Time-integrated luminescence thermometry of Eu3+ and Dy3+ doped YVO4
Authorized Users Only
2019
Article (Published version)
,
© 2019 Elsevier B.V.
Metadata
Show full item recordAbstract
Photoluminescence spectra of bulk YVO4 doped with 1 mol% of Eu3+ and Dy3+ were recorded on the range from room temperature to 733 K, in 20 K steps. The temperature sensing performances were estimated by the luminescence intensity ratio, line-broadening and line-shift methods. The luminescence intensity ratio was tested by the ratio of intensities of 5D1→7F1 and 5D0→7F2,4 transitions of Eu3+, and 4I15/2→6H15/2 and 4F9/2→6H15/2 transitions of Dy3+. The temperature dependent line-broadenings were measured on 5D0→7F2 and 4F9/2→6H13/2 of Eu3+ and Dy3+, respectively. The line-shifts were investigated on 5D0→7F1 and 4F9/2→6H15/2 of Eu3+ and Dy3+, respectively. The experimental data of all three methods is fitted and is in excellent agreement with the theory. The calculated thermometric figures of merit, absolute and relative sensitivities, show the sensor performances at the given temperature, and allow the selection of the best sensor material or transition to be chosen for the desired tempe...rature range. © 2019 Elsevier B.V.
Keywords:
YVO4Eu3+ / YVO4Dy3+ / Thermographic phosphor / Line-broadening / Line-shift / Luminescence intensity ratioSource:
Sensors and Actuators A: Physical, 2019, 295, 450-455Funding / projects:
- Graphitic and Inorganic Low-dimensional Nanostructures (RS-MESTD-Basic Research (BR or ON)-171035)
- Materials of Reduced Dimensions for Efficient Light Harvesting and Energy conversion (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-45020)
DOI: 10.1016/j.sna.2019.06.035
ISSN: 0924-4247
WoS: 000483635900051
Scopus: 2-s2.0-85067626148
URI
https://linkinghub.elsevier.com/retrieve/pii/S0924424719307046https://vinar.vin.bg.ac.rs/handle/123456789/8356
Collections
Institution/Community
VinčaTY - JOUR AU - Ćirić, Aleksandar AU - Stojadinović, Stevan AU - Dramićanin, Miroslav PY - 2019 UR - https://linkinghub.elsevier.com/retrieve/pii/S0924424719307046 UR - https://vinar.vin.bg.ac.rs/handle/123456789/8356 AB - Photoluminescence spectra of bulk YVO4 doped with 1 mol% of Eu3+ and Dy3+ were recorded on the range from room temperature to 733 K, in 20 K steps. The temperature sensing performances were estimated by the luminescence intensity ratio, line-broadening and line-shift methods. The luminescence intensity ratio was tested by the ratio of intensities of 5D1→7F1 and 5D0→7F2,4 transitions of Eu3+, and 4I15/2→6H15/2 and 4F9/2→6H15/2 transitions of Dy3+. The temperature dependent line-broadenings were measured on 5D0→7F2 and 4F9/2→6H13/2 of Eu3+ and Dy3+, respectively. The line-shifts were investigated on 5D0→7F1 and 4F9/2→6H15/2 of Eu3+ and Dy3+, respectively. The experimental data of all three methods is fitted and is in excellent agreement with the theory. The calculated thermometric figures of merit, absolute and relative sensitivities, show the sensor performances at the given temperature, and allow the selection of the best sensor material or transition to be chosen for the desired temperature range. © 2019 Elsevier B.V. T2 - Sensors and Actuators A: Physical T1 - Time-integrated luminescence thermometry of Eu3+ and Dy3+ doped YVO4 VL - 295 SP - 450 EP - 455 DO - 10.1016/j.sna.2019.06.035 ER -
@article{ author = "Ćirić, Aleksandar and Stojadinović, Stevan and Dramićanin, Miroslav", year = "2019", abstract = "Photoluminescence spectra of bulk YVO4 doped with 1 mol% of Eu3+ and Dy3+ were recorded on the range from room temperature to 733 K, in 20 K steps. The temperature sensing performances were estimated by the luminescence intensity ratio, line-broadening and line-shift methods. The luminescence intensity ratio was tested by the ratio of intensities of 5D1→7F1 and 5D0→7F2,4 transitions of Eu3+, and 4I15/2→6H15/2 and 4F9/2→6H15/2 transitions of Dy3+. The temperature dependent line-broadenings were measured on 5D0→7F2 and 4F9/2→6H13/2 of Eu3+ and Dy3+, respectively. The line-shifts were investigated on 5D0→7F1 and 4F9/2→6H15/2 of Eu3+ and Dy3+, respectively. The experimental data of all three methods is fitted and is in excellent agreement with the theory. The calculated thermometric figures of merit, absolute and relative sensitivities, show the sensor performances at the given temperature, and allow the selection of the best sensor material or transition to be chosen for the desired temperature range. © 2019 Elsevier B.V.", journal = "Sensors and Actuators A: Physical", title = "Time-integrated luminescence thermometry of Eu3+ and Dy3+ doped YVO4", volume = "295", pages = "450-455", doi = "10.1016/j.sna.2019.06.035" }
Ćirić, A., Stojadinović, S.,& Dramićanin, M.. (2019). Time-integrated luminescence thermometry of Eu3+ and Dy3+ doped YVO4. in Sensors and Actuators A: Physical, 295, 450-455. https://doi.org/10.1016/j.sna.2019.06.035
Ćirić A, Stojadinović S, Dramićanin M. Time-integrated luminescence thermometry of Eu3+ and Dy3+ doped YVO4. in Sensors and Actuators A: Physical. 2019;295:450-455. doi:10.1016/j.sna.2019.06.035 .
Ćirić, Aleksandar, Stojadinović, Stevan, Dramićanin, Miroslav, "Time-integrated luminescence thermometry of Eu3+ and Dy3+ doped YVO4" in Sensors and Actuators A: Physical, 295 (2019):450-455, https://doi.org/10.1016/j.sna.2019.06.035 . .