ВинаР - Репозиторијум Института за нуклеарне науке Винча
    • English
    • Српски
    • Српски (Serbia)
  • Српски (ћирилица) 
    • Енглески
    • Српски (ћирилица)
    • Српски (латиница)
  • Пријава
Преглед записа 
  •   ВинаР
  • Vinča
  • Radovi istraživača
  • Преглед записа
  •   ВинаР
  • Vinča
  • Radovi istraživača
  • Преглед записа
JavaScript is disabled for your browser. Some features of this site may not work without it.

S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing

Само за регистроване кориснике
2021
Аутори
Knežević, Sara
Ognjanović, Miloš
Gavrović-Jankulović, Marija
Đurašinović, Tatjana
Antić, Bratislav
Vranješ-Đurić, Sanja
Stanković, Dalibor M.
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
S-Adenosyl-L-Homocysteine (AdoHcy) is a crucial pathological factor in homocysteine-associated disorders. We developed an impedimetric approach for single drop S-Adenosyl-L-Homocysteine detection, based on S-Adenosyl-L-Homocysteine hydrolase (SAH), produced in the prokaryotic expression system (E. coli) by recombinant DNA technology, immobilized on citrate acid-coated gallium oxyhydroxide dispersed over single-walled carbon nanotubes (CA/GaO(OH)@SWCNT). The proposed biosensor offers detection of AdoHcy, with a limit of detection (LOD) of 0.17 μM. with operating linear range from 1 to 44 μM. The remarkable stability of gallium oxyhydroxide crystal was further improved by citric acid coating and its optical, electrical and physical anisotropy was skipped using SWCNTs.
Кључне речи:
AdoHcy / Biosensor / gallium oxyhydroxide / S-Adenosyl-L-Homocysteine hydrolase / SWCNTs
Извор:
Electroanalysis, 2021, 34, 1, 15-24
Финансирање / пројекти:
  • EUREKA [E! 13303 MED-BIO-TEST]

DOI: 10.1002/elan.202100362

ISSN: 1521-4109

WoS: 000704259700001

Scopus: 2-s2.0-85116507413
[ Google Scholar ]
1
1
URI
https://vinar.vin.bg.ac.rs/handle/123456789/9976
Колекције
  • Radovi istraživača
Институција/група
Vinča
TY  - JOUR
AU  - Knežević, Sara
AU  - Ognjanović, Miloš
AU  - Gavrović-Jankulović, Marija
AU  - Đurašinović, Tatjana
AU  - Antić, Bratislav
AU  - Vranješ-Đurić, Sanja
AU  - Stanković, Dalibor M.
PY  - 2021
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9976
AB  - S-Adenosyl-L-Homocysteine (AdoHcy) is a crucial pathological factor in homocysteine-associated disorders. We developed an impedimetric approach for single drop S-Adenosyl-L-Homocysteine detection, based on S-Adenosyl-L-Homocysteine hydrolase (SAH), produced in the prokaryotic expression system (E. coli) by recombinant DNA technology, immobilized on citrate acid-coated gallium oxyhydroxide dispersed over single-walled carbon nanotubes (CA/GaO(OH)@SWCNT). The proposed biosensor offers detection of AdoHcy, with a limit of detection (LOD) of 0.17 μM. with operating linear range from 1 to 44 μM. The remarkable stability of gallium oxyhydroxide crystal was further improved by citric acid coating and its optical, electrical and physical anisotropy was skipped using SWCNTs.
T2  - Electroanalysis
T1  - S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing
VL  - 34
IS  - 1
SP  - 15
EP  - 24
DO  - 10.1002/elan.202100362
ER  - 
@article{
author = "Knežević, Sara and Ognjanović, Miloš and Gavrović-Jankulović, Marija and Đurašinović, Tatjana and Antić, Bratislav and Vranješ-Đurić, Sanja and Stanković, Dalibor M.",
year = "2021",
abstract = "S-Adenosyl-L-Homocysteine (AdoHcy) is a crucial pathological factor in homocysteine-associated disorders. We developed an impedimetric approach for single drop S-Adenosyl-L-Homocysteine detection, based on S-Adenosyl-L-Homocysteine hydrolase (SAH), produced in the prokaryotic expression system (E. coli) by recombinant DNA technology, immobilized on citrate acid-coated gallium oxyhydroxide dispersed over single-walled carbon nanotubes (CA/GaO(OH)@SWCNT). The proposed biosensor offers detection of AdoHcy, with a limit of detection (LOD) of 0.17 μM. with operating linear range from 1 to 44 μM. The remarkable stability of gallium oxyhydroxide crystal was further improved by citric acid coating and its optical, electrical and physical anisotropy was skipped using SWCNTs.",
journal = "Electroanalysis",
title = "S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing",
volume = "34",
number = "1",
pages = "15-24",
doi = "10.1002/elan.202100362"
}
Knežević, S., Ognjanović, M., Gavrović-Jankulović, M., Đurašinović, T., Antić, B., Vranješ-Đurić, S.,& Stanković, D. M.. (2021). S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing. in Electroanalysis, 34(1), 15-24.
https://doi.org/10.1002/elan.202100362
Knežević S, Ognjanović M, Gavrović-Jankulović M, Đurašinović T, Antić B, Vranješ-Đurić S, Stanković DM. S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing. in Electroanalysis. 2021;34(1):15-24.
doi:10.1002/elan.202100362 .
Knežević, Sara, Ognjanović, Miloš, Gavrović-Jankulović, Marija, Đurašinović, Tatjana, Antić, Bratislav, Vranješ-Đurić, Sanja, Stanković, Dalibor M., "S-Adenosyl-L-Homocysteine Hydrolase Immobilized on Citric Acid-capped Gallium Oxyhydroxide on SWCNTs Modified Electrode for AdoHcy Impedimetric Sensing" in Electroanalysis, 34, no. 1 (2021):15-24,
https://doi.org/10.1002/elan.202100362 . .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB