Stanković, Srboljub

Link to this page

Authority KeyName Variants
orcid::0000-0001-6952-5604
  • Stanković, Srboljub (145)
  • Stanković, Srboljub J. (9)
Projects
Advanced technologies for monitoring and environmental protection from chemical pollutants and radiation burden Physical and functional effects of radiation interaction with electrotechnical and biological systems
ELICSIR - Enhancement of Sceintific Excellence and Innovation Potential in Electronic Instrumentation for Ionising Radiation Environments Joint research of measurements and effects of ionizing and UV radiation in medicine and environmental protection
Utilization of by-products and recycled waste materials in concrete composites in the scope of sustainable construction development in Serbia: investigation and environmental assessment of possible applications Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200017 (University of Belgrade, Institute of Nuclear Sciences 'Vinča', Belgrade-Vinča)
Characterization, analysis and modeling of physical phenomena in thin layers for application in MOS nanodevices A new approach to foundational problems of quantum mechanics related to applications in quantum technologies and interpretations of signals of various origins
Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200012 (Istitute of Material Testing of Serbia - IMS, Belgrade) Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200026 (University of Belgrade, Institute of Chemistry, Technology and Metallurgy - IChTM)
Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200102 (Univeristy of Niš, Faculty of Electronic Engineering) Synthesis, processing and characterization of nanostructured materials for application in the field of energy, mechanical engineering, environmental protection and biomedicine
Development, optimization and application of energy-harvesting sensors technology 17RPT01 DOSEtrace
Bilateral cooperation project between Turkey and Serbia: “Tailor made self-compacting heavyweight concrete with waste materials” Bilateral cooperation project between Turkey and Serbia: "Tailor made self-compacting heavyweight concrete with waste materials" 2021-2023
Bulgarian National Scientific Fund [KP-06-H37/32] EMPIR [19NET03]
EMPIR [Project 17RPT01 DOSEtrace] European Commission [857558 - ELICSIR, WIDESPREAD-2018-3-TWINNING]
Synthesis, modeling, physicochemical and biological properties of organic compounds and related metal complexes Effects of laser radiation and plasma on novel materials in their synthesis, modification, and analysis
Studies of enzyme interactions with toxic and pharmacologically active molecules Antibiotic resistant bacterial pathogens in Serbia: phenotypic and genotypic characterization
Development of Institutional Capacities, Standards and Procedures for Fighting Organized Crime and Terrorism in Climate of International Integrations Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 451-03-68/2020-14/200135 (University of Belgrade, Faculty of Technology and Metallurgy)
Modulation of intracellular energy balance-controlling signalling pathways in therapy of cancer and neuro-immuno-endocrine disorders Lithium-ion batteries and fuel cells - research and development
Zaštita od zračenja-fundamentalni, teorijski i eksperimentalni fizički aspekti Physics of electromagnetic and radiation compatibility of electrical materials and components

Author's Bibliography

Gamma Irradiation Induced Dyes Degradation: Recent Progress and Future Perspective for Wastewater Treatment

Egerić, Marija; Petrović, Dimitrije; Savić, Marjetka; Devečerski, Aleksandar; Stanković, Srboljub; Vujasin, Radojka; Matović, Ljiljana

(Belgrade : Vinča Institute of Nuclear Sciences - National Institute of thе Republic of Serbia, University of Belgrade, 2024)

TY  - CONF
AU  - Egerić, Marija
AU  - Petrović, Dimitrije
AU  - Savić, Marjetka
AU  - Devečerski, Aleksandar
AU  - Stanković, Srboljub
AU  - Vujasin, Radojka
AU  - Matović, Ljiljana
PY  - 2024
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/13157
PB  - Belgrade : Vinča Institute of Nuclear Sciences - National Institute of thе Republic of Serbia, University of Belgrade
PB  - Belgrade : Serbian Society for Innovative Materials in Extreme Conditions (SIM-EXTREME)
C3  - IMEC2024 - 2nd International Conference on Innovative Materials in Extreme Conditions : Book of abstracts
T1  - Gamma Irradiation Induced Dyes Degradation: Recent Progress and Future Perspective for Wastewater Treatment
SP  - 61
EP  - 61
UR  - https://hdl.handle.net/21.15107/rcub_vinar_13157
ER  - 
@conference{
author = "Egerić, Marija and Petrović, Dimitrije and Savić, Marjetka and Devečerski, Aleksandar and Stanković, Srboljub and Vujasin, Radojka and Matović, Ljiljana",
year = "2024",
publisher = "Belgrade : Vinča Institute of Nuclear Sciences - National Institute of thе Republic of Serbia, University of Belgrade, Belgrade : Serbian Society for Innovative Materials in Extreme Conditions (SIM-EXTREME)",
journal = "IMEC2024 - 2nd International Conference on Innovative Materials in Extreme Conditions : Book of abstracts",
title = "Gamma Irradiation Induced Dyes Degradation: Recent Progress and Future Perspective for Wastewater Treatment",
pages = "61-61",
url = "https://hdl.handle.net/21.15107/rcub_vinar_13157"
}
Egerić, M., Petrović, D., Savić, M., Devečerski, A., Stanković, S., Vujasin, R.,& Matović, L.. (2024). Gamma Irradiation Induced Dyes Degradation: Recent Progress and Future Perspective for Wastewater Treatment. in IMEC2024 - 2nd International Conference on Innovative Materials in Extreme Conditions : Book of abstracts
Belgrade : Vinča Institute of Nuclear Sciences - National Institute of thе Republic of Serbia, University of Belgrade., 61-61.
https://hdl.handle.net/21.15107/rcub_vinar_13157
Egerić M, Petrović D, Savić M, Devečerski A, Stanković S, Vujasin R, Matović L. Gamma Irradiation Induced Dyes Degradation: Recent Progress and Future Perspective for Wastewater Treatment. in IMEC2024 - 2nd International Conference on Innovative Materials in Extreme Conditions : Book of abstracts. 2024;:61-61.
https://hdl.handle.net/21.15107/rcub_vinar_13157 .
Egerić, Marija, Petrović, Dimitrije, Savić, Marjetka, Devečerski, Aleksandar, Stanković, Srboljub, Vujasin, Radojka, Matović, Ljiljana, "Gamma Irradiation Induced Dyes Degradation: Recent Progress and Future Perspective for Wastewater Treatment" in IMEC2024 - 2nd International Conference on Innovative Materials in Extreme Conditions : Book of abstracts (2024):61-61,
https://hdl.handle.net/21.15107/rcub_vinar_13157 .

Gamma irradiation induced degradation of organic pollutants: Recent advances and future perspective

Egerić, Marija; Matović, Ljiljana; Savić, Marjetka; Stanković, Srboljub; Wu, Yi-nan; Li, Fengting; Vujasin, Radojka

(2024)

TY  - JOUR
AU  - Egerić, Marija
AU  - Matović, Ljiljana
AU  - Savić, Marjetka
AU  - Stanković, Srboljub
AU  - Wu, Yi-nan
AU  - Li, Fengting
AU  - Vujasin, Radojka
PY  - 2024
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/13025
AB  - Different organic compounds in aquatic bodies have been recognized as an emerging issue in Environmental Chemistry. The gamma irradiation technique, as one of the advanced oxidation techniques, has been widely investigated in past decades as a technique for the degradation of organic molecules, such as dyes, pesticides, and pharmaceuticals, which show high persistence to degradation. This review gives an overview of what has been achieved so far using gamma irradiation for different organic compound degradations giving an explanation of the mechanisms of degradations as well as the corresponding limitations and drawbacks, and the answer to why this technique has not yet widely come to life. Also, a new approach, recently presented in the literature, regards coupling gamma irradiation with other techniques and materials, as the latest trend. A critical evaluation of the most recent advances achieved by coupling gamma irradiation with other methods and/or materials, as well as describing the reaction mechanisms of coupling, that is, additional destabilization of molecules achieved by coupling, emphasizing the advantages of the newly proposed approach. Finally, it was concluded what are the perspectives and future directions towards its commercialization since this technique can contribute to waste minimization i.e. not waste transfer to other media. Summarizing and generalization the model of radiolytic degradation with and without coupling with other techniques can further guide designing a new modular, mobile method that will satisfy all the needs for its wide commercial application.
T2  - Chemosphere
T1  - Gamma irradiation induced degradation of organic pollutants: Recent advances and future perspective
VL  - 352
SP  - 141437
DO  - 10.1016/j.chemosphere.2024.141437
ER  - 
@article{
author = "Egerić, Marija and Matović, Ljiljana and Savić, Marjetka and Stanković, Srboljub and Wu, Yi-nan and Li, Fengting and Vujasin, Radojka",
year = "2024",
abstract = "Different organic compounds in aquatic bodies have been recognized as an emerging issue in Environmental Chemistry. The gamma irradiation technique, as one of the advanced oxidation techniques, has been widely investigated in past decades as a technique for the degradation of organic molecules, such as dyes, pesticides, and pharmaceuticals, which show high persistence to degradation. This review gives an overview of what has been achieved so far using gamma irradiation for different organic compound degradations giving an explanation of the mechanisms of degradations as well as the corresponding limitations and drawbacks, and the answer to why this technique has not yet widely come to life. Also, a new approach, recently presented in the literature, regards coupling gamma irradiation with other techniques and materials, as the latest trend. A critical evaluation of the most recent advances achieved by coupling gamma irradiation with other methods and/or materials, as well as describing the reaction mechanisms of coupling, that is, additional destabilization of molecules achieved by coupling, emphasizing the advantages of the newly proposed approach. Finally, it was concluded what are the perspectives and future directions towards its commercialization since this technique can contribute to waste minimization i.e. not waste transfer to other media. Summarizing and generalization the model of radiolytic degradation with and without coupling with other techniques can further guide designing a new modular, mobile method that will satisfy all the needs for its wide commercial application.",
journal = "Chemosphere",
title = "Gamma irradiation induced degradation of organic pollutants: Recent advances and future perspective",
volume = "352",
pages = "141437",
doi = "10.1016/j.chemosphere.2024.141437"
}
Egerić, M., Matović, L., Savić, M., Stanković, S., Wu, Y., Li, F.,& Vujasin, R.. (2024). Gamma irradiation induced degradation of organic pollutants: Recent advances and future perspective. in Chemosphere, 352, 141437.
https://doi.org/10.1016/j.chemosphere.2024.141437
Egerić M, Matović L, Savić M, Stanković S, Wu Y, Li F, Vujasin R. Gamma irradiation induced degradation of organic pollutants: Recent advances and future perspective. in Chemosphere. 2024;352:141437.
doi:10.1016/j.chemosphere.2024.141437 .
Egerić, Marija, Matović, Ljiljana, Savić, Marjetka, Stanković, Srboljub, Wu, Yi-nan, Li, Fengting, Vujasin, Radojka, "Gamma irradiation induced degradation of organic pollutants: Recent advances and future perspective" in Chemosphere, 352 (2024):141437,
https://doi.org/10.1016/j.chemosphere.2024.141437 . .

Degradation of Organic Pollutants by Gamma Irradiation: Future Perspective

Matović, Ljiljana; Egerić, Marija; Kolarić, Ljubiša; Petrović, Dimitrije; Savić-Biserčić, Marjetka; Stanković, Srboljub; Vujasin, Radojka

(Leskovac : Faculty of Technology, University of Niš, 2023)

TY  - CONF
AU  - Matović, Ljiljana
AU  - Egerić, Marija
AU  - Kolarić, Ljubiša
AU  - Petrović, Dimitrije
AU  - Savić-Biserčić, Marjetka
AU  - Stanković, Srboljub
AU  - Vujasin, Radojka
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12253
AB  - Worldwide water bodies have been affected by toxic effluents of industries, such as organic compounds, and are continuously deteriorating the environment as industrialization coupled with urbanization has caused the excess release of wastewater. Finding a proper wastewater treatment is of the greatest importance. Gamma irradiation technique, as one of the advanced oxidation techniques, has been widely investigated as a technique for degradation of organic molecules. It has been shown that this method has the potential to be effectively applied for degradation of toxic colorants which show high persistence to degradation. Although the literature abounds with degradation studies of different organic molecules using a wide range of irradiation dozes and doze rates, according to available data, no such irradiation facility exists, mostly due to high doses and expensive equipment needed to be installed. A mechanism of degradation was proposed: generated reactive species non-specifically react with organic compounds leading to their partial or complete degradation. In recent advances, gamma irradiation was coupled with other wastewater treatment technologies to reduce needed doses. Coupling of gamma irradiation was achieved with addition of oxidants which resulted in increased number of reactive species, then coupling with solid matrices, biological treatment, which all lead to additional destabilization of organic molecules. This way, combining different methods of wastewater purification opens new possibilities and may enable the design of a new modular, or even mobile, plant that will satisfy all the needs for its wide commercial application. As a result, a sustainable development goal can be more easily reachable, i.e., sustainable water resources management in future industrial zones and smart cities may be possible without generation of waste transfer into another media.
PB  - Leskovac : Faculty of Technology, University of Niš
C3  - 15th International symposium „Novel technologies and sustainable development" : Book of Abstracts
T1  - Degradation of Organic Pollutants by Gamma Irradiation: Future Perspective
SP  - 116
EP  - 116
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12253
ER  - 
@conference{
author = "Matović, Ljiljana and Egerić, Marija and Kolarić, Ljubiša and Petrović, Dimitrije and Savić-Biserčić, Marjetka and Stanković, Srboljub and Vujasin, Radojka",
year = "2023",
abstract = "Worldwide water bodies have been affected by toxic effluents of industries, such as organic compounds, and are continuously deteriorating the environment as industrialization coupled with urbanization has caused the excess release of wastewater. Finding a proper wastewater treatment is of the greatest importance. Gamma irradiation technique, as one of the advanced oxidation techniques, has been widely investigated as a technique for degradation of organic molecules. It has been shown that this method has the potential to be effectively applied for degradation of toxic colorants which show high persistence to degradation. Although the literature abounds with degradation studies of different organic molecules using a wide range of irradiation dozes and doze rates, according to available data, no such irradiation facility exists, mostly due to high doses and expensive equipment needed to be installed. A mechanism of degradation was proposed: generated reactive species non-specifically react with organic compounds leading to their partial or complete degradation. In recent advances, gamma irradiation was coupled with other wastewater treatment technologies to reduce needed doses. Coupling of gamma irradiation was achieved with addition of oxidants which resulted in increased number of reactive species, then coupling with solid matrices, biological treatment, which all lead to additional destabilization of organic molecules. This way, combining different methods of wastewater purification opens new possibilities and may enable the design of a new modular, or even mobile, plant that will satisfy all the needs for its wide commercial application. As a result, a sustainable development goal can be more easily reachable, i.e., sustainable water resources management in future industrial zones and smart cities may be possible without generation of waste transfer into another media.",
publisher = "Leskovac : Faculty of Technology, University of Niš",
journal = "15th International symposium „Novel technologies and sustainable development" : Book of Abstracts",
title = "Degradation of Organic Pollutants by Gamma Irradiation: Future Perspective",
pages = "116-116",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12253"
}
Matović, L., Egerić, M., Kolarić, L., Petrović, D., Savić-Biserčić, M., Stanković, S.,& Vujasin, R.. (2023). Degradation of Organic Pollutants by Gamma Irradiation: Future Perspective. in 15th International symposium „Novel technologies and sustainable development" : Book of Abstracts
Leskovac : Faculty of Technology, University of Niš., 116-116.
https://hdl.handle.net/21.15107/rcub_vinar_12253
Matović L, Egerić M, Kolarić L, Petrović D, Savić-Biserčić M, Stanković S, Vujasin R. Degradation of Organic Pollutants by Gamma Irradiation: Future Perspective. in 15th International symposium „Novel technologies and sustainable development" : Book of Abstracts. 2023;:116-116.
https://hdl.handle.net/21.15107/rcub_vinar_12253 .
Matović, Ljiljana, Egerić, Marija, Kolarić, Ljubiša, Petrović, Dimitrije, Savić-Biserčić, Marjetka, Stanković, Srboljub, Vujasin, Radojka, "Degradation of Organic Pollutants by Gamma Irradiation: Future Perspective" in 15th International symposium „Novel technologies and sustainable development" : Book of Abstracts (2023):116-116,
https://hdl.handle.net/21.15107/rcub_vinar_12253 .

Effects in Commercial p-Channel Power VDMOS Transistors Initiated by Negative Bias Temperature Stress and Irradiation

Veljković, Sandra; Mitrović, Nikola; Đorić-Veljković, Snežana; Davidović, Vojkan; Živanović, E.; Stanković, Srboljub; Anđelković, M.; Ristić, G.; Paskleva, A.; Spassov, D.; Danković, Danijel; Manić, I.

(IEEE : Institute of Electrical and Electronics Engineers, 2023)

TY  - CONF
AU  - Veljković, Sandra
AU  - Mitrović, Nikola
AU  - Đorić-Veljković, Snežana
AU  - Davidović, Vojkan
AU  - Živanović, E.
AU  - Stanković, Srboljub
AU  - Anđelković, M.
AU  - Ristić, G.
AU  - Paskleva, A.
AU  - Spassov, D.
AU  - Danković, Danijel
AU  - Manić, I.
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12120
AB  - This paper investigates the impact of negative bias temperature stress on irradiated commercial p-channel power VDMOS transistors, particularly focusing on gate oxide charge and interface trap alterations and their contribution to threshold voltage shifts. The study addresses the critical issue of transistor reliability, as threshold voltage shifts can significantly affect device performance, especially in elevated temperature and negative gate oxide field conditions. Additionally, the research explores the effects of irradiation on VDMOS power transistors, emphasizing the importance of understanding the associated electrical parameter changes. The paper presents a comprehensive analysis of static and pulsed NBT stressing, with a specific focus on novel stress signals encountered in practical applications. The experimental procedure involves irradiation and NBT stress, and the results reveal insights into the contributions of gate oxide charge and interface traps to threshold voltage shifts. The findings shed light on the reliability of electronic equipment incorporating p-channel power VDMOS transistors under various stress conditions, offering valuable insights for device design and operation.
PB  - IEEE : Institute of Electrical and Electronics Engineers
C3  - MIEL : 33rd International Conference on Microelectronics : Proceedings book
T1  - Effects in Commercial p-Channel Power VDMOS Transistors Initiated by Negative Bias Temperature Stress and Irradiation
SP  - 277
EP  - 280
DO  - 10.1109/MIEL58498.2023.10315932
ER  - 
@conference{
author = "Veljković, Sandra and Mitrović, Nikola and Đorić-Veljković, Snežana and Davidović, Vojkan and Živanović, E. and Stanković, Srboljub and Anđelković, M. and Ristić, G. and Paskleva, A. and Spassov, D. and Danković, Danijel and Manić, I.",
year = "2023",
abstract = "This paper investigates the impact of negative bias temperature stress on irradiated commercial p-channel power VDMOS transistors, particularly focusing on gate oxide charge and interface trap alterations and their contribution to threshold voltage shifts. The study addresses the critical issue of transistor reliability, as threshold voltage shifts can significantly affect device performance, especially in elevated temperature and negative gate oxide field conditions. Additionally, the research explores the effects of irradiation on VDMOS power transistors, emphasizing the importance of understanding the associated electrical parameter changes. The paper presents a comprehensive analysis of static and pulsed NBT stressing, with a specific focus on novel stress signals encountered in practical applications. The experimental procedure involves irradiation and NBT stress, and the results reveal insights into the contributions of gate oxide charge and interface traps to threshold voltage shifts. The findings shed light on the reliability of electronic equipment incorporating p-channel power VDMOS transistors under various stress conditions, offering valuable insights for device design and operation.",
publisher = "IEEE : Institute of Electrical and Electronics Engineers",
journal = "MIEL : 33rd International Conference on Microelectronics : Proceedings book",
title = "Effects in Commercial p-Channel Power VDMOS Transistors Initiated by Negative Bias Temperature Stress and Irradiation",
pages = "277-280",
doi = "10.1109/MIEL58498.2023.10315932"
}
Veljković, S., Mitrović, N., Đorić-Veljković, S., Davidović, V., Živanović, E., Stanković, S., Anđelković, M., Ristić, G., Paskleva, A., Spassov, D., Danković, D.,& Manić, I.. (2023). Effects in Commercial p-Channel Power VDMOS Transistors Initiated by Negative Bias Temperature Stress and Irradiation. in MIEL : 33rd International Conference on Microelectronics : Proceedings book
IEEE : Institute of Electrical and Electronics Engineers., 277-280.
https://doi.org/10.1109/MIEL58498.2023.10315932
Veljković S, Mitrović N, Đorić-Veljković S, Davidović V, Živanović E, Stanković S, Anđelković M, Ristić G, Paskleva A, Spassov D, Danković D, Manić I. Effects in Commercial p-Channel Power VDMOS Transistors Initiated by Negative Bias Temperature Stress and Irradiation. in MIEL : 33rd International Conference on Microelectronics : Proceedings book. 2023;:277-280.
doi:10.1109/MIEL58498.2023.10315932 .
Veljković, Sandra, Mitrović, Nikola, Đorić-Veljković, Snežana, Davidović, Vojkan, Živanović, E., Stanković, Srboljub, Anđelković, M., Ristić, G., Paskleva, A., Spassov, D., Danković, Danijel, Manić, I., "Effects in Commercial p-Channel Power VDMOS Transistors Initiated by Negative Bias Temperature Stress and Irradiation" in MIEL : 33rd International Conference on Microelectronics : Proceedings book (2023):277-280,
https://doi.org/10.1109/MIEL58498.2023.10315932 . .

The Effect of Honey on Malondialdehyde Level in Plasma Exposed to a Therapeutic Dose of Radiation

Stanić, Vojislav; Gavrilović, Ljubica; Stojiljković, Vesna; Karakašević, Aleksandar; Pantelić, Marija; Gerić, Tamara; Stanković, Srboljub

(Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča", 2023)

TY  - CONF
AU  - Stanić, Vojislav
AU  - Gavrilović, Ljubica
AU  - Stojiljković, Vesna
AU  - Karakašević, Aleksandar
AU  - Pantelić, Marija
AU  - Gerić, Tamara
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12189
AB  - Malondialdehyde (MDA) is the end product of lipid peroxidation and biomarker of free radicals. The aim of this study is to investigate the effect of honey on concentrations of MDA in plasma exposed to a therapeutic dose of radiation. In this experiment animals were divided into two groups: in CONTROL group the animals were given distilled water orally for 28 days, and HONEY group consisted of animals given 1,5 ml/kg honey orally for 28 days. Blood samples of both groups were collected from a rat's tail. All blood samples were exposed to radiation of 2 Gy. Malondialdehyde concentration in plasma was determined using spectrophotometric method. Honey treatment in the blood plasma exposed to a therapeutic dose of 2 Gy significantly decreased MDA level by 30 % compared with control group. The present results indicated that honey had an effect on the levels of MDA in plasma exposed to radiation.
AB  - Malondialdehid (MDA) je krajnji proizvod peroksidacije lipida i biomarker slobodnih radikala. Cilj ovog istraživanja je bio da se ispita uticaj meda na koncentraciju MDA u krvnoj plazmi izloženoj terapijskoj dozi zračenja. U ovom eksperimentu životinje su podeljene u dve grupe: u kontrolnoj grupi životinje su dobijale destilovanu vodu oralno tokom 28 dana, a drugu grupu činile su životinje koje su tokom 28 dana dobijale oralno 1.5 ml/kg meda. Uzorci krvi obe grupe su sakupljeni iz repa pacova. Svi uzorci krvi bili su izloženi zračenju od 2 Gy. Koncentracija MDA u plazmi određena je spektrofotometrijskom metodom. Tretman medom u krvnoj plazmi izložen terapijskoj dozi od 2 Gy značajno je smanjio nivo MDA (30 %) u poređenju sa kontrolnom grupom.
PB  - Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča"
PB  - Društvo za zaštitu od zračenja Srbije i Crne Gore
C3  - 32. simpozijum DZZSCG : zbornik radova
T1  - The Effect of Honey on Malondialdehyde Level in Plasma Exposed to a Therapeutic Dose of Radiation
T1  - Delovanje meda na nivo malondialdehida u plazmi izloženoj terapijskoj dozi zračenja
SP  - 417
EP  - 423
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12189
ER  - 
@conference{
author = "Stanić, Vojislav and Gavrilović, Ljubica and Stojiljković, Vesna and Karakašević, Aleksandar and Pantelić, Marija and Gerić, Tamara and Stanković, Srboljub",
year = "2023",
abstract = "Malondialdehyde (MDA) is the end product of lipid peroxidation and biomarker of free radicals. The aim of this study is to investigate the effect of honey on concentrations of MDA in plasma exposed to a therapeutic dose of radiation. In this experiment animals were divided into two groups: in CONTROL group the animals were given distilled water orally for 28 days, and HONEY group consisted of animals given 1,5 ml/kg honey orally for 28 days. Blood samples of both groups were collected from a rat's tail. All blood samples were exposed to radiation of 2 Gy. Malondialdehyde concentration in plasma was determined using spectrophotometric method. Honey treatment in the blood plasma exposed to a therapeutic dose of 2 Gy significantly decreased MDA level by 30 % compared with control group. The present results indicated that honey had an effect on the levels of MDA in plasma exposed to radiation., Malondialdehid (MDA) je krajnji proizvod peroksidacije lipida i biomarker slobodnih radikala. Cilj ovog istraživanja je bio da se ispita uticaj meda na koncentraciju MDA u krvnoj plazmi izloženoj terapijskoj dozi zračenja. U ovom eksperimentu životinje su podeljene u dve grupe: u kontrolnoj grupi životinje su dobijale destilovanu vodu oralno tokom 28 dana, a drugu grupu činile su životinje koje su tokom 28 dana dobijale oralno 1.5 ml/kg meda. Uzorci krvi obe grupe su sakupljeni iz repa pacova. Svi uzorci krvi bili su izloženi zračenju od 2 Gy. Koncentracija MDA u plazmi određena je spektrofotometrijskom metodom. Tretman medom u krvnoj plazmi izložen terapijskoj dozi od 2 Gy značajno je smanjio nivo MDA (30 %) u poređenju sa kontrolnom grupom.",
publisher = "Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča", Društvo za zaštitu od zračenja Srbije i Crne Gore",
journal = "32. simpozijum DZZSCG : zbornik radova",
title = "The Effect of Honey on Malondialdehyde Level in Plasma Exposed to a Therapeutic Dose of Radiation, Delovanje meda na nivo malondialdehida u plazmi izloženoj terapijskoj dozi zračenja",
pages = "417-423",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12189"
}
Stanić, V., Gavrilović, L., Stojiljković, V., Karakašević, A., Pantelić, M., Gerić, T.,& Stanković, S.. (2023). The Effect of Honey on Malondialdehyde Level in Plasma Exposed to a Therapeutic Dose of Radiation. in 32. simpozijum DZZSCG : zbornik radova
Beograd : Univerzitet u Beogradu, Institut za nuklearne nauke "Vinča"., 417-423.
https://hdl.handle.net/21.15107/rcub_vinar_12189
Stanić V, Gavrilović L, Stojiljković V, Karakašević A, Pantelić M, Gerić T, Stanković S. The Effect of Honey on Malondialdehyde Level in Plasma Exposed to a Therapeutic Dose of Radiation. in 32. simpozijum DZZSCG : zbornik radova. 2023;:417-423.
https://hdl.handle.net/21.15107/rcub_vinar_12189 .
Stanić, Vojislav, Gavrilović, Ljubica, Stojiljković, Vesna, Karakašević, Aleksandar, Pantelić, Marija, Gerić, Tamara, Stanković, Srboljub, "The Effect of Honey on Malondialdehyde Level in Plasma Exposed to a Therapeutic Dose of Radiation" in 32. simpozijum DZZSCG : zbornik radova (2023):417-423,
https://hdl.handle.net/21.15107/rcub_vinar_12189 .

Evaluation of a new procedure for stability checks of well-type brachytherapy chambers

Komatina, Ivana; Živanović, Miloš; Kržanović, Nikola; Đaletić, Miloš; Stanković, Srboljub

(Niš : Sievert Association, 2023)

TY  - CONF
AU  - Komatina, Ivana
AU  - Živanović, Miloš
AU  - Kržanović, Nikola
AU  - Đaletić, Miloš
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11911
AB  - Well-type ionization chambers are routinely used for measurements in brachytherapy departments. Since there is no calibration service for brachytherapy ionization chambers available in Serbia, Secondary Standards Dosimetry Laboratory (SSDL) in Vinca Institute of Nuclear Sciences started establishing this service, using a reference well-type chamber Standard Imaging HDR-1000 plus with a PTW Unidos Webline electrometer. The outer wall of the chamber is made of 20 mm thick aluminum, which reduces the influence of the scattered radiation. For each source there is a unique source holder for placement in a reproducible geometry inside the well of the chamber. The ionization chamber stability has to be checked periodically to ensure reliable measurements. IAEA Technical Report Series (TRS) 1274 [IAEA TRS 1247, IAEA 2002] gives guidelines on standardized procedures at SSDLs and hospitals, including the procedure for stability checks of welltype chambers. According to this procedure, 137Cs or 60Co check sources are inserted in the chamber well, using spacers or holders to achieve reproducible geometry. Measurements during stability checks should remain within ±0.5%. In this research, a different procedure for stability checks was tested. A teletherapy 60Co irradiator was used for external irradiation of the well-type chamber. All measurements were corrected for air density (ambient temperature and pressure). Measurements were done in a minimum scatter environment, which was achieved by positioning the ionization chamber 1 m from the irradiator, with the field size of 20x20cm. Correction for 60Co half-life was applied to all measurements. First, the influence of the source holders was tested, and no significant differences were found (0.16% maximum difference when holder is placed in chamber, compared to no holder present). All the subsequent measurements were performed without source holders. During the second test, 4 stability checks were performed during a period of 4 days without moving the chamber or irradiator. The deviations were within the interval -0.39% – +0.25% compared to the first stability check measurement. During the third test, 7 stability checks were performed during a period of 7 days, and complete setup was repeated during each check (chamber positioning, bench positioning, collimator setup etc.). The purpose of the second test was to check the repeatability of positioning, because the positioning can artificially increase deviations between subsequent measurements, making the chamber stability appear worse. All the results were within the interval -0.17% – +0.27%. The results show that this procedure can be adequate for the stability checks of well-type chambers, because the repeatability due to the changes in measurement procedures setup is better than the 0.5%. Differences between second and third test could be caused by insufficient thermalization of the chamber during the second test.
PB  - Niš : Sievert Association
C3  - RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts
T1  - Evaluation of a new procedure for stability checks of well-type brachytherapy chambers
SP  - 120
EP  - 120
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11911
ER  - 
@conference{
author = "Komatina, Ivana and Živanović, Miloš and Kržanović, Nikola and Đaletić, Miloš and Stanković, Srboljub",
year = "2023",
abstract = "Well-type ionization chambers are routinely used for measurements in brachytherapy departments. Since there is no calibration service for brachytherapy ionization chambers available in Serbia, Secondary Standards Dosimetry Laboratory (SSDL) in Vinca Institute of Nuclear Sciences started establishing this service, using a reference well-type chamber Standard Imaging HDR-1000 plus with a PTW Unidos Webline electrometer. The outer wall of the chamber is made of 20 mm thick aluminum, which reduces the influence of the scattered radiation. For each source there is a unique source holder for placement in a reproducible geometry inside the well of the chamber. The ionization chamber stability has to be checked periodically to ensure reliable measurements. IAEA Technical Report Series (TRS) 1274 [IAEA TRS 1247, IAEA 2002] gives guidelines on standardized procedures at SSDLs and hospitals, including the procedure for stability checks of welltype chambers. According to this procedure, 137Cs or 60Co check sources are inserted in the chamber well, using spacers or holders to achieve reproducible geometry. Measurements during stability checks should remain within ±0.5%. In this research, a different procedure for stability checks was tested. A teletherapy 60Co irradiator was used for external irradiation of the well-type chamber. All measurements were corrected for air density (ambient temperature and pressure). Measurements were done in a minimum scatter environment, which was achieved by positioning the ionization chamber 1 m from the irradiator, with the field size of 20x20cm. Correction for 60Co half-life was applied to all measurements. First, the influence of the source holders was tested, and no significant differences were found (0.16% maximum difference when holder is placed in chamber, compared to no holder present). All the subsequent measurements were performed without source holders. During the second test, 4 stability checks were performed during a period of 4 days without moving the chamber or irradiator. The deviations were within the interval -0.39% – +0.25% compared to the first stability check measurement. During the third test, 7 stability checks were performed during a period of 7 days, and complete setup was repeated during each check (chamber positioning, bench positioning, collimator setup etc.). The purpose of the second test was to check the repeatability of positioning, because the positioning can artificially increase deviations between subsequent measurements, making the chamber stability appear worse. All the results were within the interval -0.17% – +0.27%. The results show that this procedure can be adequate for the stability checks of well-type chambers, because the repeatability due to the changes in measurement procedures setup is better than the 0.5%. Differences between second and third test could be caused by insufficient thermalization of the chamber during the second test.",
publisher = "Niš : Sievert Association",
journal = "RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts",
title = "Evaluation of a new procedure for stability checks of well-type brachytherapy chambers",
pages = "120-120",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11911"
}
Komatina, I., Živanović, M., Kržanović, N., Đaletić, M.,& Stanković, S.. (2023). Evaluation of a new procedure for stability checks of well-type brachytherapy chambers. in RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts
Niš : Sievert Association., 120-120.
https://hdl.handle.net/21.15107/rcub_vinar_11911
Komatina I, Živanović M, Kržanović N, Đaletić M, Stanković S. Evaluation of a new procedure for stability checks of well-type brachytherapy chambers. in RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts. 2023;:120-120.
https://hdl.handle.net/21.15107/rcub_vinar_11911 .
Komatina, Ivana, Živanović, Miloš, Kržanović, Nikola, Đaletić, Miloš, Stanković, Srboljub, "Evaluation of a new procedure for stability checks of well-type brachytherapy chambers" in RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts (2023):120-120,
https://hdl.handle.net/21.15107/rcub_vinar_11911 .

Uspostavljanje etalonskog polja za male vrednosti jačine doznog ekvivalenta

Živanović, Miloš; Komatina, Ivana; Kržanović, Nikola; Đaletić, Miloš; Stanković, Srboljub

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2023)

TY  - CONF
AU  - Živanović, Miloš
AU  - Komatina, Ivana
AU  - Kržanović, Nikola
AU  - Đaletić, Miloš
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11924
AB  - U ovom radu je prikazano korišćenje scintilacionog detektora za etaloniranje polja izvora gama zračenja male aktivnosti, za primenu u etaloniranju fotonskih dozimetara. Sledivost je obezbeđena tako što je scintilacioni detektor etaloniran koristeći jonizacionu komoru i izvor veće aktivnosti za nekoliko vrednosti jačine kerme, što je omogućilo da se odredi i njegova linearnost. Identifikovani su najvažniji doprinosi mernoj nesigurnosti etaloniranja polja, a kombinovana merna nesigurnost iznosi 4,6% (k = 2). Mala merna nesigurnost je od posebnog značaja za overavanje dozimetara
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 32. simpozijum DZZSCG : zbornik radova
T1  - Uspostavljanje etalonskog polja za male vrednosti jačine doznog ekvivalenta
SP  - 362
EP  - 367
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11924
ER  - 
@conference{
author = "Živanović, Miloš and Komatina, Ivana and Kržanović, Nikola and Đaletić, Miloš and Stanković, Srboljub",
year = "2023",
abstract = "U ovom radu je prikazano korišćenje scintilacionog detektora za etaloniranje polja izvora gama zračenja male aktivnosti, za primenu u etaloniranju fotonskih dozimetara. Sledivost je obezbeđena tako što je scintilacioni detektor etaloniran koristeći jonizacionu komoru i izvor veće aktivnosti za nekoliko vrednosti jačine kerme, što je omogućilo da se odredi i njegova linearnost. Identifikovani su najvažniji doprinosi mernoj nesigurnosti etaloniranja polja, a kombinovana merna nesigurnost iznosi 4,6% (k = 2). Mala merna nesigurnost je od posebnog značaja za overavanje dozimetara",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "32. simpozijum DZZSCG : zbornik radova",
title = "Uspostavljanje etalonskog polja za male vrednosti jačine doznog ekvivalenta",
pages = "362-367",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11924"
}
Živanović, M., Komatina, I., Kržanović, N., Đaletić, M.,& Stanković, S.. (2023). Uspostavljanje etalonskog polja za male vrednosti jačine doznog ekvivalenta. in 32. simpozijum DZZSCG : zbornik radova
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 362-367.
https://hdl.handle.net/21.15107/rcub_vinar_11924
Živanović M, Komatina I, Kržanović N, Đaletić M, Stanković S. Uspostavljanje etalonskog polja za male vrednosti jačine doznog ekvivalenta. in 32. simpozijum DZZSCG : zbornik radova. 2023;:362-367.
https://hdl.handle.net/21.15107/rcub_vinar_11924 .
Živanović, Miloš, Komatina, Ivana, Kržanović, Nikola, Đaletić, Miloš, Stanković, Srboljub, "Uspostavljanje etalonskog polja za male vrednosti jačine doznog ekvivalenta" in 32. simpozijum DZZSCG : zbornik radova (2023):362-367,
https://hdl.handle.net/21.15107/rcub_vinar_11924 .

Provera radioterapijskih ustanova Srbije od 2019. do 2022. godine poštanskom dozimetrijom u veličini apsorbovana doza u vodi

Kržanović, Nikola; Živanović, Miloš; Đaletić, Miloš; Komatina, Ivana; Kojić, Andrea; Stanković, Srboljub

(Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе, 2023)

TY  - CONF
AU  - Kržanović, Nikola
AU  - Živanović, Miloš
AU  - Đaletić, Miloš
AU  - Komatina, Ivana
AU  - Kojić, Andrea
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11926
AB  - U svrhu osiguranja kvaliteta sprovođenja radioterapijskih procedura, radioterapijski centri širom sveta učestvuju u programu poštanske dozimetrije koju organizuje i sprovodi Međunarodna agencija za atomsku energiju putem globalne mreže Sekundarnih Standardnih Dozimetrijskih Laboratorija. Kontrola kvaliteta podrazumeva ozračivanje pasivnih detektora zračenja (prethodno termoluminiscentnih, danas radiofotoluminiscentnih dozimetara) na poznatu vrednost apsorbovane doze u vodi u visokoenergetskim poljima x-zračenja linearnih akceleratora koji su upotrebi u redovnoj teleterapijskoj praksi. Laboratorija za zaštitu od zračenja i zaštitu životne sredine je u periodu od 2019. do 2022. godine distribuirala pasivne dozimetre radioterapijskim centrima u Srbiji.
AB  - In order to perform quality assurance of radiotherapy procedures, radiotherapy centers participate in a worldwide programme of postal dosimetry external audits, organized by the International Atomic Energy Agency via the global Secondary Standard Dosimetry Laboratory network. Quality control is performed by delivering a known absorbed dose to water value to the passive ionizing radiation detectors (previously thermoluminiscent, recently radiophotoluminiscent dosimeters) in the high-energy x-radiation fields of linear accelerators which are in regular hospital use in teletherapy. Laboratory for radiation and environmental protection has distributed the passive dosimeters to the radiotherapy centers in Serbia in the period from 2019. to 2022.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 32. simpozijum DZZSCG : zbornik radova
T1  - Provera radioterapijskih ustanova Srbije od 2019. do 2022. godine poštanskom dozimetrijom u veličini apsorbovana doza u vodi
T1  - Postal dosimetry audit of radiotherapy centers in Serbia for the period from 2019. to 2022. in terms of absorbed dose to water
SP  - 376
EP  - 381
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11926
ER  - 
@conference{
author = "Kržanović, Nikola and Živanović, Miloš and Đaletić, Miloš and Komatina, Ivana and Kojić, Andrea and Stanković, Srboljub",
year = "2023",
abstract = "U svrhu osiguranja kvaliteta sprovođenja radioterapijskih procedura, radioterapijski centri širom sveta učestvuju u programu poštanske dozimetrije koju organizuje i sprovodi Međunarodna agencija za atomsku energiju putem globalne mreže Sekundarnih Standardnih Dozimetrijskih Laboratorija. Kontrola kvaliteta podrazumeva ozračivanje pasivnih detektora zračenja (prethodno termoluminiscentnih, danas radiofotoluminiscentnih dozimetara) na poznatu vrednost apsorbovane doze u vodi u visokoenergetskim poljima x-zračenja linearnih akceleratora koji su upotrebi u redovnoj teleterapijskoj praksi. Laboratorija za zaštitu od zračenja i zaštitu životne sredine je u periodu od 2019. do 2022. godine distribuirala pasivne dozimetre radioterapijskim centrima u Srbiji., In order to perform quality assurance of radiotherapy procedures, radiotherapy centers participate in a worldwide programme of postal dosimetry external audits, organized by the International Atomic Energy Agency via the global Secondary Standard Dosimetry Laboratory network. Quality control is performed by delivering a known absorbed dose to water value to the passive ionizing radiation detectors (previously thermoluminiscent, recently radiophotoluminiscent dosimeters) in the high-energy x-radiation fields of linear accelerators which are in regular hospital use in teletherapy. Laboratory for radiation and environmental protection has distributed the passive dosimeters to the radiotherapy centers in Serbia in the period from 2019. to 2022.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "32. simpozijum DZZSCG : zbornik radova",
title = "Provera radioterapijskih ustanova Srbije od 2019. do 2022. godine poštanskom dozimetrijom u veličini apsorbovana doza u vodi, Postal dosimetry audit of radiotherapy centers in Serbia for the period from 2019. to 2022. in terms of absorbed dose to water",
pages = "376-381",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11926"
}
Kržanović, N., Živanović, M., Đaletić, M., Komatina, I., Kojić, A.,& Stanković, S.. (2023). Provera radioterapijskih ustanova Srbije od 2019. do 2022. godine poštanskom dozimetrijom u veličini apsorbovana doza u vodi. in 32. simpozijum DZZSCG : zbornik radova
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 376-381.
https://hdl.handle.net/21.15107/rcub_vinar_11926
Kržanović N, Živanović M, Đaletić M, Komatina I, Kojić A, Stanković S. Provera radioterapijskih ustanova Srbije od 2019. do 2022. godine poštanskom dozimetrijom u veličini apsorbovana doza u vodi. in 32. simpozijum DZZSCG : zbornik radova. 2023;:376-381.
https://hdl.handle.net/21.15107/rcub_vinar_11926 .
Kržanović, Nikola, Živanović, Miloš, Đaletić, Miloš, Komatina, Ivana, Kojić, Andrea, Stanković, Srboljub, "Provera radioterapijskih ustanova Srbije od 2019. do 2022. godine poštanskom dozimetrijom u veličini apsorbovana doza u vodi" in 32. simpozijum DZZSCG : zbornik radova (2023):376-381,
https://hdl.handle.net/21.15107/rcub_vinar_11926 .

