Determining the PM10 Pollution Sources near the Copper Smelter in Bor, Serbia †

Thumbnail
2024
Preuzimanje 🢃
Main article [PDF] (7.549Mb)
Autori
Kovačević, Renata
Radović, Bojan
Manojlović, Dragan
Urošević, Tamara
Apostolovski-Trujić, Tatjana
Tasić, Viša
Jovašević-Stojanović, Milena
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
The EPA Positive Matrix Factorization (PMF) 5.0 model was applied to determine the sources and characteristics of PM10 collected near the copper smelter in Bor, Serbia, from September 2009 to July 2010. For a better understanding of the industrial sources of PM10 pollution, the dataset was divided into four observation periods: heating season (HS), non-heating season (NHS), copper smelter in work (SW), and copper smelter out of work (SOW). The daily limit for the PM10 fraction of 50 μg/m3 was exceeded on one-sixth of days in the NHS, about half the days in the HS, and about one-third of days during the SOW and SW period. The nine different sources of PM10 were identified: fuel combustion, industrial dust, dust from tailings, storage and preparation of raw materials, secondary nitrate, Cu smelter, traffic, cadmium, and plant for the production of precious metals. The contribution of factors related to the activities in the copper smelter complex to the total mass of PM10 was 83.1%. When... the copper smelter was out of work the contribution of all the factors related to PM10 pollution from the copper smelter to the total mass of the PM10 was 2.3-fold lower, 35.8%, compared with the period when the copper smelter was in work. This study is the first attempt to use PMF receptor modeling to determine the air pollution sources and their contribution to ambient air pollution in the city of Bor, Serbia. © 2024 by the authors.

Ključne reči:
air pollution / arsenic / copper smelter / heavy metals / mining / particulate matter
Izvor:
Atmosphere, 2024, 15, 12, 1498-
Finansiranje / projekti:
  • 2023-07-17 WeBaSOOP - Research Reinforcing in the Western Balkans in Offline and Online Monitoring and Source Identification of Atmospheric Particles (EU-HE-CSA-101060170)
  • Ministarstvo nauke, tehnološkog razvoja i inovacija Republike Srbije, institucionalno finansiranje - 200052 (Institut za rudarstvo i metalurgiju, Bor) (RS-MESTD-inst-2020-200052)
  • Ministarstvo nauke, tehnološkog razvoja i inovacija Republike Srbije, institucionalno finansiranje - 200017 (Univerzitet u Beogradu, Institut za nuklearne nauke Vinča, Beograd-Vinča) (RS-MESTD-inst-2020-200017)

DOI: 10.3390/atmos15121498

ISSN: 2073-4433

Scopus: 2-s2.0-85213210260
[ Google Scholar ]
URI
https://vinar.vin.bg.ac.rs/handle/123456789/14190
Kolekcije
  • Radovi istraživača
  • WeBaSOOP
Institucija/grupa
Vinča
TY  - JOUR
AU  - Kovačević, Renata
AU  - Radović, Bojan
AU  - Manojlović, Dragan
AU  - Urošević, Tamara
AU  - Apostolovski-Trujić, Tatjana
AU  - Tasić, Viša
AU  - Jovašević-Stojanović, Milena
PY  - 2024
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/14190
AB  - The EPA Positive Matrix Factorization (PMF) 5.0 model was applied to determine the sources and characteristics of PM10 collected near the copper smelter in Bor, Serbia, from September 2009 to July 2010. For a better understanding of the industrial sources of PM10 pollution, the dataset was divided into four observation periods: heating season (HS), non-heating season (NHS), copper smelter in work (SW), and copper smelter out of work (SOW). The daily limit for the PM10 fraction of 50 μg/m3 was exceeded on one-sixth of days in the NHS, about half the days in the HS, and about one-third of days during the SOW and SW period. The nine different sources of PM10 were identified: fuel combustion, industrial dust, dust from tailings, storage and preparation of raw materials, secondary nitrate, Cu smelter, traffic, cadmium, and plant for the production of precious metals. The contribution of factors related to the activities in the copper smelter complex to the total mass of PM10 was 83.1%. When the copper smelter was out of work the contribution of all the factors related to PM10 pollution from the copper smelter to the total mass of the PM10 was 2.3-fold lower, 35.8%, compared with the period when the copper smelter was in work. This study is the first attempt to use PMF receptor modeling to determine the air pollution sources and their contribution to ambient air pollution in the city of Bor, Serbia. © 2024 by the authors.
T2  - Atmosphere
T1  - Determining the PM10 Pollution Sources near the Copper Smelter in Bor, Serbia †
VL  - 15
IS  - 12
SP  - 1498
DO  - 10.3390/atmos15121498
ER  - 
@article{
author = "Kovačević, Renata and Radović, Bojan and Manojlović, Dragan and Urošević, Tamara and Apostolovski-Trujić, Tatjana and Tasić, Viša and Jovašević-Stojanović, Milena",
year = "2024",
abstract = "The EPA Positive Matrix Factorization (PMF) 5.0 model was applied to determine the sources and characteristics of PM10 collected near the copper smelter in Bor, Serbia, from September 2009 to July 2010. For a better understanding of the industrial sources of PM10 pollution, the dataset was divided into four observation periods: heating season (HS), non-heating season (NHS), copper smelter in work (SW), and copper smelter out of work (SOW). The daily limit for the PM10 fraction of 50 μg/m3 was exceeded on one-sixth of days in the NHS, about half the days in the HS, and about one-third of days during the SOW and SW period. The nine different sources of PM10 were identified: fuel combustion, industrial dust, dust from tailings, storage and preparation of raw materials, secondary nitrate, Cu smelter, traffic, cadmium, and plant for the production of precious metals. The contribution of factors related to the activities in the copper smelter complex to the total mass of PM10 was 83.1%. When the copper smelter was out of work the contribution of all the factors related to PM10 pollution from the copper smelter to the total mass of the PM10 was 2.3-fold lower, 35.8%, compared with the period when the copper smelter was in work. This study is the first attempt to use PMF receptor modeling to determine the air pollution sources and their contribution to ambient air pollution in the city of Bor, Serbia. © 2024 by the authors.",
journal = "Atmosphere",
title = "Determining the PM10 Pollution Sources near the Copper Smelter in Bor, Serbia †",
volume = "15",
number = "12",
pages = "1498",
doi = "10.3390/atmos15121498"
}
Kovačević, R., Radović, B., Manojlović, D., Urošević, T., Apostolovski-Trujić, T., Tasić, V.,& Jovašević-Stojanović, M.. (2024). Determining the PM10 Pollution Sources near the Copper Smelter in Bor, Serbia †. in Atmosphere, 15(12), 1498.
https://doi.org/10.3390/atmos15121498
Kovačević R, Radović B, Manojlović D, Urošević T, Apostolovski-Trujić T, Tasić V, Jovašević-Stojanović M. Determining the PM10 Pollution Sources near the Copper Smelter in Bor, Serbia †. in Atmosphere. 2024;15(12):1498.
doi:10.3390/atmos15121498 .
Kovačević, Renata, Radović, Bojan, Manojlović, Dragan, Urošević, Tamara, Apostolovski-Trujić, Tatjana, Tasić, Viša, Jovašević-Stojanović, Milena, "Determining the PM10 Pollution Sources near the Copper Smelter in Bor, Serbia †" in Atmosphere, 15, no. 12 (2024):1498,
https://doi.org/10.3390/atmos15121498 . .

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB
 

 

Kompletan repozitorijumGrupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB