VinaR - Repozitorijum Instituta za nuklearne nauke Vinča
    • English
    • Српски
    • Српски (Serbia)
  • Srpski (latinica) 
    • Engleski
    • Srpski (ćirilica)
    • Srpski (latinica)
  • Prijava
Pregled zapisa 
  •   VinaR
  • Vinča
  • Radovi istraživača
  • Pregled zapisa
  •   VinaR
  • Vinča
  • Radovi istraživača
  • Pregled zapisa
JavaScript is disabled for your browser. Some features of this site may not work without it.

Systematic uncertainties in integrated luminosity measurement at CEPC

Thumbnail
2022
Preuzimanje 🢃
Main article [PDF] (2.736Mb)
Autori
Smiljanić, Ivan
Božović-Jelisavčić, Ivanka
Kačarević, Goran
Vukašinović, Nataša
Vidaković, Ivana
Reković, Vladimir
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
The very forward region is one of the most challenging regions to instrument at a future e + e - collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams. © 2022 IOP Publishing Ltd and Sissa Medialab.
Ključne reči:
Analysis and statistical methods / Large detector-systems performance / Performance of High Energy Physics Detectors / Simulation methods and programs
Izvor:
Journal of Instrumentation, 2022, 17, 9
Finansiranje / projekti:
  • 2023-07-17 HIGHTONE-P - HIGGS boson: A portal to new physics (RS-ScienceFundRS-Ideje-7699827)
Napomena:
  • Erratum: https://vinar.vin.bg.ac.rs/handle/123456789/10567
Povezane informacije:
  • Povezani sadržaj
    https://vinar.vin.bg.ac.rs/handle/123456789/10567

DOI: 10.1088/1748-0221/17/09/P09014

ISSN: 1748-0221

WoS: 000898634000008

Scopus: 2-s2.0-85141549124
[ Google Scholar ]
2
2
URI
https://vinar.vin.bg.ac.rs/handle/123456789/10566
Kolekcije
  • Radovi istraživača
  • HIGHTONE-P
Institucija/grupa
Vinča
TY  - JOUR
AU  - Smiljanić, Ivan
AU  - Božović-Jelisavčić, Ivanka
AU  - Kačarević, Goran
AU  - Vukašinović, Nataša
AU  - Vidaković, Ivana
AU  - Reković, Vladimir
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10566
AB  - The very forward region is one of the most challenging regions to instrument at a future e + e - collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams. © 2022 IOP Publishing Ltd and Sissa Medialab.
T2  - Journal of Instrumentation
T1  - Systematic uncertainties in integrated luminosity measurement at CEPC
VL  - 17
IS  - 9
DO  - 10.1088/1748-0221/17/09/P09014
ER  - 
@article{
author = "Smiljanić, Ivan and Božović-Jelisavčić, Ivanka and Kačarević, Goran and Vukašinović, Nataša and Vidaković, Ivana and Reković, Vladimir",
year = "2022",
abstract = "The very forward region is one of the most challenging regions to instrument at a future e + e - collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams. © 2022 IOP Publishing Ltd and Sissa Medialab.",
journal = "Journal of Instrumentation",
title = "Systematic uncertainties in integrated luminosity measurement at CEPC",
volume = "17",
number = "9",
doi = "10.1088/1748-0221/17/09/P09014"
}
Smiljanić, I., Božović-Jelisavčić, I., Kačarević, G., Vukašinović, N., Vidaković, I.,& Reković, V.. (2022). Systematic uncertainties in integrated luminosity measurement at CEPC. in Journal of Instrumentation, 17(9).
https://doi.org/10.1088/1748-0221/17/09/P09014
Smiljanić I, Božović-Jelisavčić I, Kačarević G, Vukašinović N, Vidaković I, Reković V. Systematic uncertainties in integrated luminosity measurement at CEPC. in Journal of Instrumentation. 2022;17(9).
doi:10.1088/1748-0221/17/09/P09014 .
Smiljanić, Ivan, Božović-Jelisavčić, Ivanka, Kačarević, Goran, Vukašinović, Nataša, Vidaković, Ivana, Reković, Vladimir, "Systematic uncertainties in integrated luminosity measurement at CEPC" in Journal of Instrumentation, 17, no. 9 (2022),
https://doi.org/10.1088/1748-0221/17/09/P09014 . .

DSpace software copyright © 2002-2015  DuraSpace