Prikaz osnovnih podataka o dokumentu

dc.creatorDomienik-Andrzejewska, Joanna
dc.creatorCiraj-Bjelac, Olivera
dc.creatorAskounis, Panagiotis
dc.creatorCovens, Peter
dc.creatorDragusin, Octavian
dc.creatorJacob, Sophie
dc.creatorFarah, Jad
dc.creatorGianicolo, Emilio
dc.creatorPadovani, Renato
dc.creatorTeles, Pedro
dc.creatorWidmark, Anders
dc.creatorStruelens, Lara
dc.date.accessioned2018-07-23T11:31:32Z
dc.date.available2018-07-23T11:31:32Z
dc.date.issued2018
dc.identifier.issn0952-4746
dc.identifier.issn1361-6498
dc.identifier.urihttp://stacks.iop.org/0952-4746/38/i=3/a=934?key=crossref.841f3416432180a6c59d9cdaf3af811f
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/7775
dc.description.abstractThis paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.en
dc.rightsrestrictedAccess
dc.sourceJournal of Radiological Protection
dc.subjectaccess routesen
dc.subjectfluoroscopyen
dc.subjectinterventional cardiologyen
dc.subjectradiation protectionen
dc.subjectwork practice of interventional cardiologistsen
dc.titlePast and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens—results of the EURALOC studyen
dc.typearticleen
dc.rights.licenseARR
dcterms.abstractФарах, Јад; Wидмарк, Aндерс; Телес, Педро; Падовани, Ренато; Гианицоло, Емилио; Јацоб, Сопхие; Драгусин, Оцтавиан; Цовенс, Петер; Aскоунис, Панагиотис; Струеленс, Лара; Домиеник-Aндрзејеwска, Јоанна; Цирај-Бјелац, Оливера;
dc.rights.holder© 2018 IOP Publishing Ltd
dc.citation.volume38
dc.citation.issue3
dc.citation.spage934
dc.citation.epage950
dc.identifier.wos000435111400002
dc.identifier.doi10.1088/1361-6498/aac64b
dc.citation.rankM22
dc.identifier.pmid29780037
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85052014075


Dokumenti

Thumbnail

Ovaj dokument se pojavljuje u sledećim kolekcijama

Prikaz osnovnih podataka o dokumentu