Претраживање
Приказ резултата 21-30 од 35
Optimization of Sr-ion extraction from the contaminated soil using Box-Benken design
(RAD Centre, Niš, Serbia, 2019)
Among the factors that affect the degradation of soil quality, contamination with radioactive substances has gained significance due to the fast development and exploitation of nuclear energy. The remediation measures based ...
Build-Up PMMA Plate Effect on Calibration of TLD Reader
(RAD Conference Proceedings, 2015)
The routine monitoring of the occupationally exposed individuals constitutes an integral part of radiation protection program implemented at the Vinca Institute of Nuclear Sciences (INNV). The Individual monitoring service ...
Radionuclide Content in Laundry Detergents Commercially Available on the Serbian Market and Assessment of Radiological Environmental Hazards
(Nuclear technology and radiation protection, 2017)
Laundry detergents are chemicals widely used in everyday life, and in numerous industry branches. In order to perceive the radiological aspect of environmental pollution by wastewater, the analysis of laundry detergents ...
A European survey on the regulatory status for the estimation of the effective dose and the equivalent dose to the lens of the eye when radiation protection garments are used
(Journal of Radiological Protection, 2019)
Following the proposal of the ICRP for the reduction of the dose limit for the lens of the eye, which has been adopted by the International Atomic Energy Agency and the European Council, concerns have been raised about the ...
Scale Transformations in Phase Space and Stretched States of a Harmonic Oscillator
(Theoretical and Mathematical Physics, 2017)
We consider scale transformations (q, p) - GT (lambda q, lambda p) in phase space. They induce transformations of the Husimi functions H(q, p) defined in this space. We consider the Husimi functions for states that are ...
Use of Husimi function in time frequency signal analysis / Primena Husimijeve funkcije u vremensko-frekvencijskoj analizi signala
(Tehnika, 2013)
Husimi function originated in phase space formulation of quantum mechanics. This function appears naturally whenever simultaneous measurement of coordinate and impulse with maximal accuracy allowed by the Heisenberg ...
Husimi function for time-frequency analysis in optical, microwave and plasmonics aplications
(Belgrade : Institute of Physics Belgrade, 2017)
Many real-world signals, occurring in everyday engineering practice are non-stationary, and as a result, their frequency components may change gradually or abruptly over time. Such signals are typically analyzed using ...
Trajectory based interpretation of the laser light diffraction on a sharp edge
(Belgrade : Institute of Physics Belgrade, 2017)
Bohmian mechanics enables visualization and interpretation of quantum mechanical behavior of massive particles through trajectories connected to the probability current density [1]. Electromagnetic field also admits ...
Occupational Eye Lens Dose Estimated Using Whole-Body Dosemeter In Interventional Cardiology And Radiology: A Monte Carlo Study
(Radiation Protection Dosimetry, 2019)
Medical personnel performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. Reduction of the eye lens dose limit made its assessment ...
Utilizing Monte Carlo simulations in estimation of occupational eye lens dose based on whole body dosemeter in interventional cardiology and radiology
(Nuclear Technology and Radiation Protection, 2018)
Medical staff performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. With new epidemiological evidences and recently reduced ...