Приказ основних података о документу

dc.creatorChatrchyan, S.
dc.creatorAdžić, Petar
dc.creatorĐorđević, Miloš
dc.creatorJovanović, Dragana J.
dc.creatorKrpić, D.
dc.creatorMaletić, Dimitrije
dc.creatorPuzović, Jovan M.
dc.creatorSmiljković, Nikola
dc.creatorMilenović, Predrag
dc.date.accessioned2018-03-01T21:19:19Z
dc.date.available2018-03-01T21:19:19Z
dc.date.issued2010
dc.identifier.issn1748-0221
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/4068
dc.description.abstractThe operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented.en
dc.relationFMSR (Austria), FNRS (Belgium), FWO (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN (China), CAS (China), MoST (China), NSFC (China), COLCIEN-CIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences (Estonia), NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain, CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation
dc.rightsopenAccessen
dc.sourceJournal of Instrumentationen
dc.subjectCalorimetersen
dc.subjectLarge detector systems for particle and astroparticle physicsen
dc.titlePerformance and operation of the CMS electromagnetic calorimeteren
dc.typearticleen
dcterms.abstractЂорђевић Милош; Миленовић Предраг; Цхатрцхyан, С.; Aдзиц, П.; Јовановиц, Д.; Крпиц, Д.; Малетиц, Д.; Пузовиц, Ј.; Смиљковиц, Н.;
dc.citation.volume5
dc.identifier.wos000280524100023
dc.identifier.doi10.1088/1748-0221/5/03/T03010
dc.citation.otherArticle Number: T03010
dc.citation.rankM21a
dc.contributor.count(ukupan broj autora: 2424)
dc.identifier.scopus2-s2.0-79953281768
dc.identifier.fulltexthttps://vinar.vin.bg.ac.rs//bitstream/id/12658/4064.pdf


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу