Monitoring of respiratory volumes by an long period grating sensor of bending
Apstrakt
Here, we present a method of respiratory volumes monitoring using a single fiber-grating sensor of bending. Measurements are conducted using simple monochromatic interrogation scheme that relies on a photodiode measurement of the power transmitted through a long period grating (LPG) sensor at fixed wavelength. Good sensor accuracy in measurements of tidal and minute respiratory volumes for different types of breathing is achieved.
Izvor:
Journal of Physics: Conference Series, 2016, 682Finansiranje / projekti:
- Fotonika mikro i nano strukturnih materijala (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-45010)
Napomena:
- Conference on Light in Nanoscience and Nanotechnology (LNN), Oct 20-22, 2015, Hissar, Bulgaria
DOI: 10.1088/1742-6596/682/1/012008
ISSN: 1742-6588
WoS: 000372173400008
Scopus: 2-s2.0-84964671775
Kolekcije
Institucija/grupa
VinčaTY - CONF AU - Raičević, Nevena AU - Ivanović, Marija D. AU - Beličev, Petar AU - Petrović, Jovana S. PY - 2016 UR - https://vinar.vin.bg.ac.rs/handle/123456789/7099 AB - Here, we present a method of respiratory volumes monitoring using a single fiber-grating sensor of bending. Measurements are conducted using simple monochromatic interrogation scheme that relies on a photodiode measurement of the power transmitted through a long period grating (LPG) sensor at fixed wavelength. Good sensor accuracy in measurements of tidal and minute respiratory volumes for different types of breathing is achieved. C3 - Journal of Physics: Conference Series T1 - Monitoring of respiratory volumes by an long period grating sensor of bending VL - 682 DO - 10.1088/1742-6596/682/1/012008 ER -
@conference{ author = "Raičević, Nevena and Ivanović, Marija D. and Beličev, Petar and Petrović, Jovana S.", year = "2016", abstract = "Here, we present a method of respiratory volumes monitoring using a single fiber-grating sensor of bending. Measurements are conducted using simple monochromatic interrogation scheme that relies on a photodiode measurement of the power transmitted through a long period grating (LPG) sensor at fixed wavelength. Good sensor accuracy in measurements of tidal and minute respiratory volumes for different types of breathing is achieved.", journal = "Journal of Physics: Conference Series", title = "Monitoring of respiratory volumes by an long period grating sensor of bending", volume = "682", doi = "10.1088/1742-6596/682/1/012008" }
Raičević, N., Ivanović, M. D., Beličev, P.,& Petrović, J. S.. (2016). Monitoring of respiratory volumes by an long period grating sensor of bending. in Journal of Physics: Conference Series, 682. https://doi.org/10.1088/1742-6596/682/1/012008
Raičević N, Ivanović MD, Beličev P, Petrović JS. Monitoring of respiratory volumes by an long period grating sensor of bending. in Journal of Physics: Conference Series. 2016;682. doi:10.1088/1742-6596/682/1/012008 .
Raičević, Nevena, Ivanović, Marija D., Beličev, Petar, Petrović, Jovana S., "Monitoring of respiratory volumes by an long period grating sensor of bending" in Journal of Physics: Conference Series, 682 (2016), https://doi.org/10.1088/1742-6596/682/1/012008 . .