Readout Methods to Enhance the Performance of Luminescence Thermometers

Thumbnail
2024
Preuzimanje 🢃
Main article [PDF] (3.128Mb)
Autori
Dramićanin, Miroslav
Alodhayb, Abdullah N.
Ćirić, Aleksandar
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
Over the past three decades, luminescence thermometry has gained significant attention among researchers and practitioners. The method has progressed in terms of utilizing temperature-sensitive luminescent materials, obtaining temperature read-outs from luminescence, developing applications, and improving performance. This paper reviews and critically analyzes routes for improving luminescence thermometry performance, in particular the sensitivity, accuracy, and precision of the method. These include the use of highly temperature-sensitive probes, temperature read-outs from luminescence with improved sensitivity, multiparameter temperature-reading methods, the applications of principal component analysis and artificial neural networks, and sensor fusion. © 2024 by the authors.
Ključne reči:
artificial neural networks / luminescence / luminescence thermometry / phosphor thermometry / sensor fusion
Izvor:
Condensed Matter, 2024, 9, 4, 46-
Finansiranje / projekti:
  • 2023-07-17 REMTES - Technology for Remote Temperature Measurements in Microfluidic Devices (RS-ScienceFundRS-Prizma2023_TT-7017)
  • Researcher supporting program at King Saud University, Riyadh [RSP2024R328]
  • Ministarstvo nauke, tehnološkog razvoja i inovacija Republike Srbije, institucionalno finansiranje - 200017 (Univerzitet u Beogradu, Institut za nuklearne nauke Vinča, Beograd-Vinča) (RS-MESTD-inst-2020-200017)

DOI: 10.3390/condmat9040046

ISSN: 2410-3896

Scopus: 2-s2.0-85213461598
[ Google Scholar ]
URI
https://vinar.vin.bg.ac.rs/handle/123456789/14182
Kolekcije
  • Radovi istraživača
  • REMTES
Institucija/grupa
Vinča
TY  - JOUR
AU  - Dramićanin, Miroslav
AU  - Alodhayb, Abdullah N.
AU  - Ćirić, Aleksandar
PY  - 2024
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/14182
AB  - Over the past three decades, luminescence thermometry has gained significant attention among researchers and practitioners. The method has progressed in terms of utilizing temperature-sensitive luminescent materials, obtaining temperature read-outs from luminescence, developing applications, and improving performance. This paper reviews and critically analyzes routes for improving luminescence thermometry performance, in particular the sensitivity, accuracy, and precision of the method. These include the use of highly temperature-sensitive probes, temperature read-outs from luminescence with improved sensitivity, multiparameter temperature-reading methods, the applications of principal component analysis and artificial neural networks, and sensor fusion. © 2024 by the authors.
T2  - Condensed Matter
T1  - Readout Methods to Enhance the Performance of Luminescence Thermometers
VL  - 9
IS  - 4
SP  - 46
DO  - 10.3390/condmat9040046
ER  - 
@article{
author = "Dramićanin, Miroslav and Alodhayb, Abdullah N. and Ćirić, Aleksandar",
year = "2024",
abstract = "Over the past three decades, luminescence thermometry has gained significant attention among researchers and practitioners. The method has progressed in terms of utilizing temperature-sensitive luminescent materials, obtaining temperature read-outs from luminescence, developing applications, and improving performance. This paper reviews and critically analyzes routes for improving luminescence thermometry performance, in particular the sensitivity, accuracy, and precision of the method. These include the use of highly temperature-sensitive probes, temperature read-outs from luminescence with improved sensitivity, multiparameter temperature-reading methods, the applications of principal component analysis and artificial neural networks, and sensor fusion. © 2024 by the authors.",
journal = "Condensed Matter",
title = "Readout Methods to Enhance the Performance of Luminescence Thermometers",
volume = "9",
number = "4",
pages = "46",
doi = "10.3390/condmat9040046"
}
Dramićanin, M., Alodhayb, A. N.,& Ćirić, A.. (2024). Readout Methods to Enhance the Performance of Luminescence Thermometers. in Condensed Matter, 9(4), 46.
https://doi.org/10.3390/condmat9040046
Dramićanin M, Alodhayb AN, Ćirić A. Readout Methods to Enhance the Performance of Luminescence Thermometers. in Condensed Matter. 2024;9(4):46.
doi:10.3390/condmat9040046 .
Dramićanin, Miroslav, Alodhayb, Abdullah N., Ćirić, Aleksandar, "Readout Methods to Enhance the Performance of Luminescence Thermometers" in Condensed Matter, 9, no. 4 (2024):46,
https://doi.org/10.3390/condmat9040046 . .

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB
 

 

Kompletan repozitorijumGrupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB