Prikaz osnovnih podataka o dokumentu

dc.creatorĆirić, Aleksandar
dc.creatorRistić, Zoran
dc.creatorGavrilović, Tamara V.
dc.creatorPeriša, Jovana
dc.creatorMedić, Mina
dc.creatorMilićević, Bojana R.
dc.creatorDramićanin, Miroslav
dc.date.accessioned2025-07-07T07:37:10Z
dc.date.available2025-07-07T07:37:10Z
dc.date.issued2025
dc.identifier.issn1863-8880
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/15137
dc.description.abstractAdvancing measurement precision and extending the temperature range are key goals in luminescence thermometry. Traditional single-parameter methods often underperform. Sensor fusion (SF), a statistical tool widely used in fields like autonomous vehicles and medical imaging, is applied to luminescent thermometry by combining multiple sensor probes or treating each temperature-dependent parameter as a separate sensor. This approach consistently enhances precision and extends the temperature range, with fused precision equaling the sum of individual precisions. SF using inverse variance weighting surpasses traditional linear regression models due to its adaptability, achieving maximum performance with any sensor material. It works with both time-resolved and steady-state readouts, using single or multiple excitation sources. Computer simulations and experiments validate this method. For Sm2+, combining lifetime and intensity ratio measurements significantly improves precision across the entire range. Fusion of Mn4+, Ho3+, and Cr3+ lifetimes expands the temperature range to 300–650 K. For Yb3+/Er3+ upconversion green and red emission lifetimes, precision improves across all temperatures. However, Mn5+ shows limited improvement due to the dominance of precision in line-shift measurements, highlighting a limitation of the approach. Overall, SF demonstrates its potential to revolutionize luminescence thermometry by enhancing precision and usability across diverse conditions. © 2025 Wiley-VCH GmbH.en
dc.language.isoen
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200017/RS//
dc.relationinfo:eu-repo/grantAgreement/ScienceFundRS/Prizma2023_TT/7017/RS//
dc.rightsrestrictedAccess
dc.sourceLaser and Photonics Reviews
dc.subjectluminescence intensity ratioen
dc.subjectluminescence lifetimeen
dc.subjectmeasurement uncertaintyen
dc.subjectsensing precisionen
dc.subjectsensor fusionen
dc.titleSensor Fusion in Luminescence Thermometry: A Path to Higher Precision and Broader Applicabilityen
dc.typearticleen
dc.rights.licenseARR
dc.citation.volume19
dc.citation.issue22
dc.citation.spagee00781
dc.identifier.doi10.1002/lpor.202500781
dc.citation.rankM21a
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-105009410991


Dokumenti

Thumbnail

Ovaj dokument se pojavljuje u sledećim kolekcijama

  • Radovi istraživača
    Researchers' publications
  • REMTES
    [PRIZMA] Technology for remote temparature measurements in microfluidic devices

Prikaz osnovnih podataka o dokumentu