Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory

Thumbnail
2023
Preuzimanje 🢃
Main article [PDF] (2.375Mb)
Autori
Đurđić, Slađana
Vlahović, Filip
Markićević, Milan
Mutić, Jelena
Manojlović, Dragan
Stanković, Vesna
Švorc, Lubomir
Stanković, Dalibor M.
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
Herein, a screen–printed diamond electrode (SPDE) coupled with a “point-of-care” platform (30 µL-drop concepts, single-drop-detection approach) was successfully applied for the electrochemical determination of pterostilbene (PTS). Cyclic voltammetry identified irreversible oxidation of PTS, where oxidation peak was shown to be strongly dependent on the pH of the working environmental. Although the proposition of the detailed electrochemical oxidation mechanism of PTS goes out of the scope of the present research, we have determined the most probable reactive site of our analyte, by utilizing DFT-based reactivity descriptors (Fukui functions). For electrochemical quantification of PTS, oxidation peak at 0.32 V (vs. Ag/AgCl) was followed in presence of 0.5 mol L−1 of Briton–Robinson buffer solution (pH = 9). Coupled with the optimized parameters of differential pulse voltammetry (DPV), SPDE detected PTS in two linear ranges (first range was from 0.011 to 0.912 µmol L−1; second range was ...from 0.912 to 4.420 µmol L−1), providing the LOD and LOQ on a nanomolar level (3.1 nmol L−1 and 10.0 nmol L−1, respectively). The selectivity of the optimized DPV method was found to be excellent, with the current changes of less than 7%, in the presence of ten times higher concentrations of the certain interferences. The practical applicability of the SPDE and single-drop-detection approach in dietary supplements (with a declared PTS content of 50 mg/tablet), with the recovery values ranging from 95 to 102%, shows that the developed method has high potential for precise and accurate PTS detection, as well as exceptional miniaturization possibilities of relevant equipment for on-site sensing.

Ključne reči:
“point-of-care” platform / B3LYP / density functional theory / DFT / dietary supplements / electrochemical determination / Fukui functions / pterostilbene / screen-printed diamond electrode / single-drop-detection approach
Izvor:
Chemosensors, 2023, 11, 1, 15-
Finansiranje / projekti:
  • Ministarstvo nauke, tehnološkog razvoja i inovacija Republike Srbije, institucionalno finansiranje - 200168 (Univerzitet u Beogradu, Hemijski fakultet) (RS-MESTD-inst-2020-200168)
  • Ministarstvo nauke, tehnološkog razvoja i inovacija Republike Srbije, institucionalno finansiranje - 200026 (Univerzitet u Beogradu, Institut za hemiju, tehnologiju i metalurgiju - IHTM) (RS-MESTD-inst-2020-200026)
  • E! 13303 MED-BIO-TEST [Ministry of Education, Science and Technological Development of Republic of Serbia (contract number 451-03-00053/2020-09/2/2)]
  • Grant Agency of the Slovak Republic [VEGA No. 1/0159/20]
  • Bilateral Slovak-Serbian [SK-SRB-21-0019]

