ВинаР - Репозиторијум Института за нуклеарне науке Винча
    • English
    • Српски
    • Српски (Serbia)
  • Српски (ћирилица) 
    • Енглески
    • Српски (ћирилица)
    • Српски (латиница)
  • Пријава
Преглед записа 
  •   ВинаР
  • Vinča
  • Radovi istraživača
  • Преглед записа
  •   ВинаР
  • Vinča
  • Radovi istraživača
  • Преглед записа
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validation of Heart Rate Estimation from Photoplethysmograph and Accelerometer Recordings During Post-Exercise Relaxation

Нема приказа
Аутори
Petrović, Jovana S.
Ivanović, Marija D.
Atanasoski, Vladimir
Lazović, Aleksandar
Tiosavljević, Maša
Tadić, Predrag
Hadžievski, Ljupčo
Ristić, Arsen
Vukčević, Vladan
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
Photoplethysmogrpah and accelerometer hardware have reached the stage at which the sensors are easily affordable and suitable for self-application as well as a part of multiparametric sensing schemes in health monitoring. However, the non-supervised extraction of biomarkers, as simple as heart rate, remains a challenge, largely due to the large variety in pulse shapes and poor signal quality when measured under stress. While a large body of work, including database generation, has been done for signals recorded distally at fingers, wrist, toes and temporal artery, the data recorded at distal arteries such as carotid, are lacking. Here we use the SensSmartTech multiparameter database to test the performance of the PPG and ACC in HR estimation at rest and during relaxation after the activity. PPG was recorded at carotid and brachial arteries and ACC in the vicinity of the precordial V4 electrode. HR is calculated using the available extrema-search functions. Results indicate excellent ag...reement with the reference HR extracted from the ECG signal, with the RMSE on both sensors below 3 bpm. The accuracy of the ACC measurement increased after the activity, while that of the PPG decreased, nevertheless remaining within the above error margin.

Кључне речи:
accelerometer / ECG / heart rate / photoplethysmograph
Извор:
11th International Conference on Electrical, Electronic and Computing Engineering (IcETRAN) : Proceedings, 2024
Издавач:
  • IEEE : Institute of Electrical and Electronics Engineers (IEEE)
Финансирање / пројекти:
  • 2023-07-17 SensSmart - Multi-SENSor SysteM and ARTificial intelligence in service of heart failure diagnosis (RS-ScienceFundRS-Ideje-7754338)
  • Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200017 (Универзитет у Београду, Институт за нуклеарне науке Винча, Београд-Винча) (RS-MESTD-inst-2020-200017)
  • Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200103 (Универзитет у Београду, Електротехнички факултет) (RS-MESTD-inst-2020-200103)
Напомена:
  • 11th International Conference on Electrical, Electronic and Computing Engineering : 03-06 June 2024, Niš.

