Sensor Fusion in Luminescence Thermometry: A Path to Higher Precision and Broader Applicability
Authorized Users Only
2025
Authors
Ćirić, Aleksandar
Ristić, Zoran
Gavrilović, Tamara V.
Periša, Jovana
Medić, Mina
Milićević, Bojana R.
Dramićanin, Miroslav
Article (Published version)

Metadata
Show full item recordAbstract
Advancing measurement precision and extending the temperature range are key goals in luminescence thermometry. Traditional single-parameter methods often underperform. Sensor fusion (SF), a statistical tool widely used in fields like autonomous vehicles and medical imaging, is applied to luminescent thermometry by combining multiple sensor probes or treating each temperature-dependent parameter as a separate sensor. This approach consistently enhances precision and extends the temperature range, with fused precision equaling the sum of individual precisions. SF using inverse variance weighting surpasses traditional linear regression models due to its adaptability, achieving maximum performance with any sensor material. It works with both time-resolved and steady-state readouts, using single or multiple excitation sources. Computer simulations and experiments validate this method. For Sm2+, combining lifetime and intensity ratio measurements significantly improves precision across the e...ntire range. Fusion of Mn4+, Ho3+, and Cr3+ lifetimes expands the temperature range to 300–650 K. For Yb3+/Er3+ upconversion green and red emission lifetimes, precision improves across all temperatures. However, Mn5+ shows limited improvement due to the dominance of precision in line-shift measurements, highlighting a limitation of the approach. Overall, SF demonstrates its potential to revolutionize luminescence thermometry by enhancing precision and usability across diverse conditions. © 2025 Wiley-VCH GmbH.
Keywords:
luminescence intensity ratio / luminescence lifetime / measurement uncertainty / sensing precision / sensor fusionSource:
Laser and Photonics Reviews, 2025, 19, 22, e00781-Funding / projects:
- Ministry of Science, Technological Development and Innovation of the Republic of Serbia, institutional funding - 200017 (University of Belgrade, Institute of Nuclear Sciences 'Vinča', Belgrade-Vinča) (RS-MESTD-inst-2020-200017)
- REMTES - Technology for Remote Temperature Measurements in Microfluidic Devices (RS-ScienceFundRS-Prizma2023_TT-7017)
Collections
Institution/Community
VinčaTY - JOUR AU - Ćirić, Aleksandar AU - Ristić, Zoran AU - Gavrilović, Tamara V. AU - Periša, Jovana AU - Medić, Mina AU - Milićević, Bojana R. AU - Dramićanin, Miroslav PY - 2025 UR - https://vinar.vin.bg.ac.rs/handle/123456789/15137 AB - Advancing measurement precision and extending the temperature range are key goals in luminescence thermometry. Traditional single-parameter methods often underperform. Sensor fusion (SF), a statistical tool widely used in fields like autonomous vehicles and medical imaging, is applied to luminescent thermometry by combining multiple sensor probes or treating each temperature-dependent parameter as a separate sensor. This approach consistently enhances precision and extends the temperature range, with fused precision equaling the sum of individual precisions. SF using inverse variance weighting surpasses traditional linear regression models due to its adaptability, achieving maximum performance with any sensor material. It works with both time-resolved and steady-state readouts, using single or multiple excitation sources. Computer simulations and experiments validate this method. For Sm2+, combining lifetime and intensity ratio measurements significantly improves precision across the entire range. Fusion of Mn4+, Ho3+, and Cr3+ lifetimes expands the temperature range to 300–650 K. For Yb3+/Er3+ upconversion green and red emission lifetimes, precision improves across all temperatures. However, Mn5+ shows limited improvement due to the dominance of precision in line-shift measurements, highlighting a limitation of the approach. Overall, SF demonstrates its potential to revolutionize luminescence thermometry by enhancing precision and usability across diverse conditions. © 2025 Wiley-VCH GmbH. T2 - Laser and Photonics Reviews T1 - Sensor Fusion in Luminescence Thermometry: A Path to Higher Precision and Broader Applicability VL - 19 IS - 22 SP - e00781 DO - 10.1002/lpor.202500781 ER -
@article{
author = "Ćirić, Aleksandar and Ristić, Zoran and Gavrilović, Tamara V. and Periša, Jovana and Medić, Mina and Milićević, Bojana R. and Dramićanin, Miroslav",
year = "2025",
abstract = "Advancing measurement precision and extending the temperature range are key goals in luminescence thermometry. Traditional single-parameter methods often underperform. Sensor fusion (SF), a statistical tool widely used in fields like autonomous vehicles and medical imaging, is applied to luminescent thermometry by combining multiple sensor probes or treating each temperature-dependent parameter as a separate sensor. This approach consistently enhances precision and extends the temperature range, with fused precision equaling the sum of individual precisions. SF using inverse variance weighting surpasses traditional linear regression models due to its adaptability, achieving maximum performance with any sensor material. It works with both time-resolved and steady-state readouts, using single or multiple excitation sources. Computer simulations and experiments validate this method. For Sm2+, combining lifetime and intensity ratio measurements significantly improves precision across the entire range. Fusion of Mn4+, Ho3+, and Cr3+ lifetimes expands the temperature range to 300–650 K. For Yb3+/Er3+ upconversion green and red emission lifetimes, precision improves across all temperatures. However, Mn5+ shows limited improvement due to the dominance of precision in line-shift measurements, highlighting a limitation of the approach. Overall, SF demonstrates its potential to revolutionize luminescence thermometry by enhancing precision and usability across diverse conditions. © 2025 Wiley-VCH GmbH.",
journal = "Laser and Photonics Reviews",
title = "Sensor Fusion in Luminescence Thermometry: A Path to Higher Precision and Broader Applicability",
volume = "19",
number = "22",
pages = "e00781",
doi = "10.1002/lpor.202500781"
}
Ćirić, A., Ristić, Z., Gavrilović, T. V., Periša, J., Medić, M., Milićević, B. R.,& Dramićanin, M.. (2025). Sensor Fusion in Luminescence Thermometry: A Path to Higher Precision and Broader Applicability. in Laser and Photonics Reviews, 19(22), e00781. https://doi.org/10.1002/lpor.202500781
Ćirić A, Ristić Z, Gavrilović TV, Periša J, Medić M, Milićević BR, Dramićanin M. Sensor Fusion in Luminescence Thermometry: A Path to Higher Precision and Broader Applicability. in Laser and Photonics Reviews. 2025;19(22):e00781. doi:10.1002/lpor.202500781 .
Ćirić, Aleksandar, Ristić, Zoran, Gavrilović, Tamara V., Periša, Jovana, Medić, Mina, Milićević, Bojana R., Dramićanin, Miroslav, "Sensor Fusion in Luminescence Thermometry: A Path to Higher Precision and Broader Applicability" in Laser and Photonics Reviews, 19, no. 22 (2025):e00781, https://doi.org/10.1002/lpor.202500781 . .