Gamma and X radiation attenuation characteristics for ultrahigh properties of concrete, concrete with barite and concrete with magnetite and steel

Janković, Ksenija; Stanković, Srboljub; Terzić, Anja; Bojović, Dragan; Stojanović, Marko

(Niš : RAD Centre, 2023)

TY  - CONF
AU  - Janković, Ksenija
AU  - Stanković, Srboljub
AU  - Terzić, Anja
AU  - Bojović, Dragan
AU  - Stojanović, Marko
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12140
AB  - During the implementation of construction barrier design procedures for protection against gamma and X
radiation, the inevitable question arises of choosing building materials with suitable mechanical and radiation
characteristics for protective barriers. Based on engineering practice, it is necessary to compare different
types of concrete used for the construction of buildings in which there are sources of gamma and X radiation,
as in cases where radiation sources appear in medical institutions with linear accelerators, cyclotron
installations for the acceleration of nuclear particles, in the environment of nuclear reactors, in radioactive
waste warehouses or in radiation sterilization units. In the analysis of costs and benefits, several criteria are
used to evaluate the characteristics of concrete, so that, in addition to the mechanical ones, the radiation
characteristics of the building material are also taken into account. One of the most important characteristics
of radiation shielding concrete is its overall mass attenuation coefficient. In this paper, the XCOM computer
code was used to calculate the total mass attenuation coefficients in the energy range from 0.01 MeV to 100
MeV for three types of concrete: ultrahight properties concrete (UHPC), concrete with barite and concrete
with magnetite and steel. Based on the comparison of the calculation results, it was concluded that concrete
with magnetite and steel has a greater protective power than the other two types of concrete for gamma and X
radiation energy lower than 30 keV. Another important conclusion is that concrete with barite has a higher
protective power than the other two types of concrete in the photon energy range from 30 keV to 300 keV,
and for photon energy greater than 6 MeV. A detailed analysis of the calculation results revealed that in the
energy range from 400 keV to 6 MeV the values for the total mass attenuation coefficients are approximately
the same for three different types of concrete.
PB  - Niš : RAD Centre
C3  - RAD 2023 : 11th International Conference on Radiation Natural Sciences, Medicine, Engineering, Technology and Ecology : Book of Abstracts
T1  - Gamma and X radiation attenuation characteristics for ultrahigh properties of concrete, concrete with barite and concrete with magnetite and steel
SP  - 239
EP  - 239
DO  - 10.21175/rad.abstr.book.2023.36.19
ER  - 
@conference{
author = "Janković, Ksenija and Stanković, Srboljub and Terzić, Anja and Bojović, Dragan and Stojanović, Marko",
year = "2023",
abstract = "During the implementation of construction barrier design procedures for protection against gamma and X
radiation, the inevitable question arises of choosing building materials with suitable mechanical and radiation
characteristics for protective barriers. Based on engineering practice, it is necessary to compare different
types of concrete used for the construction of buildings in which there are sources of gamma and X radiation,
as in cases where radiation sources appear in medical institutions with linear accelerators, cyclotron
installations for the acceleration of nuclear particles, in the environment of nuclear reactors, in radioactive
waste warehouses or in radiation sterilization units. In the analysis of costs and benefits, several criteria are
used to evaluate the characteristics of concrete, so that, in addition to the mechanical ones, the radiation
characteristics of the building material are also taken into account. One of the most important characteristics
of radiation shielding concrete is its overall mass attenuation coefficient. In this paper, the XCOM computer
code was used to calculate the total mass attenuation coefficients in the energy range from 0.01 MeV to 100
MeV for three types of concrete: ultrahight properties concrete (UHPC), concrete with barite and concrete
with magnetite and steel. Based on the comparison of the calculation results, it was concluded that concrete
with magnetite and steel has a greater protective power than the other two types of concrete for gamma and X
radiation energy lower than 30 keV. Another important conclusion is that concrete with barite has a higher
protective power than the other two types of concrete in the photon energy range from 30 keV to 300 keV,
and for photon energy greater than 6 MeV. A detailed analysis of the calculation results revealed that in the
energy range from 400 keV to 6 MeV the values for the total mass attenuation coefficients are approximately
the same for three different types of concrete.",
publisher = "Niš : RAD Centre",
journal = "RAD 2023 : 11th International Conference on Radiation Natural Sciences, Medicine, Engineering, Technology and Ecology : Book of Abstracts",
title = "Gamma and X radiation attenuation characteristics for ultrahigh properties of concrete, concrete with barite and concrete with magnetite and steel",
pages = "239-239",
doi = "10.21175/rad.abstr.book.2023.36.19"
}
Janković, K., Stanković, S., Terzić, A., Bojović, D.,& Stojanović, M.. (2023). Gamma and X radiation attenuation characteristics for ultrahigh properties of concrete, concrete with barite and concrete with magnetite and steel. in RAD 2023 : 11th International Conference on Radiation Natural Sciences, Medicine, Engineering, Technology and Ecology : Book of Abstracts
Niš : RAD Centre., 239-239.
https://doi.org/10.21175/rad.abstr.book.2023.36.19
Janković K, Stanković S, Terzić A, Bojović D, Stojanović M. Gamma and X radiation attenuation characteristics for ultrahigh properties of concrete, concrete with barite and concrete with magnetite and steel. in RAD 2023 : 11th International Conference on Radiation Natural Sciences, Medicine, Engineering, Technology and Ecology : Book of Abstracts. 2023;:239-239.
doi:10.21175/rad.abstr.book.2023.36.19 .
Janković, Ksenija, Stanković, Srboljub, Terzić, Anja, Bojović, Dragan, Stojanović, Marko, "Gamma and X radiation attenuation characteristics for ultrahigh properties of concrete, concrete with barite and concrete with magnetite and steel" in RAD 2023 : 11th International Conference on Radiation Natural Sciences, Medicine, Engineering, Technology and Ecology : Book of Abstracts (2023):239-239,
https://doi.org/10.21175/rad.abstr.book.2023.36.19 . .

Measuring geopolymer set times under ionizing radiation - advances in instruments and procedures

Rubinjoni, Luka; Stanković, Srboljub; Janićijević, Aco

(Belgrade : ETRAN Society, 2023)

TY  - CONF
AU  - Rubinjoni, Luka
AU  - Stanković, Srboljub
AU  - Janićijević, Aco
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12141
AB  - Geopolymers are a class of alkali activated binders, and present a viable alternative to Portland cement. Utilization of geopolymers is a way to reduce greenhouse gas emissions and utilize secondary materials.Geopolymers are becoming a material of choice in radioactive waste conditioning, for grouting and encapsulation. Binder set times are a key parameter in determining the workability of grouts, mortars and concrete. While studying the effects of ionizing radiation on geopolymer set times, we were constrained by the configuration of the irradiation device and field, so we developed a modified Vicat apparatus, sample case/phantom, and temperature/humidity monitor. The modified procedure has allowed for a better temporal resolution of the measurements, with continuous monitoring of the experimental conditions. Fly-ash geopolymer set times under Co-60 gamma radiation are presented.
PB  - Belgrade : ETRAN Society
PB  - Belgrade : Academic Mind
C3  - IcETRAN 2023 : 10th Jubilee International Conference IcETRAN and 67th ETRAN Conference : program and book of abstracts
T1  - Measuring geopolymer set times under ionizing radiation - advances in instruments and procedures
SP  - 47
EP  - 47
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12141
ER  - 
@conference{
author = "Rubinjoni, Luka and Stanković, Srboljub and Janićijević, Aco",
year = "2023",
abstract = "Geopolymers are a class of alkali activated binders, and present a viable alternative to Portland cement. Utilization of geopolymers is a way to reduce greenhouse gas emissions and utilize secondary materials.Geopolymers are becoming a material of choice in radioactive waste conditioning, for grouting and encapsulation. Binder set times are a key parameter in determining the workability of grouts, mortars and concrete. While studying the effects of ionizing radiation on geopolymer set times, we were constrained by the configuration of the irradiation device and field, so we developed a modified Vicat apparatus, sample case/phantom, and temperature/humidity monitor. The modified procedure has allowed for a better temporal resolution of the measurements, with continuous monitoring of the experimental conditions. Fly-ash geopolymer set times under Co-60 gamma radiation are presented.",
publisher = "Belgrade : ETRAN Society, Belgrade : Academic Mind",
journal = "IcETRAN 2023 : 10th Jubilee International Conference IcETRAN and 67th ETRAN Conference : program and book of abstracts",
title = "Measuring geopolymer set times under ionizing radiation - advances in instruments and procedures",
pages = "47-47",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12141"
}
Rubinjoni, L., Stanković, S.,& Janićijević, A.. (2023). Measuring geopolymer set times under ionizing radiation - advances in instruments and procedures. in IcETRAN 2023 : 10th Jubilee International Conference IcETRAN and 67th ETRAN Conference : program and book of abstracts
Belgrade : ETRAN Society., 47-47.
https://hdl.handle.net/21.15107/rcub_vinar_12141
Rubinjoni L, Stanković S, Janićijević A. Measuring geopolymer set times under ionizing radiation - advances in instruments and procedures. in IcETRAN 2023 : 10th Jubilee International Conference IcETRAN and 67th ETRAN Conference : program and book of abstracts. 2023;:47-47.
https://hdl.handle.net/21.15107/rcub_vinar_12141 .
Rubinjoni, Luka, Stanković, Srboljub, Janićijević, Aco, "Measuring geopolymer set times under ionizing radiation - advances in instruments and procedures" in IcETRAN 2023 : 10th Jubilee International Conference IcETRAN and 67th ETRAN Conference : program and book of abstracts (2023):47-47,
https://hdl.handle.net/21.15107/rcub_vinar_12141 .

The properties of heavyweight self-compacting concrete on water penetration under pressure

Janković, Ksenija; Bojović, Dragan; Stojanović, Marko; Terzić, Anja; Stanković, Srboljub

(2023)

TY  - CONF
AU  - Janković, Ksenija
AU  - Bojović, Dragan
AU  - Stojanović, Marko
AU  - Terzić, Anja
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12161
C3  - 20th International symposium (MASE) Macedonian association of structural engineers "Resilent structures" : Proceedings book
T1  - The properties of heavyweight self-compacting concrete on water penetration under pressure
SP  - 1014
EP  - 1020
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12161
ER  - 
@conference{
author = "Janković, Ksenija and Bojović, Dragan and Stojanović, Marko and Terzić, Anja and Stanković, Srboljub",
year = "2023",
journal = "20th International symposium (MASE) Macedonian association of structural engineers "Resilent structures" : Proceedings book",
title = "The properties of heavyweight self-compacting concrete on water penetration under pressure",
pages = "1014-1020",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12161"
}
Janković, K., Bojović, D., Stojanović, M., Terzić, A.,& Stanković, S.. (2023). The properties of heavyweight self-compacting concrete on water penetration under pressure. in 20th International symposium (MASE) Macedonian association of structural engineers "Resilent structures" : Proceedings book, 1014-1020.
https://hdl.handle.net/21.15107/rcub_vinar_12161
Janković K, Bojović D, Stojanović M, Terzić A, Stanković S. The properties of heavyweight self-compacting concrete on water penetration under pressure. in 20th International symposium (MASE) Macedonian association of structural engineers "Resilent structures" : Proceedings book. 2023;:1014-1020.
https://hdl.handle.net/21.15107/rcub_vinar_12161 .
Janković, Ksenija, Bojović, Dragan, Stojanović, Marko, Terzić, Anja, Stanković, Srboljub, "The properties of heavyweight self-compacting concrete on water penetration under pressure" in 20th International symposium (MASE) Macedonian association of structural engineers "Resilent structures" : Proceedings book (2023):1014-1020,
https://hdl.handle.net/21.15107/rcub_vinar_12161 .

Comparison of gamma and X radiation attenuation characteristics for ordinary concrete, concrete with barite and concrete with limonite and steel

Janković, Ksenija; Stanković, Srboljub; Terzić, Anja; Stojanović, Marko; Bojović, Dragan

(Niš : Sievert Association, 2023)

TY  - CONF
AU  - Janković, Ksenija
AU  - Stanković, Srboljub
AU  - Terzić, Anja
AU  - Stojanović, Marko
AU  - Bojović, Dragan
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12065
AB  - During the implementation of procedures for designing building barriers for protection against gamma and X radiation, the unavoidable question of choosing construction materials with appropriate mechanical and radiation characteristics for protective barriers arises. Based on engineering practice, it is necessary to compare different types of concrete used for the construction of facilities where there are sources of gamma and X radiation, such as in cases where radiation sources appear in medical facilities with linear accelerators, cyclotron installations for accelerating nuclear particles, in the environment of nuclear reactors, in radioactive waste storages, or in radiation sterilization unit s. In the cost-benefit analysis, several criteria are used to evaluate the characteristics of the concrete, so that in addition to the mechanical characteristics, the radiation characteristics of the construction material are also considered. One of the most important characteristics of concrete for radiation protection is its total mass attenuation coefficient. In this paper, computer code XCOM was used for the calculation of the total mass attenuation coefficients in energy range from 0.01MeV to 100 MeV for three types of concrete: ordinary concrete, concrete with barite and concrete with limonite and steel. Based on the comparison of calculation results, it was concluded that concrete with limonite and steel has greater protective power than other two concrete types for the gamma and X radiation energy less than 30 keV. The second important conclusion is that the concrete with barite has greater protective power than other two concrete types in the range of photon energy from 30 keV to 300 keV, and for photon energy greater than 6 MeV. A detailed analysis of the calculation results found that in the energy range of 400 keV to 6 MeV values for the total mass attenuation coefficients are approximately the same for three different types of concrete.
PB  - Niš : Sievert Association
C3  - RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts
T1  - Comparison of gamma and X radiation attenuation  characteristics for ordinary concrete, concrete with  barite and concrete with limonite and steel
SP  - 64
EP  - 64
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12065
ER  - 
@conference{
author = "Janković, Ksenija and Stanković, Srboljub and Terzić, Anja and Stojanović, Marko and Bojović, Dragan",
year = "2023",
abstract = "During the implementation of procedures for designing building barriers for protection against gamma and X radiation, the unavoidable question of choosing construction materials with appropriate mechanical and radiation characteristics for protective barriers arises. Based on engineering practice, it is necessary to compare different types of concrete used for the construction of facilities where there are sources of gamma and X radiation, such as in cases where radiation sources appear in medical facilities with linear accelerators, cyclotron installations for accelerating nuclear particles, in the environment of nuclear reactors, in radioactive waste storages, or in radiation sterilization unit s. In the cost-benefit analysis, several criteria are used to evaluate the characteristics of the concrete, so that in addition to the mechanical characteristics, the radiation characteristics of the construction material are also considered. One of the most important characteristics of concrete for radiation protection is its total mass attenuation coefficient. In this paper, computer code XCOM was used for the calculation of the total mass attenuation coefficients in energy range from 0.01MeV to 100 MeV for three types of concrete: ordinary concrete, concrete with barite and concrete with limonite and steel. Based on the comparison of calculation results, it was concluded that concrete with limonite and steel has greater protective power than other two concrete types for the gamma and X radiation energy less than 30 keV. The second important conclusion is that the concrete with barite has greater protective power than other two concrete types in the range of photon energy from 30 keV to 300 keV, and for photon energy greater than 6 MeV. A detailed analysis of the calculation results found that in the energy range of 400 keV to 6 MeV values for the total mass attenuation coefficients are approximately the same for three different types of concrete.",
publisher = "Niš : Sievert Association",
journal = "RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts",
title = "Comparison of gamma and X radiation attenuation  characteristics for ordinary concrete, concrete with  barite and concrete with limonite and steel",
pages = "64-64",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12065"
}
Janković, K., Stanković, S., Terzić, A., Stojanović, M.,& Bojović, D.. (2023). Comparison of gamma and X radiation attenuation  characteristics for ordinary concrete, concrete with  barite and concrete with limonite and steel. in RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts
Niš : Sievert Association., 64-64.
https://hdl.handle.net/21.15107/rcub_vinar_12065
Janković K, Stanković S, Terzić A, Stojanović M, Bojović D. Comparison of gamma and X radiation attenuation  characteristics for ordinary concrete, concrete with  barite and concrete with limonite and steel. in RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts. 2023;:64-64.
https://hdl.handle.net/21.15107/rcub_vinar_12065 .
Janković, Ksenija, Stanković, Srboljub, Terzić, Anja, Stojanović, Marko, Bojović, Dragan, "Comparison of gamma and X radiation attenuation  characteristics for ordinary concrete, concrete with  barite and concrete with limonite and steel" in RAP 2023 : International conference on radiation applications in Physics, Chemistry, Biology, Medical Sciences, Engineering and Environmental Sciences; Book of abstracts (2023):64-64,
https://hdl.handle.net/21.15107/rcub_vinar_12065 .

An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts

Vasović, Nikola; Duane, Russell; Ristić, Goran; Stanković, Srboljub

(Niš : Faculty of Electronic Engineering, 2023)

TY  - CONF
AU  - Vasović, Nikola
AU  - Duane, Russell
AU  - Ristić, Goran
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12122
AB  - An improved RADFET based module dosemeter has been developed by Varadis (a spin out company of Tyndall National Institute in Cork, Ireland) with serial number RM-VT01-A. The module is based on commercially available, commercial-off-the-shelf (COTS) parts and represents an updated version of its predecessor RM-VT01 with an upper dose limit of 10Gy (1 kRad) also based on COTS parts. The RM-VT01-A module was tested to a total dose of 1kGy (100 kRad) in Co60 field at Vinča Institute of Nuclear Sciences, Belgrade, Serbia. The improved module circuit was specifically designed to address the challenge of withstanding 1 kGy (100 kRad) received dose. The primary goal of this poster is to present the improvements in the circuit design and working principle. For this purpose, eleven modules were tested, 8 powered and 3 unpowered during irradiation. The module electronics accommodates both irradiation “sense” and readout “single-current-point” mode, outputting the RADFET threshold voltage (VT) as a dosimetric information, directly proportional to the absorbed dose. The output voltage of the module was measured with a simple benchtop voltmeter to demonstrate module operation simplicity and easy system integrability. The experimental data results showed excellent agreement with the dosimetry system used at the Vinca irradiation facility, and calibration data of the VT01 RadFET part.
PB  - Niš : Faculty of Electronic Engineering
C3  - ELICSIR Project Symposium : Book of abstracts
T1  - An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts
SP  - 49
EP  - 49
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12122
ER  - 
@conference{
author = "Vasović, Nikola and Duane, Russell and Ristić, Goran and Stanković, Srboljub",
year = "2023",
abstract = "An improved RADFET based module dosemeter has been developed by Varadis (a spin out company of Tyndall National Institute in Cork, Ireland) with serial number RM-VT01-A. The module is based on commercially available, commercial-off-the-shelf (COTS) parts and represents an updated version of its predecessor RM-VT01 with an upper dose limit of 10Gy (1 kRad) also based on COTS parts. The RM-VT01-A module was tested to a total dose of 1kGy (100 kRad) in Co60 field at Vinča Institute of Nuclear Sciences, Belgrade, Serbia. The improved module circuit was specifically designed to address the challenge of withstanding 1 kGy (100 kRad) received dose. The primary goal of this poster is to present the improvements in the circuit design and working principle. For this purpose, eleven modules were tested, 8 powered and 3 unpowered during irradiation. The module electronics accommodates both irradiation “sense” and readout “single-current-point” mode, outputting the RADFET threshold voltage (VT) as a dosimetric information, directly proportional to the absorbed dose. The output voltage of the module was measured with a simple benchtop voltmeter to demonstrate module operation simplicity and easy system integrability. The experimental data results showed excellent agreement with the dosimetry system used at the Vinca irradiation facility, and calibration data of the VT01 RadFET part.",
publisher = "Niš : Faculty of Electronic Engineering",
journal = "ELICSIR Project Symposium : Book of abstracts",
title = "An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts",
pages = "49-49",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12122"
}
Vasović, N., Duane, R., Ristić, G.,& Stanković, S.. (2023). An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts. in ELICSIR Project Symposium : Book of abstracts
Niš : Faculty of Electronic Engineering., 49-49.
https://hdl.handle.net/21.15107/rcub_vinar_12122
Vasović N, Duane R, Ristić G, Stanković S. An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts. in ELICSIR Project Symposium : Book of abstracts. 2023;:49-49.
https://hdl.handle.net/21.15107/rcub_vinar_12122 .
Vasović, Nikola, Duane, Russell, Ristić, Goran, Stanković, Srboljub, "An improved RADFET-based module with an extended dose range of 1 kGy TID based on COTS parts" in ELICSIR Project Symposium : Book of abstracts (2023):49-49,
https://hdl.handle.net/21.15107/rcub_vinar_12122 .

Application of coal combustion byproducts in self-compacting concrete: influence on flowability

Janković, Ksenija; Stojanović, Marko; Bojović, Dragan; Terzić, Anja; Stanković, Srboljub

(University of Belgrade, Technical Faculty in Bor, 2023)

TY  - CONF
AU  - Janković, Ksenija
AU  - Stojanović, Marko
AU  - Bojović, Dragan
AU  - Terzić, Anja
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11177
AB  - Compared to traditional concrete, self-compacting concrete (SCC) demonstrates greater flowability, which is achieved by including an extra high percentage of ultra-fine particles. As a result, the required high paste content is obtained while the cement content is strictly limited. The coal combustion byproduct (fly ash) is one of the most efficient SCC fillers because it extends the lifecycle of SCC by improving its microstructural properties, strength, and durability. In this study, the amounts of fly ash in SCC compositions varied. The changes in physical and mechanical characteristics of fresh SCC samples related to variations in the water/binder ratio were monitored
PB  - University of Belgrade, Technical Faculty in Bor
C3  - IMPRC : 15th International Mineral Processing and Recycling Conference : Proceedings
T1  - Application of coal combustion byproducts in self-compacting concrete: influence on flowability
SP  - 579
EP  - 584
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11177
ER  - 
@conference{
author = "Janković, Ksenija and Stojanović, Marko and Bojović, Dragan and Terzić, Anja and Stanković, Srboljub",
year = "2023",
abstract = "Compared to traditional concrete, self-compacting concrete (SCC) demonstrates greater flowability, which is achieved by including an extra high percentage of ultra-fine particles. As a result, the required high paste content is obtained while the cement content is strictly limited. The coal combustion byproduct (fly ash) is one of the most efficient SCC fillers because it extends the lifecycle of SCC by improving its microstructural properties, strength, and durability. In this study, the amounts of fly ash in SCC compositions varied. The changes in physical and mechanical characteristics of fresh SCC samples related to variations in the water/binder ratio were monitored",
publisher = "University of Belgrade, Technical Faculty in Bor",
journal = "IMPRC : 15th International Mineral Processing and Recycling Conference : Proceedings",
title = "Application of coal combustion byproducts in self-compacting concrete: influence on flowability",
pages = "579-584",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11177"
}
Janković, K., Stojanović, M., Bojović, D., Terzić, A.,& Stanković, S.. (2023). Application of coal combustion byproducts in self-compacting concrete: influence on flowability. in IMPRC : 15th International Mineral Processing and Recycling Conference : Proceedings
University of Belgrade, Technical Faculty in Bor., 579-584.
https://hdl.handle.net/21.15107/rcub_vinar_11177
Janković K, Stojanović M, Bojović D, Terzić A, Stanković S. Application of coal combustion byproducts in self-compacting concrete: influence on flowability. in IMPRC : 15th International Mineral Processing and Recycling Conference : Proceedings. 2023;:579-584.
https://hdl.handle.net/21.15107/rcub_vinar_11177 .
Janković, Ksenija, Stojanović, Marko, Bojović, Dragan, Terzić, Anja, Stanković, Srboljub, "Application of coal combustion byproducts in self-compacting concrete: influence on flowability" in IMPRC : 15th International Mineral Processing and Recycling Conference : Proceedings (2023):579-584,
https://hdl.handle.net/21.15107/rcub_vinar_11177 .

Influence of Aggregate Type on the Properties on SCC with Fly Ash

Janković, Ksenija; Stojanović, Marko; Bojović, Dragan; Terzić, Anja; Stanković, Srboljub

(2023)

TY  - CONF
AU  - Janković, Ksenija
AU  - Stojanović, Marko
AU  - Bojović, Dragan
AU  - Terzić, Anja
AU  - Stanković, Srboljub
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11172
AB  - This study compared the performance of self-compacting concrete (SCC) based on fly ash addition and limestone filler. A SCC prepared with Portland cement, river sand, and limestone filler was used as a reference sample. Additional experimental self-compacting concretes with different types of fine aggregates, fillers, and special additives for increasing freeze-thaw resistance were prepared and optimized. The correlation between mix design, i.e., percentage of barite sand and additives, and properties of fresh SCC (slump-flow test, V-funnel test, and L-box test), as well as properties of hardened SCC (compressive strengths), were investigated and discussed.
C3  - International RILEM Conference on Synergising Expertise towards Sustainability and Robustness of Cement-based Materials and Concrete Structures
T1  - Influence of Aggregate Type on the Properties on SCC with Fly Ash
SP  - 47
EP  - 54
DO  - 10.1007/978-3-031-33187-9_5
ER  - 
@conference{
author = "Janković, Ksenija and Stojanović, Marko and Bojović, Dragan and Terzić, Anja and Stanković, Srboljub",
year = "2023",
abstract = "This study compared the performance of self-compacting concrete (SCC) based on fly ash addition and limestone filler. A SCC prepared with Portland cement, river sand, and limestone filler was used as a reference sample. Additional experimental self-compacting concretes with different types of fine aggregates, fillers, and special additives for increasing freeze-thaw resistance were prepared and optimized. The correlation between mix design, i.e., percentage of barite sand and additives, and properties of fresh SCC (slump-flow test, V-funnel test, and L-box test), as well as properties of hardened SCC (compressive strengths), were investigated and discussed.",
journal = "International RILEM Conference on Synergising Expertise towards Sustainability and Robustness of Cement-based Materials and Concrete Structures",
title = "Influence of Aggregate Type on the Properties on SCC with Fly Ash",
pages = "47-54",
doi = "10.1007/978-3-031-33187-9_5"
}
Janković, K., Stojanović, M., Bojović, D., Terzić, A.,& Stanković, S.. (2023). Influence of Aggregate Type on the Properties on SCC with Fly Ash. in International RILEM Conference on Synergising Expertise towards Sustainability and Robustness of Cement-based Materials and Concrete Structures, 47-54.
https://doi.org/10.1007/978-3-031-33187-9_5
Janković K, Stojanović M, Bojović D, Terzić A, Stanković S. Influence of Aggregate Type on the Properties on SCC with Fly Ash. in International RILEM Conference on Synergising Expertise towards Sustainability and Robustness of Cement-based Materials and Concrete Structures. 2023;:47-54.
doi:10.1007/978-3-031-33187-9_5 .
Janković, Ksenija, Stojanović, Marko, Bojović, Dragan, Terzić, Anja, Stanković, Srboljub, "Influence of Aggregate Type on the Properties on SCC with Fly Ash" in International RILEM Conference on Synergising Expertise towards Sustainability and Robustness of Cement-based Materials and Concrete Structures (2023):47-54,
https://doi.org/10.1007/978-3-031-33187-9_5 . .

Heavyweight Ultra-High-Performance Concrete with Micro-Reinforcement

Janković, Ksenija; Stanković, Srboljub; Bojović, Dragan; Stojanović, Marko; Antić Aranđelović, Lana; Terzić, Anja

(Belgrade : Serbian Ceramic Society, 2023)

TY  - CONF
AU  - Janković, Ksenija
AU  - Stanković, Srboljub
AU  - Bojović, Dragan
AU  - Stojanović, Marko
AU  - Antić Aranđelović, Lana
AU  - Terzić, Anja
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11650
AB  - The impacts of nano-silica addition, steel micro-reinforcement, and aggregate type on the mechanical properties and durability of ultra-high-performance concrete (UHPC) were studied. As aggregates, quartz and barite were used. The amounts of steel fibers and nanosilica were alternated. Six concrete mixes were produced with quartz sand, and the remaining six concrete mixes were designed with barite sand. Fibers made about 3-5% of the concrete composition’s mass. In a 2-5% concentration, nano-silica was used as a cement replacement. The inclusion of nano-silica significantly boosted the compressive strength of UHPC. The compressive and flexural strengths were also positively impacted by fiber supplementation ranging from 3% to 5%. The amount of fiber utilized proved to be more influential than the aggregate used. The UHPC concrete's durability was increased as all samples were highly resistant to freezing and thawing cycles. UHPC designed with barite aggregate demonstrated good X and gamma ray absorption at energies below 300 keV.
PB  - Belgrade : Serbian Ceramic Society
C3  - Advanced Ceramics and Application :11th Serbian Ceramic Society Conference : program and the book of abstracts; September 18-20, 2023; Belgrade
T1  - Heavyweight Ultra-High-Performance Concrete with Micro-Reinforcement
SP  - 83
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11650
ER  - 
@conference{
author = "Janković, Ksenija and Stanković, Srboljub and Bojović, Dragan and Stojanović, Marko and Antić Aranđelović, Lana and Terzić, Anja",
year = "2023",
abstract = "The impacts of nano-silica addition, steel micro-reinforcement, and aggregate type on the mechanical properties and durability of ultra-high-performance concrete (UHPC) were studied. As aggregates, quartz and barite were used. The amounts of steel fibers and nanosilica were alternated. Six concrete mixes were produced with quartz sand, and the remaining six concrete mixes were designed with barite sand. Fibers made about 3-5% of the concrete composition’s mass. In a 2-5% concentration, nano-silica was used as a cement replacement. The inclusion of nano-silica significantly boosted the compressive strength of UHPC. The compressive and flexural strengths were also positively impacted by fiber supplementation ranging from 3% to 5%. The amount of fiber utilized proved to be more influential than the aggregate used. The UHPC concrete's durability was increased as all samples were highly resistant to freezing and thawing cycles. UHPC designed with barite aggregate demonstrated good X and gamma ray absorption at energies below 300 keV.",
publisher = "Belgrade : Serbian Ceramic Society",
journal = "Advanced Ceramics and Application :11th Serbian Ceramic Society Conference : program and the book of abstracts; September 18-20, 2023; Belgrade",
title = "Heavyweight Ultra-High-Performance Concrete with Micro-Reinforcement",
pages = "83",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11650"
}
Janković, K., Stanković, S., Bojović, D., Stojanović, M., Antić Aranđelović, L.,& Terzić, A.. (2023). Heavyweight Ultra-High-Performance Concrete with Micro-Reinforcement. in Advanced Ceramics and Application :11th Serbian Ceramic Society Conference : program and the book of abstracts; September 18-20, 2023; Belgrade
Belgrade : Serbian Ceramic Society., 83.
https://hdl.handle.net/21.15107/rcub_vinar_11650
Janković K, Stanković S, Bojović D, Stojanović M, Antić Aranđelović L, Terzić A. Heavyweight Ultra-High-Performance Concrete with Micro-Reinforcement. in Advanced Ceramics and Application :11th Serbian Ceramic Society Conference : program and the book of abstracts; September 18-20, 2023; Belgrade. 2023;:83.
https://hdl.handle.net/21.15107/rcub_vinar_11650 .
Janković, Ksenija, Stanković, Srboljub, Bojović, Dragan, Stojanović, Marko, Antić Aranđelović, Lana, Terzić, Anja, "Heavyweight Ultra-High-Performance Concrete with Micro-Reinforcement" in Advanced Ceramics and Application :11th Serbian Ceramic Society Conference : program and the book of abstracts; September 18-20, 2023; Belgrade (2023):83,
https://hdl.handle.net/21.15107/rcub_vinar_11650 .

Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu

Grahovac, Nebojša; Pavkov, Vladimir; Stanković, Srboljub; Matović, Branko

(2022)

TY  - PAT
AU  - Grahovac, Nebojša
AU  - Pavkov, Vladimir
AU  - Stanković, Srboljub
AU  - Matović, Branko
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11660
AB  - Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu je u primeni otpornosti na habanje reznog alata sa dijamantskom prevlakom i površinske hrapavosti obrađivanih površinana definisanje optimalnih režima obrade pomenutih materijala na CNC strugu. Postupak se sastoji od tri faze: 1. Određivanje krive habanja alata sa dijamantskom prevlakom pri mašinskoj obradi legure i kompozita na strugu. 2. Određivanje dijagrama površinske hrapavosti za dati rezni alat. 3. Analiza reznih ivica dijamantskog alata primenom skenirajućeg elektronskog mikroskopa (SEM).
AB  - The procedure for application of cutting tools with diamond coating in the processing of Al-12% Si alloy and glass fiber / polyester resin composites on lathe is in the application of wear resistance of cutting tools with diamond coating and surface roughness of machined surfaces defining optimal processing modes. The procedure consists of three phases: 1. Determination of the wear curve of tools with diamond coating during machining of alloys and composites on a lathe. 2. Determining the surface roughness diagram for a given cutting tool. 3. Analysis of cutting edges of diamond tools using scanning electron microscope (SEM).
T2  - Zavod za intelektualnu svojinu Republike Srbije
T1  - Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu
T1  - Procedure for application of cutting tools with diamond coating in the processing of Al-12% Si alloy and glass fiber / polyester resin composites on lathe
VL  - 102
IS  - 7
SP  - 8
EP  - 8
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11660
ER  - 
@misc{
author = "Grahovac, Nebojša and Pavkov, Vladimir and Stanković, Srboljub and Matović, Branko",
year = "2022",
abstract = "Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu je u primeni otpornosti na habanje reznog alata sa dijamantskom prevlakom i površinske hrapavosti obrađivanih površinana definisanje optimalnih režima obrade pomenutih materijala na CNC strugu. Postupak se sastoji od tri faze: 1. Određivanje krive habanja alata sa dijamantskom prevlakom pri mašinskoj obradi legure i kompozita na strugu. 2. Određivanje dijagrama površinske hrapavosti za dati rezni alat. 3. Analiza reznih ivica dijamantskog alata primenom skenirajućeg elektronskog mikroskopa (SEM)., The procedure for application of cutting tools with diamond coating in the processing of Al-12% Si alloy and glass fiber / polyester resin composites on lathe is in the application of wear resistance of cutting tools with diamond coating and surface roughness of machined surfaces defining optimal processing modes. The procedure consists of three phases: 1. Determination of the wear curve of tools with diamond coating during machining of alloys and composites on a lathe. 2. Determining the surface roughness diagram for a given cutting tool. 3. Analysis of cutting edges of diamond tools using scanning electron microscope (SEM).",
journal = "Zavod za intelektualnu svojinu Republike Srbije",
title = "Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu, Procedure for application of cutting tools with diamond coating in the processing of Al-12% Si alloy and glass fiber / polyester resin composites on lathe",
volume = "102",
number = "7",
pages = "8-8",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11660"
}
Grahovac, N., Pavkov, V., Stanković, S.,& Matović, B.. (2022). Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu. in Zavod za intelektualnu svojinu Republike Srbije, 102(7), 8-8.
https://hdl.handle.net/21.15107/rcub_vinar_11660
Grahovac N, Pavkov V, Stanković S, Matović B. Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu. in Zavod za intelektualnu svojinu Republike Srbije. 2022;102(7):8-8.
https://hdl.handle.net/21.15107/rcub_vinar_11660 .
Grahovac, Nebojša, Pavkov, Vladimir, Stanković, Srboljub, Matović, Branko, "Postupak primene reznog alata sa dijamantskom prevlakom pri obradi legure Al-12%Si i kompozita staklena vlakna/poliesterska smola na strugu" in Zavod za intelektualnu svojinu Republike Srbije, 102, no. 7 (2022):8-8,
https://hdl.handle.net/21.15107/rcub_vinar_11660 .

Commercial P-Channel Power VDMOSFET as X-ray Dosimeter

Ristić, Goran S.; Ilić, Stefan; Veljković, Sandra; Jevtić, Aleksandar S.; Dimitrijević, Strahinja; Palma, Alberto J.; Stanković, Srboljub; Anđelković, Marko S.

(2022)

TY  - JOUR
AU  - Ristić, Goran S.
AU  - Ilić, Stefan
AU  - Veljković, Sandra
AU  - Jevtić, Aleksandar S.
AU  - Dimitrijević, Strahinja
AU  - Palma, Alberto J.
AU  - Stanković, Srboljub
AU  - Anđelković, Marko S.
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10240
AB  - The possibility of using commercial p-channel power vertical double-diffused metal-oxide-semiconductor field-effect transistors (VDMOSFETs) as X-ray sensors is investigated in this case study. In this aspect, the dependence of sensitivity on both the gate voltage and the mean energy for three X-ray beams is examined. The eight gate voltages from 0 to 21 V are applied, and the dependence of the sensitivity on the gate voltage is well fitted using the proposed equation. Regarding X-ray energy, the sensitivity first increases and then decreases as a consequence of the behavior of the mass energy-absorption coefficients and is the largest for RQR8 beam. As the mass energy-absorption coefficients of SiO2 are not found in the literature, the mass energy-absorption coefficients of silicon are used. The behavior of irradiated transistors during annealing at room temperature without gate polarization is also considered.
T2  - Electronics
T1  - Commercial P-Channel Power VDMOSFET as X-ray Dosimeter
VL  - 11
IS  - 6
SP  - 918
DO  - 10.3390/electronics11060918
ER  - 
@article{
author = "Ristić, Goran S. and Ilić, Stefan and Veljković, Sandra and Jevtić, Aleksandar S. and Dimitrijević, Strahinja and Palma, Alberto J. and Stanković, Srboljub and Anđelković, Marko S.",
year = "2022",
abstract = "The possibility of using commercial p-channel power vertical double-diffused metal-oxide-semiconductor field-effect transistors (VDMOSFETs) as X-ray sensors is investigated in this case study. In this aspect, the dependence of sensitivity on both the gate voltage and the mean energy for three X-ray beams is examined. The eight gate voltages from 0 to 21 V are applied, and the dependence of the sensitivity on the gate voltage is well fitted using the proposed equation. Regarding X-ray energy, the sensitivity first increases and then decreases as a consequence of the behavior of the mass energy-absorption coefficients and is the largest for RQR8 beam. As the mass energy-absorption coefficients of SiO2 are not found in the literature, the mass energy-absorption coefficients of silicon are used. The behavior of irradiated transistors during annealing at room temperature without gate polarization is also considered.",
journal = "Electronics",
title = "Commercial P-Channel Power VDMOSFET as X-ray Dosimeter",
volume = "11",
number = "6",
pages = "918",
doi = "10.3390/electronics11060918"
}
Ristić, G. S., Ilić, S., Veljković, S., Jevtić, A. S., Dimitrijević, S., Palma, A. J., Stanković, S.,& Anđelković, M. S.. (2022). Commercial P-Channel Power VDMOSFET as X-ray Dosimeter. in Electronics, 11(6), 918.
https://doi.org/10.3390/electronics11060918
Ristić GS, Ilić S, Veljković S, Jevtić AS, Dimitrijević S, Palma AJ, Stanković S, Anđelković MS. Commercial P-Channel Power VDMOSFET as X-ray Dosimeter. in Electronics. 2022;11(6):918.
doi:10.3390/electronics11060918 .
Ristić, Goran S., Ilić, Stefan, Veljković, Sandra, Jevtić, Aleksandar S., Dimitrijević, Strahinja, Palma, Alberto J., Stanković, Srboljub, Anđelković, Marko S., "Commercial P-Channel Power VDMOSFET as X-ray Dosimeter" in Electronics, 11, no. 6 (2022):918,
https://doi.org/10.3390/electronics11060918 . .
6
2

Stacked floating gate MOSFET as a passive dosimeter

Ilić, Stefan D.; Anđelković, Marko; Carvajal, Miguel Ángel; Duane, Russell; Sarajlić, Milija; Stanković, Srboljub; Ristić, Goran

(RAD Centre, Niš, Serbia, 2022)

TY  - CONF
AU  - Ilić, Stefan D.
AU  - Anđelković, Marko
AU  - Carvajal, Miguel Ángel
AU  - Duane, Russell
AU  - Sarajlić, Milija
AU  - Stanković, Srboljub
AU  - Ristić, Goran
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11117
AB  - Introduction. The approach to increase the sensitivity of semiconductor radiation dosimeter with a stacked design was presented for the thick oxide pMOS transistors, also known as RadFETs (A. Kelleher et al., IEEE transactions on nuclear science 42, 1995). The sensitivity is increasing with the number of RadFETs in stacked structure, but there were limitations because of the diode reverse breakdown voltage during readout current (B. O’Connell et al., In Proceedings of the Third European Conference on Radiation and its Effects on Components and Systems, 1995). Further improvement of the stacked RadFETs device enables detecting a minimum absorbed dose of less than 50 Gy for a 20 V power supply (B. O’Connell et al., Fifth European Conference on Radiation and Its Effects on Components and Systems, 1999). Floating gate MOSFET is a modified structure of MOSFET with another polysilicon gate surrounded by oxide. The advantages of the floating gate MOSFET as a radiation dosimeter are that it does not require thick oxide fabrication and the highest sensitivity is for the zero-bias at the control gate during irradiation (S. Ilić et al., Sensors 20 (11), 2020). Experimental setup. Commercial floating gate MOSFETs designed by Advanced Linear Devices Inc. were used in this paper. Four transistors were connected in the stacked structure (drain and control gate are shorted and connected to the source of the next stacked transistor), and their threshold voltage drift values were measured before and after each irradiation portion with the same conditions. The experiment was performed at the Institute of Nuclear Sciences “Vinča”, Belgrade, Serbia. Radiation source Co-60 was used for irradiation of the components, with the following portions of the absorbed dose (Si): 10 Gy, 10 Gy, 10 Gy, 20 Gy, 50 Gy, 400 Gy, 500 Gy, 4 mGy, 45 mGy, 50 mGy, respectively (absorbed dose was 100 mGy in total). All measurements were performed in a test fixture with triax cables by Keithley 2636A Source Measure Unit. During irradiation, all stacked transistors were zero-biased. Results. Observing the threshold voltage drift of the four stacked floating gate MOS transistors, we noticed that the stack of two transistors has the most stable reading values over time (smallest drift). Considering this, we analyzed only two stacked floating gate MOS transistors as a passive dosimeter for the low doses. The results show that it is possible to detect the first portion of 10 Gy at which the sensitivity of the two stacked transistors is 23 V/Gy. For the next same portion, the sensitivity is 17 V/Gy, while for the third, the value is 7 V/Gy. However, for the next 20 Gy, there is a tiny shift, and the sensitivity is only 1 V/Gy. Decreased sensitivity with absorbed dose is a feature of the floating gate MOSFET that has been observed before for much higher doses (S. Ilić et al., Sensors 20 (11), 2020). There is a large overlap in the threshold voltage drift values for the next four radiation portions. However, for the last two largest portions, 45 and 50 mGy, there is a significant threshold voltage shift with no overlapping, and thus it is possible to determine the sensitivity of 0.0226 and 0.0214 V/Gy, respectively. Conclusions. Using a floating gate MOSFET as a low-dose passive dosimeter is possible, but recharging the floating gate and reusing this device for higher total ionizing doses should be investigated.
PB  - RAD Centre, Niš, Serbia
C3  - RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro
T1  - Stacked floating gate MOSFET as a passive dosimeter
SP  - 113
DO  - 10.21175/rad.spr.abstr.book.2022.26.12
ER  - 
@conference{
author = "Ilić, Stefan D. and Anđelković, Marko and Carvajal, Miguel Ángel and Duane, Russell and Sarajlić, Milija and Stanković, Srboljub and Ristić, Goran",
year = "2022",
abstract = "Introduction. The approach to increase the sensitivity of semiconductor radiation dosimeter with a stacked design was presented for the thick oxide pMOS transistors, also known as RadFETs (A. Kelleher et al., IEEE transactions on nuclear science 42, 1995). The sensitivity is increasing with the number of RadFETs in stacked structure, but there were limitations because of the diode reverse breakdown voltage during readout current (B. O’Connell et al., In Proceedings of the Third European Conference on Radiation and its Effects on Components and Systems, 1995). Further improvement of the stacked RadFETs device enables detecting a minimum absorbed dose of less than 50 Gy for a 20 V power supply (B. O’Connell et al., Fifth European Conference on Radiation and Its Effects on Components and Systems, 1999). Floating gate MOSFET is a modified structure of MOSFET with another polysilicon gate surrounded by oxide. The advantages of the floating gate MOSFET as a radiation dosimeter are that it does not require thick oxide fabrication and the highest sensitivity is for the zero-bias at the control gate during irradiation (S. Ilić et al., Sensors 20 (11), 2020). Experimental setup. Commercial floating gate MOSFETs designed by Advanced Linear Devices Inc. were used in this paper. Four transistors were connected in the stacked structure (drain and control gate are shorted and connected to the source of the next stacked transistor), and their threshold voltage drift values were measured before and after each irradiation portion with the same conditions. The experiment was performed at the Institute of Nuclear Sciences “Vinča”, Belgrade, Serbia. Radiation source Co-60 was used for irradiation of the components, with the following portions of the absorbed dose (Si): 10 Gy, 10 Gy, 10 Gy, 20 Gy, 50 Gy, 400 Gy, 500 Gy, 4 mGy, 45 mGy, 50 mGy, respectively (absorbed dose was 100 mGy in total). All measurements were performed in a test fixture with triax cables by Keithley 2636A Source Measure Unit. During irradiation, all stacked transistors were zero-biased. Results. Observing the threshold voltage drift of the four stacked floating gate MOS transistors, we noticed that the stack of two transistors has the most stable reading values over time (smallest drift). Considering this, we analyzed only two stacked floating gate MOS transistors as a passive dosimeter for the low doses. The results show that it is possible to detect the first portion of 10 Gy at which the sensitivity of the two stacked transistors is 23 V/Gy. For the next same portion, the sensitivity is 17 V/Gy, while for the third, the value is 7 V/Gy. However, for the next 20 Gy, there is a tiny shift, and the sensitivity is only 1 V/Gy. Decreased sensitivity with absorbed dose is a feature of the floating gate MOSFET that has been observed before for much higher doses (S. Ilić et al., Sensors 20 (11), 2020). There is a large overlap in the threshold voltage drift values for the next four radiation portions. However, for the last two largest portions, 45 and 50 mGy, there is a significant threshold voltage shift with no overlapping, and thus it is possible to determine the sensitivity of 0.0226 and 0.0214 V/Gy, respectively. Conclusions. Using a floating gate MOSFET as a low-dose passive dosimeter is possible, but recharging the floating gate and reusing this device for higher total ionizing doses should be investigated.",
publisher = "RAD Centre, Niš, Serbia",
journal = "RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro",
title = "Stacked floating gate MOSFET as a passive dosimeter",
pages = "113",
doi = "10.21175/rad.spr.abstr.book.2022.26.12"
}
Ilić, S. D., Anđelković, M., Carvajal, M. Á., Duane, R., Sarajlić, M., Stanković, S.,& Ristić, G.. (2022). Stacked floating gate MOSFET as a passive dosimeter. in RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro
RAD Centre, Niš, Serbia., 113.
https://doi.org/10.21175/rad.spr.abstr.book.2022.26.12
Ilić SD, Anđelković M, Carvajal MÁ, Duane R, Sarajlić M, Stanković S, Ristić G. Stacked floating gate MOSFET as a passive dosimeter. in RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro. 2022;:113.
doi:10.21175/rad.spr.abstr.book.2022.26.12 .
Ilić, Stefan D., Anđelković, Marko, Carvajal, Miguel Ángel, Duane, Russell, Sarajlić, Milija, Stanković, Srboljub, Ristić, Goran, "Stacked floating gate MOSFET as a passive dosimeter" in RAD 2022 : 10th Jubilee International Conference on Radiation in Various Fields of Research : book of abstracts; June 13-17; Herceg Novi, Montenegro (2022):113,
https://doi.org/10.21175/rad.spr.abstr.book.2022.26.12 . .

Response of Commercial P-Channel Power VDMOS Transistors to Ionizing Irradiation and Bias Temperature Stress

Veljković, Sandra; Mitrović, Nikola; Davidović, Vojkan; Golubović, Snežana; Djorić-Veljković, Snežana; Paskaleva, Albena; Spassov, Dencho; Stanković, Srboljub; Andjelković, Marko; Prijić, Zoran; Manić, Ivica; Prijić, Aneta; Ristić, Goran; Danković, Danijel

(2022)

TY  - JOUR
AU  - Veljković, Sandra
AU  - Mitrović, Nikola
AU  - Davidović, Vojkan
AU  - Golubović, Snežana
AU  - Djorić-Veljković, Snežana
AU  - Paskaleva, Albena
AU  - Spassov, Dencho
AU  - Stanković, Srboljub
AU  - Andjelković, Marko
AU  - Prijić, Zoran
AU  - Manić, Ivica
AU  - Prijić, Aneta
AU  - Ristić, Goran
AU  - Danković, Danijel
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12130
AB  - n this paper, the e®ects of successively applied static/pulsed negative bias temperature (NBT)stress and irradiation on commercial p-channel power vertical double-di®used metal-oxidesemiconductor (VDMOS) transistors are investigated. To further illustrate the impacts of thesestresses on the power devices, the relative contributions of gate oxide charge (Not) and interfacetraps (Nit) to threshold voltage shifts are shown and studied. It was shown that when irradi-ation without gate voltage is used, the duration of the pre-irradiation static NBT stress has aslightly larger e®ect on the radiation response of power VDMOS transistors. Regarding the factthat the investigated components are more likely to function in the dynamic mode than thestatic mode in practice, additional analysis was focused on the results obtained during thepulsed NBT stress after irradiation. For the components subjected to the pulsed NBT stressafter the irradiation, the e®ects ofNotneutralization andNitpassivation (usually related toannealing) are more enhanced than the components subjected to the static NBT stress, becauseonly a high temperature is applied during the pulse-o® state. It was observed that in devicespreviously irradiated with gate voltage applied, the decrease of threshold voltage shift is sig-ni ̄cantly greater during the pulsed NBT stress than during the static NBT stress
T2  - Journal of Circuits, Systems and Computers
T1  - Response of Commercial P-Channel Power VDMOS Transistors to Ionizing Irradiation and Bias Temperature Stress
VL  - 31
IS  - 18
SP  - 2240003
DO  - 10.1142/S0218126622400035
ER  - 
@article{
author = "Veljković, Sandra and Mitrović, Nikola and Davidović, Vojkan and Golubović, Snežana and Djorić-Veljković, Snežana and Paskaleva, Albena and Spassov, Dencho and Stanković, Srboljub and Andjelković, Marko and Prijić, Zoran and Manić, Ivica and Prijić, Aneta and Ristić, Goran and Danković, Danijel",
year = "2022",
abstract = "n this paper, the e®ects of successively applied static/pulsed negative bias temperature (NBT)stress and irradiation on commercial p-channel power vertical double-di®used metal-oxidesemiconductor (VDMOS) transistors are investigated. To further illustrate the impacts of thesestresses on the power devices, the relative contributions of gate oxide charge (Not) and interfacetraps (Nit) to threshold voltage shifts are shown and studied. It was shown that when irradi-ation without gate voltage is used, the duration of the pre-irradiation static NBT stress has aslightly larger e®ect on the radiation response of power VDMOS transistors. Regarding the factthat the investigated components are more likely to function in the dynamic mode than thestatic mode in practice, additional analysis was focused on the results obtained during thepulsed NBT stress after irradiation. For the components subjected to the pulsed NBT stressafter the irradiation, the e®ects ofNotneutralization andNitpassivation (usually related toannealing) are more enhanced than the components subjected to the static NBT stress, becauseonly a high temperature is applied during the pulse-o® state. It was observed that in devicespreviously irradiated with gate voltage applied, the decrease of threshold voltage shift is sig-ni ̄cantly greater during the pulsed NBT stress than during the static NBT stress",
journal = "Journal of Circuits, Systems and Computers",
title = "Response of Commercial P-Channel Power VDMOS Transistors to Ionizing Irradiation and Bias Temperature Stress",
volume = "31",
number = "18",
pages = "2240003",
doi = "10.1142/S0218126622400035"
}
Veljković, S., Mitrović, N., Davidović, V., Golubović, S., Djorić-Veljković, S., Paskaleva, A., Spassov, D., Stanković, S., Andjelković, M., Prijić, Z., Manić, I., Prijić, A., Ristić, G.,& Danković, D.. (2022). Response of Commercial P-Channel Power VDMOS Transistors to Ionizing Irradiation and Bias Temperature Stress. in Journal of Circuits, Systems and Computers, 31(18), 2240003.
https://doi.org/10.1142/S0218126622400035
Veljković S, Mitrović N, Davidović V, Golubović S, Djorić-Veljković S, Paskaleva A, Spassov D, Stanković S, Andjelković M, Prijić Z, Manić I, Prijić A, Ristić G, Danković D. Response of Commercial P-Channel Power VDMOS Transistors to Ionizing Irradiation and Bias Temperature Stress. in Journal of Circuits, Systems and Computers. 2022;31(18):2240003.
doi:10.1142/S0218126622400035 .
Veljković, Sandra, Mitrović, Nikola, Davidović, Vojkan, Golubović, Snežana, Djorić-Veljković, Snežana, Paskaleva, Albena, Spassov, Dencho, Stanković, Srboljub, Andjelković, Marko, Prijić, Zoran, Manić, Ivica, Prijić, Aneta, Ristić, Goran, Danković, Danijel, "Response of Commercial P-Channel Power VDMOS Transistors to Ionizing Irradiation and Bias Temperature Stress" in Journal of Circuits, Systems and Computers, 31, no. 18 (2022):2240003,
https://doi.org/10.1142/S0218126622400035 . .
2

Impact of fine aggregate particle size and morphology on the early strengths of SCC

Janković, Ksenija; Stojanović, Marko; Terzić, Anja; Bojović, Dragan; Stanković, Srboljub

(2022)

TY  - CONF
AU  - Janković, Ksenija
AU  - Stojanović, Marko
AU  - Terzić, Anja
AU  - Bojović, Dragan
AU  - Stanković, Srboljub
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12134
AB  - A comparative study of performances of self compacting concrete (SCC) with fly ash and limestone filler was conducted. The experimental program included the production of reference SCC designed with Portland cement, river sand and limestone filler and four experimental self compacting concretes with different types of fine aggregates, fillers and special additive to increase freeze-thaw resistance. The effects that different sand and additions have on the properties of fresh SCC (slump-flow test, V-funnel test, and L-box test) and compressive strengths in early ages (3 and 7 days) were investigated and discussed.
C3  - 16th International Congress of Association of Structural Engineers of Serbia : Proceedings
T1  - Impact of fine aggregate particle size and morphology on the early strengths of SCC
SP  - 422
EP  - 429
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12134
ER  - 
@conference{
author = "Janković, Ksenija and Stojanović, Marko and Terzić, Anja and Bojović, Dragan and Stanković, Srboljub",
year = "2022",
abstract = "A comparative study of performances of self compacting concrete (SCC) with fly ash and limestone filler was conducted. The experimental program included the production of reference SCC designed with Portland cement, river sand and limestone filler and four experimental self compacting concretes with different types of fine aggregates, fillers and special additive to increase freeze-thaw resistance. The effects that different sand and additions have on the properties of fresh SCC (slump-flow test, V-funnel test, and L-box test) and compressive strengths in early ages (3 and 7 days) were investigated and discussed.",
journal = "16th International Congress of Association of Structural Engineers of Serbia : Proceedings",
title = "Impact of fine aggregate particle size and morphology on the early strengths of SCC",
pages = "422-429",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12134"
}
Janković, K., Stojanović, M., Terzić, A., Bojović, D.,& Stanković, S.. (2022). Impact of fine aggregate particle size and morphology on the early strengths of SCC. in 16th International Congress of Association of Structural Engineers of Serbia : Proceedings, 422-429.
https://hdl.handle.net/21.15107/rcub_vinar_12134
Janković K, Stojanović M, Terzić A, Bojović D, Stanković S. Impact of fine aggregate particle size and morphology on the early strengths of SCC. in 16th International Congress of Association of Structural Engineers of Serbia : Proceedings. 2022;:422-429.
https://hdl.handle.net/21.15107/rcub_vinar_12134 .
Janković, Ksenija, Stojanović, Marko, Terzić, Anja, Bojović, Dragan, Stanković, Srboljub, "Impact of fine aggregate particle size and morphology on the early strengths of SCC" in 16th International Congress of Association of Structural Engineers of Serbia : Proceedings (2022):422-429,
https://hdl.handle.net/21.15107/rcub_vinar_12134 .

Properties of heavyweight SCC with fly ash

Janković, Ksenija; Stojanović, Marko; Bojović, Dragan; Terzić, Anja; Stanković, Srboljub

(2022)

TY  - CONF
AU  - Janković, Ksenija
AU  - Stojanović, Marko
AU  - Bojović, Dragan
AU  - Terzić, Anja
AU  - Stanković, Srboljub
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12135
C3  - XXVIII Congress DIMK and IX Congress SIGP with International Symposium on Researching and Application of Contemporary Achievements in Civil Engineering in the Field of Materials and Structures : Proceedings
T1  - Properties of heavyweight SCC with fly ash
T1  - Svojstva teškog SCC sa letećim pepelom
SP  - 389
EP  - 396
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12135
ER  - 
@conference{
author = "Janković, Ksenija and Stojanović, Marko and Bojović, Dragan and Terzić, Anja and Stanković, Srboljub",
year = "2022",
journal = "XXVIII Congress DIMK and IX Congress SIGP with International Symposium on Researching and Application of Contemporary Achievements in Civil Engineering in the Field of Materials and Structures : Proceedings",
title = "Properties of heavyweight SCC with fly ash, Svojstva teškog SCC sa letećim pepelom",
pages = "389-396",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12135"
}
Janković, K., Stojanović, M., Bojović, D., Terzić, A.,& Stanković, S.. (2022). Properties of heavyweight SCC with fly ash. in XXVIII Congress DIMK and IX Congress SIGP with International Symposium on Researching and Application of Contemporary Achievements in Civil Engineering in the Field of Materials and Structures : Proceedings, 389-396.
https://hdl.handle.net/21.15107/rcub_vinar_12135
Janković K, Stojanović M, Bojović D, Terzić A, Stanković S. Properties of heavyweight SCC with fly ash. in XXVIII Congress DIMK and IX Congress SIGP with International Symposium on Researching and Application of Contemporary Achievements in Civil Engineering in the Field of Materials and Structures : Proceedings. 2022;:389-396.
https://hdl.handle.net/21.15107/rcub_vinar_12135 .
Janković, Ksenija, Stojanović, Marko, Bojović, Dragan, Terzić, Anja, Stanković, Srboljub, "Properties of heavyweight SCC with fly ash" in XXVIII Congress DIMK and IX Congress SIGP with International Symposium on Researching and Application of Contemporary Achievements in Civil Engineering in the Field of Materials and Structures : Proceedings (2022):389-396,
https://hdl.handle.net/21.15107/rcub_vinar_12135 .

Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima

Grahovac, Nebojša; Stanković, Srboljub

(2022)

TY  - PAT
AU  - Grahovac, Nebojša
AU  - Stanković, Srboljub
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12127
AB  - Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima se sastoji iz sledećih faza: faza (1), matematička simulacija rada uređaja u celini i komponenti uređaja; faza (1.1), razmatranje karakteristika pojedinih komponenti uređaja za određene radne uslove; faza (1.2), dobijanje radnih karakteristika uređaja u celini i faza (2), eksperimentalna analiza ponašanja uređaja pri promenljivim opterećenjima. Osnov
AB  - Method of analyzing the behavior of a refrigeration device under variable loads consists of step (1) of mathematical simulation of device operation process as a whole and device components; step (1.1) of consideration of the characteristics of individual components of the device for certain operating conditions; step (1.2) to obtaining the operating features of the device and step (2) of experimental analysis of device behavior under variable loads. The novelty of the invention is implementation of steps (1, 1.1,1.2).
T2  - Zavod za intelektualnu svojinu Republike Srbije
T1  - Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima
T1  - Method of analyzing the behavior of a refrigeration device under variable loads
IS  - 6
SP  - 13
EP  - 13
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12127
ER  - 
@misc{
author = "Grahovac, Nebojša and Stanković, Srboljub",
year = "2022",
abstract = "Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima se sastoji iz sledećih faza: faza (1), matematička simulacija rada uređaja u celini i komponenti uređaja; faza (1.1), razmatranje karakteristika pojedinih komponenti uređaja za određene radne uslove; faza (1.2), dobijanje radnih karakteristika uređaja u celini i faza (2), eksperimentalna analiza ponašanja uređaja pri promenljivim opterećenjima. Osnov, Method of analyzing the behavior of a refrigeration device under variable loads consists of step (1) of mathematical simulation of device operation process as a whole and device components; step (1.1) of consideration of the characteristics of individual components of the device for certain operating conditions; step (1.2) to obtaining the operating features of the device and step (2) of experimental analysis of device behavior under variable loads. The novelty of the invention is implementation of steps (1, 1.1,1.2).",
journal = "Zavod za intelektualnu svojinu Republike Srbije",
title = "Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima, Method of analyzing the behavior of a refrigeration device under variable loads",
number = "6",
pages = "13-13",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12127"
}
Grahovac, N.,& Stanković, S.. (2022). Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima. in Zavod za intelektualnu svojinu Republike Srbije(6), 13-13.
https://hdl.handle.net/21.15107/rcub_vinar_12127
Grahovac N, Stanković S. Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima. in Zavod za intelektualnu svojinu Republike Srbije. 2022;(6):13-13.
https://hdl.handle.net/21.15107/rcub_vinar_12127 .
Grahovac, Nebojša, Stanković, Srboljub, "Postupak analize ponašanja rashladnog uređaja pri promenljivim opterećenjima" in Zavod za intelektualnu svojinu Republike Srbije, no. 6 (2022):13-13,
https://hdl.handle.net/21.15107/rcub_vinar_12127 .

Postupak optimizacije rashladnog kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatnih jedinica

Grahovac, Nebojša; Stanković, Srboljub

(2022)

TY  - PAT
AU  - Grahovac, Nebojša
AU  - Stanković, Srboljub
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12126
AB  - Postupak optimizacije rada rashladnih kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatiranih jedinica, se sastoji iz tri faze:matematička simulacija rada kompresora, uticaj ugrađenog elektromotora kompresora na rad kompresora i uticaj geometrijskih karakteristika ventila na rad kompresora. Novina pronalaska je u primeni druge i treće faze postupka. Iz postupka proističe da je neophodno ventile konstruktivno prilagođavati odgovarajućim elektromotorima tj. režimima rada rashladnih agregata.
AB  - The method for optimizing the operation of refrigeration compressors by simulating the operation of electric compressor motor and compressor valves within the operation of aggregate units, consists of three phases: mathematical simulation of compressor operation, the influence of the built-in electric motor of the compressor on the operation of the compressor and the influence of the geometric characteristics of the valve on the operation of the compressor. The novelty of the invention is implementation of the second and third phases of the method. It is necessary to constructively adopt the valves to correspond to the electric motor, ie. operating modes of refrigeration units.
T2  - Zavod za intelektualnu svojinu Republike Srbije
T1  - Postupak optimizacije rashladnog kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatnih jedinica
T1  - The method for optimizing refrigeration compressor by simulating the operation of compressor electric motor and compressor valves as part of the aggregate units operation
IS  - 6
SP  - 13
EP  - 13
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12126
ER  - 
@misc{
author = "Grahovac, Nebojša and Stanković, Srboljub",
year = "2022",
abstract = "Postupak optimizacije rada rashladnih kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatiranih jedinica, se sastoji iz tri faze:matematička simulacija rada kompresora, uticaj ugrađenog elektromotora kompresora na rad kompresora i uticaj geometrijskih karakteristika ventila na rad kompresora. Novina pronalaska je u primeni druge i treće faze postupka. Iz postupka proističe da je neophodno ventile konstruktivno prilagođavati odgovarajućim elektromotorima tj. režimima rada rashladnih agregata., The method for optimizing the operation of refrigeration compressors by simulating the operation of electric compressor motor and compressor valves within the operation of aggregate units, consists of three phases: mathematical simulation of compressor operation, the influence of the built-in electric motor of the compressor on the operation of the compressor and the influence of the geometric characteristics of the valve on the operation of the compressor. The novelty of the invention is implementation of the second and third phases of the method. It is necessary to constructively adopt the valves to correspond to the electric motor, ie. operating modes of refrigeration units.",
journal = "Zavod za intelektualnu svojinu Republike Srbije",
title = "Postupak optimizacije rashladnog kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatnih jedinica, The method for optimizing refrigeration compressor by simulating the operation of compressor electric motor and compressor valves as part of the aggregate units operation",
number = "6",
pages = "13-13",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12126"
}
Grahovac, N.,& Stanković, S.. (2022). Postupak optimizacije rashladnog kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatnih jedinica. in Zavod za intelektualnu svojinu Republike Srbije(6), 13-13.
https://hdl.handle.net/21.15107/rcub_vinar_12126
Grahovac N, Stanković S. Postupak optimizacije rashladnog kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatnih jedinica. in Zavod za intelektualnu svojinu Republike Srbije. 2022;(6):13-13.
https://hdl.handle.net/21.15107/rcub_vinar_12126 .
Grahovac, Nebojša, Stanković, Srboljub, "Postupak optimizacije rashladnog kompresora pomoću simulacije rada elektromotora kompresora i ventila kompresora u sklopu rada agregatnih jedinica" in Zavod za intelektualnu svojinu Republike Srbije, no. 6 (2022):13-13,
https://hdl.handle.net/21.15107/rcub_vinar_12126 .

Direct Conversion Of Ionizing Radiation Into Electrical Energy Using PIN Diodes

Carvajal, Miguel; Sarajlić, Milija; Stanković, Srboljub; Vasiljević-Radović, Dana; Ristić, Goran

(2022)

TY  - CONF
AU  - Carvajal, Miguel
AU  - Sarajlić, Milija
AU  - Stanković, Srboljub
AU  - Vasiljević-Radović, Dana
AU  - Ristić, Goran
PY  - 2022
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12121
AB  - The energy that comes from the source of ionizing radiation is enormous and quite
unused. Using energy from ionizing radiation is a novel concept, while so far in the
literature (to the best of our knowledge), only beta radiation has been treated as a
possible source of energy (Quenon 2021). This paper focuses on utilizing gamma
radiation energy using the Cobalt-60 radiation source. Direct conversion of radiation into electrical energy is possible using pn or pin junction-based semiconductor
structures. When high-energy photons hit a semiconductor structure, a built-in
electric field of pn junction can separate the generated electron-hole pairs before
they recombine, creating the potential difference at the component electrodes. The
PIN diodes used in this paper were made in planar technology, with three different
active area surfaces: 0.8, 5 and 80 mm2
, at the Center of Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy, University of Belgrade,
Serbia. The experiment was conducted in controlled laboratory conditions at the
Department of Radiation and Environmental Protection at the Vinča Institute of
Nuclear Sciences, Belgrade, Serbia. The range of gamma radiation dose rates for
which the PIN diodes have been tested is from 1 µGy/h to 10 Gy/h under controlled
conditions at room temperature. It is necessary for the diode to operate in a photovoltaic mode to act as a current source in an electrical circuit. Therefore, during irradiation, the characteristics of diodes: short-circuit current and open-circuit voltage
were measured as the most important parameters of the current source. The lowest
detected dose rate value of the PIN diode with the largest active area (80 mm2
) was
5 mGy/h, while diodes with middle (5 mm2
) and the smallest active area (0.8 mm2
)
were 100 mGy/h. The short-circuit current values of PIN diodes for all active area dimensions have a linear dependence with a given dose rate range. By calculating the
short-circuit current density, we obtain that diodes with different active areas have
almost the same dependence on the dose rate. This result indicates that the current
generated under the ionizing radiation directly depends on the size of the active
region of the PIN diode. On the other hand, open-circuit voltage values do not have
a linear dependence on the dose rate, even the diode with the smallest active area
(0.8 mm2
) has higher values than the diode with the middle active area (5 mm2
).
For the highest dose rate (10 Gy/h), the short-circuit current value of the PIN diode
with the largest active area is 37 nA, and the open-circuit voltage is 118 mV, which
can enable power supply of the low power electric circuits by connecting diodes in
series and parallel. The research should continue in order to develop a self-powered
circuit that will monitor radioactive sources and their environment.
C3  - BPU11 : 11th International Conference of the Balkan Physical Union
T1  - Direct Conversion Of Ionizing Radiation Into Electrical Energy Using PIN Diodes
VL  - 427
SP  - 213
EP  - 214
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12121
ER  - 
@conference{
author = "Carvajal, Miguel and Sarajlić, Milija and Stanković, Srboljub and Vasiljević-Radović, Dana and Ristić, Goran",
year = "2022",
abstract = "The energy that comes from the source of ionizing radiation is enormous and quite
unused. Using energy from ionizing radiation is a novel concept, while so far in the
literature (to the best of our knowledge), only beta radiation has been treated as a
possible source of energy (Quenon 2021). This paper focuses on utilizing gamma
radiation energy using the Cobalt-60 radiation source. Direct conversion of radiation into electrical energy is possible using pn or pin junction-based semiconductor
structures. When high-energy photons hit a semiconductor structure, a built-in
electric field of pn junction can separate the generated electron-hole pairs before
they recombine, creating the potential difference at the component electrodes. The
PIN diodes used in this paper were made in planar technology, with three different
active area surfaces: 0.8, 5 and 80 mm2
, at the Center of Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy, University of Belgrade,
Serbia. The experiment was conducted in controlled laboratory conditions at the
Department of Radiation and Environmental Protection at the Vinča Institute of
Nuclear Sciences, Belgrade, Serbia. The range of gamma radiation dose rates for
which the PIN diodes have been tested is from 1 µGy/h to 10 Gy/h under controlled
conditions at room temperature. It is necessary for the diode to operate in a photovoltaic mode to act as a current source in an electrical circuit. Therefore, during irradiation, the characteristics of diodes: short-circuit current and open-circuit voltage
were measured as the most important parameters of the current source. The lowest
detected dose rate value of the PIN diode with the largest active area (80 mm2
) was
5 mGy/h, while diodes with middle (5 mm2
) and the smallest active area (0.8 mm2
)
were 100 mGy/h. The short-circuit current values of PIN diodes for all active area dimensions have a linear dependence with a given dose rate range. By calculating the
short-circuit current density, we obtain that diodes with different active areas have
almost the same dependence on the dose rate. This result indicates that the current
generated under the ionizing radiation directly depends on the size of the active
region of the PIN diode. On the other hand, open-circuit voltage values do not have
a linear dependence on the dose rate, even the diode with the smallest active area
(0.8 mm2
) has higher values than the diode with the middle active area (5 mm2
).
For the highest dose rate (10 Gy/h), the short-circuit current value of the PIN diode
with the largest active area is 37 nA, and the open-circuit voltage is 118 mV, which
can enable power supply of the low power electric circuits by connecting diodes in
series and parallel. The research should continue in order to develop a self-powered
circuit that will monitor radioactive sources and their environment.",
journal = "BPU11 : 11th International Conference of the Balkan Physical Union",
title = "Direct Conversion Of Ionizing Radiation Into Electrical Energy Using PIN Diodes",
volume = "427",
pages = "213-214",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12121"
}
Carvajal, M., Sarajlić, M., Stanković, S., Vasiljević-Radović, D.,& Ristić, G.. (2022). Direct Conversion Of Ionizing Radiation Into Electrical Energy Using PIN Diodes. in BPU11 : 11th International Conference of the Balkan Physical Union, 427, 213-214.
https://hdl.handle.net/21.15107/rcub_vinar_12121
Carvajal M, Sarajlić M, Stanković S, Vasiljević-Radović D, Ristić G. Direct Conversion Of Ionizing Radiation Into Electrical Energy Using PIN Diodes. in BPU11 : 11th International Conference of the Balkan Physical Union. 2022;427:213-214.
https://hdl.handle.net/21.15107/rcub_vinar_12121 .
Carvajal, Miguel, Sarajlić, Milija, Stanković, Srboljub, Vasiljević-Radović, Dana, Ristić, Goran, "Direct Conversion Of Ionizing Radiation Into Electrical Energy Using PIN Diodes" in BPU11 : 11th International Conference of the Balkan Physical Union, 427 (2022):213-214,