A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone
Само за регистроване кориснике
2018
Аутори
Ognjanović, MilošStanković, Dalibor M.
Fabian, Martin
Vukadinović, Aleksandar
Prijović, Željko
Dojčinović, Biljana P.
Antić, Bratislav
Чланак у часопису (Објављена верзија)
,
© 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
Метаподаци
Приказ свих података о документуАпстракт
In this work facile one step synthesis of magnesium ferrite (MgFe2O4) nanoparticles decorated on reduced graphene oxide (MgFe@RGO) using a microwave assisted hydrothermal procedure is reported. The synthesized material was characterized with help of several techniques and applied for the modification of glassy carbon electrode. Such prepared electrode was utilized for successive simultaneous detection of structurally similar compounds, 1,2- and 1,4-dihydroxibenzenes (catechol (CC) and hydroquinone (HQ)), using differential pulse voltammetry technique. It was found that oxidation current increases linearly with the concentrations of both investigated compounds. Detection limits for both species are ≤0.31 μM. The best analytical response in the presence of both CC and HQ, taking into account peak shape and peak current, was obtained at pH 5.6 utilizing acetate buffer solution. The often-presented species in the surface waters as well as gallic acid and caffeine do not interfere with dete...rmination of CC and HQ, while ascorbic acid shows high interference. The method is successfully applied for detection of catechol and hydroquinone in real samples analyses. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
Кључне речи:
MgFe@RGO nanocomposite / Magnesium ferrite / Dihydroxibenzenes / Differential pulse voltammetryИзвор:
Electroanalysis, 2018, 30, 11, 2620-2627Финансирање / пројекти:
- Ministry of Education, Science and Technological Development of the Republic of Serbia [E!9982]
- Strengthening of the MagBioVin Research and Innovation Team for Development of Novel Approaches for Tumour Therapy based on Nanostructured Materials (EU-FP7-621375)
DOI: 10.1002/elan.201800357
ISSN: 1040-0397; 1521-4109
WoS: 000450148200013
Scopus: 2-s2.0-85052920134
Колекције
Институција/група
VinčaTY - JOUR AU - Ognjanović, Miloš AU - Stanković, Dalibor M. AU - Fabian, Martin AU - Vukadinović, Aleksandar AU - Prijović, Željko AU - Dojčinović, Biljana P. AU - Antić, Bratislav PY - 2018 UR - http://doi.wiley.com/10.1002/elan.201800357 UR - https://vinar.vin.bg.ac.rs/handle/123456789/7961 AB - In this work facile one step synthesis of magnesium ferrite (MgFe2O4) nanoparticles decorated on reduced graphene oxide (MgFe@RGO) using a microwave assisted hydrothermal procedure is reported. The synthesized material was characterized with help of several techniques and applied for the modification of glassy carbon electrode. Such prepared electrode was utilized for successive simultaneous detection of structurally similar compounds, 1,2- and 1,4-dihydroxibenzenes (catechol (CC) and hydroquinone (HQ)), using differential pulse voltammetry technique. It was found that oxidation current increases linearly with the concentrations of both investigated compounds. Detection limits for both species are ≤0.31 μM. The best analytical response in the presence of both CC and HQ, taking into account peak shape and peak current, was obtained at pH 5.6 utilizing acetate buffer solution. The often-presented species in the surface waters as well as gallic acid and caffeine do not interfere with determination of CC and HQ, while ascorbic acid shows high interference. The method is successfully applied for detection of catechol and hydroquinone in real samples analyses. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim T2 - Electroanalysis T1 - A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone VL - 30 IS - 11 SP - 2620 EP - 2627 DO - 10.1002/elan.201800357 ER -
@article{ author = "Ognjanović, Miloš and Stanković, Dalibor M. and Fabian, Martin and Vukadinović, Aleksandar and Prijović, Željko and Dojčinović, Biljana P. and Antić, Bratislav", year = "2018", abstract = "In this work facile one step synthesis of magnesium ferrite (MgFe2O4) nanoparticles decorated on reduced graphene oxide (MgFe@RGO) using a microwave assisted hydrothermal procedure is reported. The synthesized material was characterized with help of several techniques and applied for the modification of glassy carbon electrode. Such prepared electrode was utilized for successive simultaneous detection of structurally similar compounds, 1,2- and 1,4-dihydroxibenzenes (catechol (CC) and hydroquinone (HQ)), using differential pulse voltammetry technique. It was found that oxidation current increases linearly with the concentrations of both investigated compounds. Detection limits for both species are ≤0.31 μM. The best analytical response in the presence of both CC and HQ, taking into account peak shape and peak current, was obtained at pH 5.6 utilizing acetate buffer solution. The often-presented species in the surface waters as well as gallic acid and caffeine do not interfere with determination of CC and HQ, while ascorbic acid shows high interference. The method is successfully applied for detection of catechol and hydroquinone in real samples analyses. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim", journal = "Electroanalysis", title = "A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone", volume = "30", number = "11", pages = "2620-2627", doi = "10.1002/elan.201800357" }
Ognjanović, M., Stanković, D. M., Fabian, M., Vukadinović, A., Prijović, Ž., Dojčinović, B. P.,& Antić, B.. (2018). A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone. in Electroanalysis, 30(11), 2620-2627. https://doi.org/10.1002/elan.201800357
Ognjanović M, Stanković DM, Fabian M, Vukadinović A, Prijović Ž, Dojčinović BP, Antić B. A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone. in Electroanalysis. 2018;30(11):2620-2627. doi:10.1002/elan.201800357 .
Ognjanović, Miloš, Stanković, Dalibor M., Fabian, Martin, Vukadinović, Aleksandar, Prijović, Željko, Dojčinović, Biljana P., Antić, Bratislav, "A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone" in Electroanalysis, 30, no. 11 (2018):2620-2627, https://doi.org/10.1002/elan.201800357 . .