Numerous cases of radiation-induced tissue reactions following interventional cardiology (IC) procedures have been reported, resulting in the need for an optimized and personalized dosimetry. At present, there are many fluoroscopy units without Digital Imaging and Communications in Medicine (DICOM) Radiation Dose Structured Report globally installed. Many of these have not been updated yet, and may never be, therefore, the main objectives of this paper are to develop an offline skin dose mapping application, which uses DICOM headers for the peak skin dose (PSD) assessment and to compare the PSD assessment results to XR-RV3 Gafchromic film for common IC procedures. The mean deviation between the measured and the calculated PSD was 8.7 ± 26.3%. Simulated skin dose map showed good matching with XR-RV3 Gafchromic film. The skin dose mapping application presented in this paper is an elegant solution and a suitable alternative to XR-RV3 Gafchromic film.
Извор:
Radiation Protection Dosimetry, 2020, 188, 4, 508-515Финансирање / пројекти:
- Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)
DOI: 10.1093/rpd/ncaa002
ISSN: 0144-8420
PubMed: 32614065
WoS: 000579669700012
Scopus: 2-s2.0-85087471282
Институција/група
VinčaTY - JOUR AU - Krajinović, Marko AU - Dobrić, Milan R. AU - Ciraj-Bjelac, Olivera PY - 2020 UR - https://vinar.vin.bg.ac.rs/handle/123456789/9066 AB - Numerous cases of radiation-induced tissue reactions following interventional cardiology (IC) procedures have been reported, resulting in the need for an optimized and personalized dosimetry. At present, there are many fluoroscopy units without Digital Imaging and Communications in Medicine (DICOM) Radiation Dose Structured Report globally installed. Many of these have not been updated yet, and may never be, therefore, the main objectives of this paper are to develop an offline skin dose mapping application, which uses DICOM headers for the peak skin dose (PSD) assessment and to compare the PSD assessment results to XR-RV3 Gafchromic film for common IC procedures. The mean deviation between the measured and the calculated PSD was 8.7 ± 26.3%. Simulated skin dose map showed good matching with XR-RV3 Gafchromic film. The skin dose mapping application presented in this paper is an elegant solution and a suitable alternative to XR-RV3 Gafchromic film. T2 - Radiation Protection Dosimetry T1 - Skin dose mapping in interventional cardiology: a practical solution VL - 188 IS - 4 SP - 508 EP - 515 DO - 10.1093/rpd/ncaa002 ER -
@article{ author = "Krajinović, Marko and Dobrić, Milan R. and Ciraj-Bjelac, Olivera", year = "2020", abstract = "Numerous cases of radiation-induced tissue reactions following interventional cardiology (IC) procedures have been reported, resulting in the need for an optimized and personalized dosimetry. At present, there are many fluoroscopy units without Digital Imaging and Communications in Medicine (DICOM) Radiation Dose Structured Report globally installed. Many of these have not been updated yet, and may never be, therefore, the main objectives of this paper are to develop an offline skin dose mapping application, which uses DICOM headers for the peak skin dose (PSD) assessment and to compare the PSD assessment results to XR-RV3 Gafchromic film for common IC procedures. The mean deviation between the measured and the calculated PSD was 8.7 ± 26.3%. Simulated skin dose map showed good matching with XR-RV3 Gafchromic film. The skin dose mapping application presented in this paper is an elegant solution and a suitable alternative to XR-RV3 Gafchromic film.", journal = "Radiation Protection Dosimetry", title = "Skin dose mapping in interventional cardiology: a practical solution", volume = "188", number = "4", pages = "508-515", doi = "10.1093/rpd/ncaa002" }
Krajinović, M., Dobrić, M. R.,& Ciraj-Bjelac, O.. (2020). Skin dose mapping in interventional cardiology: a practical solution. in Radiation Protection Dosimetry, 188(4), 508-515. https://doi.org/10.1093/rpd/ncaa002
Krajinović M, Dobrić MR, Ciraj-Bjelac O. Skin dose mapping in interventional cardiology: a practical solution. in Radiation Protection Dosimetry. 2020;188(4):508-515. doi:10.1093/rpd/ncaa002 .
Krajinović, Marko, Dobrić, Milan R., Ciraj-Bjelac, Olivera, "Skin dose mapping in interventional cardiology: a practical solution" in Radiation Protection Dosimetry, 188, no. 4 (2020):508-515, https://doi.org/10.1093/rpd/ncaa002 . .