DOI: 10.1109/IcETRAN62308.2024.10645151

ISBN: 979-8-3503-8699-8

Scopus: 2-s2.0-85204058268
[ Google Scholar ]
URI
https://vinar.vin.bg.ac.rs/handle/123456789/13752
Колекције
  • Radovi istraživača
  • SensSmart
Институција/група
Vinča
TY  - CONF
AU  - Petrović, Jovana S.
AU  - Ivanović, Marija D.
AU  - Atanasoski, Vladimir
AU  - Lazović, Aleksandar
AU  - Tiosavljević, Maša
AU  - Tadić, Predrag
AU  - Hadžievski, Ljupčo
AU  - Ristić, Arsen
AU  - Vukčević, Vladan
PY  - 2024
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/13752
AB  - Photoplethysmogrpah and accelerometer hardware have reached the stage at which the sensors are easily affordable and suitable for self-application as well as a part of multiparametric sensing schemes in health monitoring. However, the non-supervised extraction of biomarkers, as simple as heart rate, remains a challenge, largely due to the large variety in pulse shapes and poor signal quality when measured under stress. While a large body of work, including database generation, has been done for signals recorded distally at fingers, wrist, toes and temporal artery, the data recorded at distal arteries such as carotid, are lacking. Here we use the SensSmartTech multiparameter database to test the performance of the PPG and ACC in HR estimation at rest and during relaxation after the activity. PPG was recorded at carotid and brachial arteries and ACC in the vicinity of the precordial V4 electrode. HR is calculated using the available extrema-search functions. Results indicate excellent agreement with the reference HR extracted from the ECG signal, with the RMSE on both sensors below 3 bpm. The accuracy of the ACC measurement increased after the activity, while that of the PPG decreased, nevertheless remaining within the above error margin.
PB  - IEEE : Institute of Electrical and Electronics Engineers (IEEE)
C3  - 11th International Conference on Electrical, Electronic and Computing Engineering (IcETRAN) : Proceedings
T1  - Validation of Heart Rate Estimation from Photoplethysmograph and Accelerometer Recordings During Post-Exercise Relaxation
DO  - 10.1109/IcETRAN62308.2024.10645151
ER  - 
@conference{
author = "Petrović, Jovana S. and Ivanović, Marija D. and Atanasoski, Vladimir and Lazović, Aleksandar and Tiosavljević, Maša and Tadić, Predrag and Hadžievski, Ljupčo and Ristić, Arsen and Vukčević, Vladan",
year = "2024",
abstract = "Photoplethysmogrpah and accelerometer hardware have reached the stage at which the sensors are easily affordable and suitable for self-application as well as a part of multiparametric sensing schemes in health monitoring. However, the non-supervised extraction of biomarkers, as simple as heart rate, remains a challenge, largely due to the large variety in pulse shapes and poor signal quality when measured under stress. While a large body of work, including database generation, has been done for signals recorded distally at fingers, wrist, toes and temporal artery, the data recorded at distal arteries such as carotid, are lacking. Here we use the SensSmartTech multiparameter database to test the performance of the PPG and ACC in HR estimation at rest and during relaxation after the activity. PPG was recorded at carotid and brachial arteries and ACC in the vicinity of the precordial V4 electrode. HR is calculated using the available extrema-search functions. Results indicate excellent agreement with the reference HR extracted from the ECG signal, with the RMSE on both sensors below 3 bpm. The accuracy of the ACC measurement increased after the activity, while that of the PPG decreased, nevertheless remaining within the above error margin.",
publisher = "IEEE : Institute of Electrical and Electronics Engineers (IEEE)",
journal = "11th International Conference on Electrical, Electronic and Computing Engineering (IcETRAN) : Proceedings",
title = "Validation of Heart Rate Estimation from Photoplethysmograph and Accelerometer Recordings During Post-Exercise Relaxation",
doi = "10.1109/IcETRAN62308.2024.10645151"
}
Petrović, J. S., Ivanović, M. D., Atanasoski, V., Lazović, A., Tiosavljević, M., Tadić, P., Hadžievski, L., Ristić, A.,& Vukčević, V.. (2024). Validation of Heart Rate Estimation from Photoplethysmograph and Accelerometer Recordings During Post-Exercise Relaxation. in 11th International Conference on Electrical, Electronic and Computing Engineering (IcETRAN) : Proceedings
IEEE : Institute of Electrical and Electronics Engineers (IEEE)..
https://doi.org/10.1109/IcETRAN62308.2024.10645151
Petrović JS, Ivanović MD, Atanasoski V, Lazović A, Tiosavljević M, Tadić P, Hadžievski L, Ristić A, Vukčević V. Validation of Heart Rate Estimation from Photoplethysmograph and Accelerometer Recordings During Post-Exercise Relaxation. in 11th International Conference on Electrical, Electronic and Computing Engineering (IcETRAN) : Proceedings. 2024;.
doi:10.1109/IcETRAN62308.2024.10645151 .
Petrović, Jovana S., Ivanović, Marija D., Atanasoski, Vladimir, Lazović, Aleksandar, Tiosavljević, Maša, Tadić, Predrag, Hadžievski, Ljupčo, Ristić, Arsen, Vukčević, Vladan, "Validation of Heart Rate Estimation from Photoplethysmograph and Accelerometer Recordings During Post-Exercise Relaxation" in 11th International Conference on Electrical, Electronic and Computing Engineering (IcETRAN) : Proceedings (2024),
https://doi.org/10.1109/IcETRAN62308.2024.10645151 . .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB