Investigation of the cigar burner combustion system for baled biomass
Само за регистроване кориснике
2013
Аутори
Repić, BranislavDakić, Dragoljub V.
Erić, Aleksandar
Đurović, Dejan M.
Marinković, Ana D.
Nemoda, Stevan
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
Biomass is deemed to be the main source of renewable energy in Serbia. Over the past couple of years, considerable efforts have been made to develop a technology which would enable biomass bales of various sizes and shapes to be used for energy production. A hot water boiler with cigarette type of combustion was constructed and used in the experimental investigation of biomass combustion phenomena. During the experiments performed, numerous parameters were measured: flue gas temperature, water temperature at the boiler inlet and outlet, while O-2, CO2, CO, SO2, and NOx content in the flue gas was measured at the boiler outlet. Experiments were performed with biomass feed rate of 0.12 kg/s, mean boiler output of 1.56 MW and mean excess air coefficient of 2.1. During the steady state boiler operation, exhaust gas temperature was measured to be around 150-160 degrees C and obtained CO and NOx emission rates were found to be quite acceptable. In addition, combustion of biomass bales in cig...ar burners was modelled by the means of appropriate numerical simulation. A good agreement between experimental and numerical results was obtained. (C) 2013 Elsevier Ltd. All rights reserved.
Кључне речи:
Biomass / Combustion / Boiler / Straw / Cigar burner / ModellingИзвор:
Biomass and Bioenergy, 2013, 58, 10-19Финансирање / пројекти:
- Развој и унапређење технологија за енергетски ефикасно коришћење више форми пољопривредне и шумске биомасе на еколошки прихватљив начин, уз могућност когенерације (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-42011)
DOI: 10.1016/j.biombioe.2013.10.016
ISSN: 0961-9534; 1873-2909
WoS: 000330490600002
Scopus: 2-s2.0-84888833888
Колекције
Институција/група
VinčaTY - JOUR AU - Repić, Branislav AU - Dakić, Dragoljub V. AU - Erić, Aleksandar AU - Đurović, Dejan M. AU - Marinković, Ana D. AU - Nemoda, Stevan PY - 2013 UR - https://vinar.vin.bg.ac.rs/handle/123456789/5857 AB - Biomass is deemed to be the main source of renewable energy in Serbia. Over the past couple of years, considerable efforts have been made to develop a technology which would enable biomass bales of various sizes and shapes to be used for energy production. A hot water boiler with cigarette type of combustion was constructed and used in the experimental investigation of biomass combustion phenomena. During the experiments performed, numerous parameters were measured: flue gas temperature, water temperature at the boiler inlet and outlet, while O-2, CO2, CO, SO2, and NOx content in the flue gas was measured at the boiler outlet. Experiments were performed with biomass feed rate of 0.12 kg/s, mean boiler output of 1.56 MW and mean excess air coefficient of 2.1. During the steady state boiler operation, exhaust gas temperature was measured to be around 150-160 degrees C and obtained CO and NOx emission rates were found to be quite acceptable. In addition, combustion of biomass bales in cigar burners was modelled by the means of appropriate numerical simulation. A good agreement between experimental and numerical results was obtained. (C) 2013 Elsevier Ltd. All rights reserved. T2 - Biomass and Bioenergy T1 - Investigation of the cigar burner combustion system for baled biomass VL - 58 SP - 10 EP - 19 DO - 10.1016/j.biombioe.2013.10.016 ER -
@article{ author = "Repić, Branislav and Dakić, Dragoljub V. and Erić, Aleksandar and Đurović, Dejan M. and Marinković, Ana D. and Nemoda, Stevan", year = "2013", abstract = "Biomass is deemed to be the main source of renewable energy in Serbia. Over the past couple of years, considerable efforts have been made to develop a technology which would enable biomass bales of various sizes and shapes to be used for energy production. A hot water boiler with cigarette type of combustion was constructed and used in the experimental investigation of biomass combustion phenomena. During the experiments performed, numerous parameters were measured: flue gas temperature, water temperature at the boiler inlet and outlet, while O-2, CO2, CO, SO2, and NOx content in the flue gas was measured at the boiler outlet. Experiments were performed with biomass feed rate of 0.12 kg/s, mean boiler output of 1.56 MW and mean excess air coefficient of 2.1. During the steady state boiler operation, exhaust gas temperature was measured to be around 150-160 degrees C and obtained CO and NOx emission rates were found to be quite acceptable. In addition, combustion of biomass bales in cigar burners was modelled by the means of appropriate numerical simulation. A good agreement between experimental and numerical results was obtained. (C) 2013 Elsevier Ltd. All rights reserved.", journal = "Biomass and Bioenergy", title = "Investigation of the cigar burner combustion system for baled biomass", volume = "58", pages = "10-19", doi = "10.1016/j.biombioe.2013.10.016" }
Repić, B., Dakić, D. V., Erić, A., Đurović, D. M., Marinković, A. D.,& Nemoda, S.. (2013). Investigation of the cigar burner combustion system for baled biomass. in Biomass and Bioenergy, 58, 10-19. https://doi.org/10.1016/j.biombioe.2013.10.016
Repić B, Dakić DV, Erić A, Đurović DM, Marinković AD, Nemoda S. Investigation of the cigar burner combustion system for baled biomass. in Biomass and Bioenergy. 2013;58:10-19. doi:10.1016/j.biombioe.2013.10.016 .
Repić, Branislav, Dakić, Dragoljub V., Erić, Aleksandar, Đurović, Dejan M., Marinković, Ana D., Nemoda, Stevan, "Investigation of the cigar burner combustion system for baled biomass" in Biomass and Bioenergy, 58 (2013):10-19, https://doi.org/10.1016/j.biombioe.2013.10.016 . .