Претраживање
Приказ резултата 1-10 од 22
Ad-hoc intercomparison of four different radon exhalation measurement methods
(Radiation Protection Dosimetry, 2018)
It is indicated that the exposure to radon originating from the building materials is not negligible and the radon exhalation measurement should get more attention in the future. The experience with four different methods ...
A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography
(Radiation Protection Dosimetry, 2015)
The article reports from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index ...
Eye Dosimetry in Interventional Radiology and Cardiology: Current Challenges and Practical Considerations
(Radiation Protection Dosimetry, 2014)
Interventional radiology and cardiology are areas with high potential for risk to eye lens. Accurate assessment of eye dose is one of the most important aspects of correlating doses with observed lens opacities among workers ...
Sensitivity and fading of pMOS dosemeters irradiated with X-ray radiation doses from 1 to 100 cGy
(Radiation Protection Dosimetry, 2016)
In this paper, the results of pMOS dosemeters sensitivity to X-ray radiation and 28-d fading at room temperature are presented. Two types of dosemeters were used, which differ in gate oxide layer thickness. The sensitivity ...
Measurement of maximum skin dose in interventional radiology and cardiology and challenges in the set-up of European alert thresholds
(Radiation Protection Dosimetry, 2015)
To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and ...
Patient doses for barium meal examination in Serbia and Montenegro and potentials for dose reduction through changes in equipment settings
(Radiation Protection Dosimetry, 2005)
Patient doses for barium meal examination performed at three general hospitals, in Serbia and Montenegro were measured using a kerma-area product (KAP) meter. The results were analysed in order to obtain dose-related ...
Indoor Radon, Thoron and Their Progeny Concentrations in High Thoron Rural Serbia Environments
(Radiation Protection Dosimetry, 2017)
This article deals with the variation of radon (Rn), thoron (Tn) and their progeny concentrations expressed in terms of equilibrium equivalent concentrations (EERC and EETC), in 40 houses, in four villages of Sokobanja ...
Results from Time Integrated Measurements of Indoor Radon, Thoron and Their Decay Product Concentrations in Schools in the Republic of Macedonia
(Radiation Protection Dosimetry, 2014)
As part of a survey on concentrations of radon, thoron and their decay products in different indoor environments of the Balkan region involving international collaboration, measurements were performed in 43 schools from 5 ...
Field Experience on Indoor Radon, Thoron and Their Progenies with Solid-State Detectors in a Survey of Kosovo and Metohija (Balkan Region)
(Radiation Protection Dosimetry, 2012)
Since 1996/97, indoor radon has been measured in scattered locations around Kosovo. In the most recent campaign, apart from radon, thoron and Rn and Tn progenies have also been measured. The current survey involves 48 ...
Distribution of Uranium and Some Selected Trace Metals in Human Scalp Hair from Balkans
(Radiation Protection Dosimetry, 2012)
The possible consequences of the use of depleted uranium (DU) used in Balkan conflicts in 1995 and 1999 for the people and the environment of this reason need attention. The heavy metal content in human hair may serve as ...