and suitable precision (RSD = 4.2% for 10 μM tannic acid, n = 20). The applicability of the method was verified by analyzing several beverage samples (tea, wine) in spike-recovery assay with the recovery values for tannic acid ranging from 94 to 101 %. © 2023 Elsevier B.V.", journal = "Journal of Electroanalytical Chemistry", title = "Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection", volume = "942", pages = "117578", doi = "10.1016/j.jelechem.2023.117578" }
Haššo, M., Sarakhman, O., Đurđić, S., Stanković, D. M.,& Švorc, L.. (2023). Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection. in Journal of Electroanalytical Chemistry, 942, 117578. https://doi.org/10.1016/j.jelechem.2023.117578
Haššo M, Sarakhman O, Đurđić S, Stanković DM, Švorc L. Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection. in Journal of Electroanalytical Chemistry. 2023;942:117578. doi:10.1016/j.jelechem.2023.117578 .
Haššo, Marek, Sarakhman, Olha, Đurđić, Slađana, Stanković, Dalibor M., Švorc, Lubomir, "Advanced electrochemical platform for simple and rapid quantification of tannic acid in beverages using batch injection analysis with amperometric detection" in Journal of Electroanalytical Chemistry, 942 (2023):117578, https://doi.org/10.1016/j.jelechem.2023.117578 . .