Show simple item record

dc.creatorLazović, Aleksandar
dc.creatorAtanasoski, Vladimir
dc.creatorTadić, Predrag
dc.creatorĐorđević, Natalija
dc.creatorTiosavljević, Maša
dc.creatorIvanović, Marija D.
dc.creatorHadžievski, Ljupčo
dc.creatorRistić, Arsen
dc.creatorVukčević, Vladan
dc.creatorPetrović, Jovana S.
dc.date.accessioned2025-09-03T09:10:03Z
dc.date.available2025-09-03T09:10:03Z
dc.date.issued2025
dc.identifier.issn2052-4463
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/15346
dc.description.abstractNoninvasive electromechanical assessment of cardiovascular function is emerging as a cost-effective method for diagnosis of heart failure and arterial diseases, and for telemedical monitoring of blood pressure and neural disorders. It encompasses simultaneous acquisition of electrocardiographic, phonocardiographic, arterial-pulse, chest-vibration, bioimpedance and other waveforms. The phases and amplitudes of these waveforms are used for construction of disease biomarkers. The procedure includes corrections of biomarker values to daily variation and excursions of heart rate. However, datasets that enable a systematic study of the effects of heart rate on mechanical waveforms are currently not available. Here, we describe SensSmartTech - the first dataset of multiparametric cardiovascular signals systematically measured in a large span of heart rates from 52 to 182 beats per minute, achieved by running on a treadmill. Besides providing the data for biomarker correction, the dataset enables new insights into the cardio-respiratory and electro-mechanical couplings in the cardiovascular system.en
dc.language.isoen
dc.relationinfo:eu-repo/grantAgreement/ScienceFundRS/Ideje/7754338/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200017/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200103/RS//
dc.relation.isbasedonhttps://doi.org/10.13026/fy9p-n277
dc.relation.isreferencedbyhttps://doi.org/10.13026/fy9p-n277
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceScientific Data
dc.titleSynchronous post-exercise electrocardiogram, phonocardiogram, photoplethysmograms and seismocardiogramen
dc.typearticleen
dc.rights.licenseBY-NC-ND
dc.citation.volume12
dc.citation.issue1
dc.citation.spage1452
dc.identifier.doi10.1038/s41597-025-05781-4
dc.citation.rankM21a
dc.description.otherData for the article available at: Lazović, A., Tadić, P., Đorđević, N., Atanasoski, V., Tiosavljevic, M., Ivanovic, M., Hadzievski, L., Ristic, A., Vukcevic, V., & Petrovic, J. (2024). SensSmartTech database of cardiovascular signals synchronously recorded by an electrocardiograph, phonocardiograph, photoplethysmograph and accelerometer (version 1.0.0). PhysioNet. RRID:SCR_007345. [https://doi.org/10.13026/fy9p-n277]en
dc.type.versionpublishedVersion
dc.identifier.fulltexthttp://vinar.vin.bg.ac.rs/bitstream/id/43254/s41597-025-05781-4.pdf


Files in this item

Thumbnail

This item appears in the following Collection(s)

  • Radovi istraživača
    Researchers' publications
  • SensSmart
    [IDEJE] Multi-SENSor SysteM and ARTificial intelligence in service of heart failure diagnosis

Show simple item record