DOI: 10.3390/chemosensors11010015

ISSN: 2227-9040

WoS: 000917003600001

Scopus: 2-s2.0-85146777248
[ Google Scholar ]
5
4
URI
https://vinar.vin.bg.ac.rs/handle/123456789/10618
Kolekcije
  • 070 - Laboratorija za radioizotope
  • Radovi istraživača
Institucija/grupa
Vinča
TY  - JOUR
AU  - Đurđić, Slađana
AU  - Vlahović, Filip
AU  - Markićević, Milan
AU  - Mutić, Jelena
AU  - Manojlović, Dragan
AU  - Stanković, Vesna
AU  - Švorc, Lubomir
AU  - Stanković, Dalibor M.
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10618
AB  - Herein, a screen–printed diamond electrode (SPDE) coupled with a “point-of-care” platform (30 µL-drop concepts, single-drop-detection approach) was successfully applied for the electrochemical determination of pterostilbene (PTS). Cyclic voltammetry identified irreversible oxidation of PTS, where oxidation peak was shown to be strongly dependent on the pH of the working environmental. Although the proposition of the detailed electrochemical oxidation mechanism of PTS goes out of the scope of the present research, we have determined the most probable reactive site of our analyte, by utilizing DFT-based reactivity descriptors (Fukui functions). For electrochemical quantification of PTS, oxidation peak at 0.32 V (vs. Ag/AgCl) was followed in presence of 0.5 mol L−1 of Briton–Robinson buffer solution (pH = 9). Coupled with the optimized parameters of differential pulse voltammetry (DPV), SPDE detected PTS in two linear ranges (first range was from 0.011 to 0.912 µmol L−1; second range was from 0.912 to 4.420 µmol L−1), providing the LOD and LOQ on a nanomolar level (3.1 nmol L−1 and 10.0 nmol L−1, respectively). The selectivity of the optimized DPV method was found to be excellent, with the current changes of less than 7%, in the presence of ten times higher concentrations of the certain interferences. The practical applicability of the SPDE and single-drop-detection approach in dietary supplements (with a declared PTS content of 50 mg/tablet), with the recovery values ranging from 95 to 102%, shows that the developed method has high potential for precise and accurate PTS detection, as well as exceptional miniaturization possibilities of relevant equipment for on-site sensing.
T2  - Chemosensors
T1  - Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory
VL  - 11
IS  - 1
SP  - 15
DO  - 10.3390/chemosensors11010015
ER  - 
@article{
author = "Đurđić, Slađana and Vlahović, Filip and Markićević, Milan and Mutić, Jelena and Manojlović, Dragan and Stanković, Vesna and Švorc, Lubomir and Stanković, Dalibor M.",
year = "2023",
abstract = "Herein, a screen–printed diamond electrode (SPDE) coupled with a “point-of-care” platform (30 µL-drop concepts, single-drop-detection approach) was successfully applied for the electrochemical determination of pterostilbene (PTS). Cyclic voltammetry identified irreversible oxidation of PTS, where oxidation peak was shown to be strongly dependent on the pH of the working environmental. Although the proposition of the detailed electrochemical oxidation mechanism of PTS goes out of the scope of the present research, we have determined the most probable reactive site of our analyte, by utilizing DFT-based reactivity descriptors (Fukui functions). For electrochemical quantification of PTS, oxidation peak at 0.32 V (vs. Ag/AgCl) was followed in presence of 0.5 mol L−1 of Briton–Robinson buffer solution (pH = 9). Coupled with the optimized parameters of differential pulse voltammetry (DPV), SPDE detected PTS in two linear ranges (first range was from 0.011 to 0.912 µmol L−1; second range was from 0.912 to 4.420 µmol L−1), providing the LOD and LOQ on a nanomolar level (3.1 nmol L−1 and 10.0 nmol L−1, respectively). The selectivity of the optimized DPV method was found to be excellent, with the current changes of less than 7%, in the presence of ten times higher concentrations of the certain interferences. The practical applicability of the SPDE and single-drop-detection approach in dietary supplements (with a declared PTS content of 50 mg/tablet), with the recovery values ranging from 95 to 102%, shows that the developed method has high potential for precise and accurate PTS detection, as well as exceptional miniaturization possibilities of relevant equipment for on-site sensing.",
journal = "Chemosensors",
title = "Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory",
volume = "11",
number = "1",
pages = "15",
doi = "10.3390/chemosensors11010015"
}
Đurđić, S., Vlahović, F., Markićević, M., Mutić, J., Manojlović, D., Stanković, V., Švorc, L.,& Stanković, D. M.. (2023). Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory. in Chemosensors, 11(1), 15.
https://doi.org/10.3390/chemosensors11010015
Đurđić S, Vlahović F, Markićević M, Mutić J, Manojlović D, Stanković V, Švorc L, Stanković DM. Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory. in Chemosensors. 2023;11(1):15.
doi:10.3390/chemosensors11010015 .
Đurđić, Slađana, Vlahović, Filip, Markićević, Milan, Mutić, Jelena, Manojlović, Dragan, Stanković, Vesna, Švorc, Lubomir, Stanković, Dalibor M., "Application of Screen Printed Diamond Electrode, Coupled with “Point-of-Care” Platform, for Nanomolar Quantification of Phytonutrient Pterostilbene in Dietary Supplements: An Experimental Study Supported by Theory" in Chemosensors, 11, no. 1 (2023):15,
https://doi.org/10.3390/chemosensors11010015 . .

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB
 

 

Kompletan repozitorijumGrupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu VinaR | Pošaljite zapažanja

re3dataOpenAIRERCUB