Influence of the graphene oxide content in the ZnO/GO composite on the selectivity and sensitivity of the electrode for detecting diclofenac in water

Thumbnail
2025
Download 🢃
Conference abstract [PDF] (423.8Kb)
Authors
Nastasić, Ana
Gočanin, Kristina
Aleksić, Katarina
Kraljić Roković, Marijana
Marković, Smilja
Stojković Simatović, Ivana
Conference object (Published version)
Metadata
Show full item record
Abstract
Diclofenac (DCF) is one of the most commonly used pharmaceuticals today. Due to its high consumption, DCF ends up in ecosystems and watercourses, where it becomes a pollutant, endangering the living world. Effective monitoring of contaminant concentrations in water is crucial for ensuring water quality, which can be achieved through electroanalytical methods. The performance of an electrochemical method is critically determined by the surface characteristics of the working electrode. Therefore, composites were designed to modify the surface of the working electrode to improve its properties. In this study, we propose zinc oxide/graphene oxide (ZnO/GO) composites with different weight percentages of GO relative to ZnO (0.005%, 0.01%, and 0.05%) to examine the influence of GO content on the characteristics of the electrode for the detection of DCF in water. The physicochemical characteristics of the materials were examined by X-ray diffraction analysis, Raman spectroscopy, and FESEM imag...ing. The materials were then combined with the carbon additive, distilled water, and ethanol into an ink to modify the glassy carbon electrode. After In Situ electrochemical reduction of GO, the obtained electrodes were tested for the oxidation of DCF in a neutral electrolyte (0.1 M phosphate buffer) by cyclic voltammetry (CV). CVs showed an irreversible anodic peak originating from the oxidation of DCF, as well as anodic and cathodic peaks originating from the oxidation/reduction of the decomposition product of the oxidized form of DCF. Parameters such as limit of detection (LOD), limit of quantification (LOQ), dynamic range, and sensitivity were evaluated. The measurements indicated that all electrodes are selective for DCF. The proposed materials are suitable for further investigation in the field of electrochemical detection of pharmaceuticals in aqueous electrolytes.

Source:
Twenty-Third Young Researchers' Conference Materials Science and Engineering : Program and the Book of Abstracts, 2025, 63-63
Publisher:
  • Belgrade : Institute of Technical Sciences of SASA
Funding / projects:
  • Ministry of Science, Technological Development and Innovation of the Republic of Serbia, institutional funding - 200017 (University of Belgrade, Institute of Nuclear Sciences 'Vinča', Belgrade-Vinča) (RS-MESTD-inst-2020-200017)
  • Ministry of Science, Technological Development and Innovation of the Republic of Serbia, institutional funding - 200175 (Institute of Technical Sciences of SASA, Belgrade) (RS-MESTD-inst-2020-200175)
  • Ministry of Science, Technological Development and Innovation of the Republic of Serbia, institutional funding - 200146 (University of Belgrade, Faculty of Physical Chemistry) (RS-MESTD-inst-2020-200146)
  • WaPoDe - Water pollutants detection by ZnO-modified electrochemical sensors: From computational modeling via electrochemical testing to realsystem application (RS-ScienceFundRS-Prizma2023_PM-7377)
Note:
  • Twenty-Third Young Researchers' Conference Materials Science and Engineering, December 3-5, 2025, Belgrade, Serbia.

ISBN: 978-86-80321-40-0

[ Google Scholar ]
Handle
https://hdl.handle.net/21.15107/rcub_vinar_15925
URI
https://vinar.vin.bg.ac.rs/handle/123456789/15925
Collections
  • Radovi istraživača
  • WaPoDe
Institution/Community
Vinča
TY  - CONF
AU  - Nastasić, Ana
AU  - Gočanin, Kristina
AU  - Aleksić, Katarina
AU  - Kraljić Roković, Marijana
AU  - Marković, Smilja
AU  - Stojković Simatović, Ivana
PY  - 2025
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/15925
AB  - Diclofenac (DCF) is one of the most commonly used pharmaceuticals today. Due to its high consumption, DCF ends up in ecosystems and watercourses, where it becomes a pollutant, endangering the living world. Effective monitoring of contaminant concentrations in water is crucial for ensuring water quality, which can be achieved through electroanalytical methods. The performance of an electrochemical method is critically determined by the surface characteristics of the working electrode. Therefore, composites were designed to modify the surface of the working electrode to improve its properties. In this study, we propose zinc oxide/graphene oxide (ZnO/GO) composites with different weight percentages of GO relative to ZnO (0.005%, 0.01%, and 0.05%) to examine the influence of GO content on the characteristics of the electrode for the detection of DCF in water. The physicochemical characteristics of the materials were examined by X-ray diffraction analysis, Raman spectroscopy, and FESEM imaging. The materials were then combined with the carbon additive, distilled water, and ethanol into an ink to modify the glassy carbon electrode. After In Situ electrochemical reduction of GO, the obtained electrodes were tested for the oxidation of DCF in a neutral electrolyte (0.1 M phosphate buffer) by cyclic voltammetry (CV). CVs showed an irreversible anodic peak originating from the oxidation of DCF, as well as anodic and cathodic peaks originating from the oxidation/reduction of the decomposition product of the oxidized form of DCF. Parameters such as limit of detection (LOD), limit of quantification (LOQ), dynamic range, and sensitivity were evaluated. The measurements indicated that all electrodes are selective for DCF. The proposed materials are suitable for further investigation in the field of electrochemical detection of pharmaceuticals in aqueous electrolytes.
PB  - Belgrade : Institute of Technical Sciences of SASA
C3  - Twenty-Third Young Researchers' Conference Materials Science and Engineering : Program and the Book of Abstracts
T1  - Influence of the graphene oxide content in the ZnO/GO composite on the selectivity and sensitivity of the electrode for detecting diclofenac in water
SP  - 63
EP  - 63
UR  - https://hdl.handle.net/21.15107/rcub_vinar_15925
ER  - 
@conference{
author = "Nastasić, Ana and Gočanin, Kristina and Aleksić, Katarina and Kraljić Roković, Marijana and Marković, Smilja and Stojković Simatović, Ivana",
year = "2025",
abstract = "Diclofenac (DCF) is one of the most commonly used pharmaceuticals today. Due to its high consumption, DCF ends up in ecosystems and watercourses, where it becomes a pollutant, endangering the living world. Effective monitoring of contaminant concentrations in water is crucial for ensuring water quality, which can be achieved through electroanalytical methods. The performance of an electrochemical method is critically determined by the surface characteristics of the working electrode. Therefore, composites were designed to modify the surface of the working electrode to improve its properties. In this study, we propose zinc oxide/graphene oxide (ZnO/GO) composites with different weight percentages of GO relative to ZnO (0.005%, 0.01%, and 0.05%) to examine the influence of GO content on the characteristics of the electrode for the detection of DCF in water. The physicochemical characteristics of the materials were examined by X-ray diffraction analysis, Raman spectroscopy, and FESEM imaging. The materials were then combined with the carbon additive, distilled water, and ethanol into an ink to modify the glassy carbon electrode. After In Situ electrochemical reduction of GO, the obtained electrodes were tested for the oxidation of DCF in a neutral electrolyte (0.1 M phosphate buffer) by cyclic voltammetry (CV). CVs showed an irreversible anodic peak originating from the oxidation of DCF, as well as anodic and cathodic peaks originating from the oxidation/reduction of the decomposition product of the oxidized form of DCF. Parameters such as limit of detection (LOD), limit of quantification (LOQ), dynamic range, and sensitivity were evaluated. The measurements indicated that all electrodes are selective for DCF. The proposed materials are suitable for further investigation in the field of electrochemical detection of pharmaceuticals in aqueous electrolytes.",
publisher = "Belgrade : Institute of Technical Sciences of SASA",
journal = "Twenty-Third Young Researchers' Conference Materials Science and Engineering : Program and the Book of Abstracts",
title = "Influence of the graphene oxide content in the ZnO/GO composite on the selectivity and sensitivity of the electrode for detecting diclofenac in water",
pages = "63-63",
url = "https://hdl.handle.net/21.15107/rcub_vinar_15925"
}
Nastasić, A., Gočanin, K., Aleksić, K., Kraljić Roković, M., Marković, S.,& Stojković Simatović, I.. (2025). Influence of the graphene oxide content in the ZnO/GO composite on the selectivity and sensitivity of the electrode for detecting diclofenac in water. in Twenty-Third Young Researchers' Conference Materials Science and Engineering : Program and the Book of Abstracts
Belgrade : Institute of Technical Sciences of SASA., 63-63.
https://hdl.handle.net/21.15107/rcub_vinar_15925
Nastasić A, Gočanin K, Aleksić K, Kraljić Roković M, Marković S, Stojković Simatović I. Influence of the graphene oxide content in the ZnO/GO composite on the selectivity and sensitivity of the electrode for detecting diclofenac in water. in Twenty-Third Young Researchers' Conference Materials Science and Engineering : Program and the Book of Abstracts. 2025;:63-63.
https://hdl.handle.net/21.15107/rcub_vinar_15925 .
Nastasić, Ana, Gočanin, Kristina, Aleksić, Katarina, Kraljić Roković, Marijana, Marković, Smilja, Stojković Simatović, Ivana, "Influence of the graphene oxide content in the ZnO/GO composite on the selectivity and sensitivity of the electrode for detecting diclofenac in water" in Twenty-Third Young Researchers' Conference Materials Science and Engineering : Program and the Book of Abstracts (2025):63-63,
https://hdl.handle.net/21.15107/rcub_vinar_15925 .

DSpace software copyright © 2002-2015  DuraSpace
About the VinaR Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the VinaR Repository | Send Feedback

re3dataOpenAIRERCUB