Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization

Authorized Users Only
2020
Authors
Martinović, Biljana
Jelić, Ivana V.
Rikalović, Milena
Šljivić-Ivanović, Marija Z.
Radosavljević, Jelena
Kostić, Aleksandar Ž.
Adžemović, Mesud
Article (Published version)
Metadata
Show full item record
Abstract
The aim of the present study is the comparison of ambient pollution in working environment during infectious medical waste treatment in two relevant health care institutions in the Republic of Serbia - The Blood Transfusion Institute of Serbia and The Clinical Centre of Serbia by different sterilization methods (sterilizer-convertor and autoclave, respectively). Monitoring and analysis of the following chemical compounds were performed in both institutions: water vapor, carbon dioxide, carbon monoxide, hydrochloric acid, methane, ethane, propane, hexane, formaldehyde, benzene, toluene, m-xylene, phenol, acrolein, ethanol, ethyl acetate, ethylamine, ethylene oxide, methanol, dimethyl disulphide, dimethyl sulphide, ethyl mercaptan, methyl mercaptan, freon 11 (trichlorofluoromethane), carbonyl sulphide and hydrogen chloride. The determination of vapor-phase concentrations was done by extractive Fourier transform infrared spectroscopy. Monitoring of ambient pollution during infectious medi...cal waste sterilization has shown that mercaptans, acrolein, formaldehyde, dimethyl sulphide, and ethylene oxide are emitted in both health institutions, in concentrations which are not permitted by regulations, while increased concentrations of hydrogen chloride and phenol were found in the Clinical Centre of Serbia. A comparison of ambient pollution with two different sterilization methods has shown that higher concentrations of pollutants are emitted at higher temperatures. Considering the fact that mentioned compounds exhibit high toxicity, hence represent the risk to air quality in working and living environment, i.e. represents a risk to human health it is necessary to revise and improve the existing treatment methods. © 2020 Parlar Scientific Publications. All rights reserved.

Keywords:
Ambient pollution / In site / Infectious / Sterilization / VOCs / Waste / Working environment
Source:
Fresenius Environmental Bulletin, 2020, 29, 4, 2160-2165
Funding / projects:
  • Developing technological processes for nonstandard copper concentrates processing with the aim to decrease pollutants emission (RS-34023)
  • Advanced technologies for monitoring and environmental protection from chemical pollutants and radiation burden (RS-43009)

ISSN: 1018-4619

WoS: 000535839500020

Scopus: 2-s2.0-85090578937
[ Google Scholar ]
1
1
Handle
https://hdl.handle.net/21.15107/rcub_vinar_9640
URI
https://vinar.vin.bg.ac.rs/handle/123456789/9640
Collections
  • Radovi istraživača
Institution/Community
Vinča
TY  - JOUR
AU  - Martinović, Biljana
AU  - Jelić, Ivana V.
AU  - Rikalović, Milena
AU  - Šljivić-Ivanović, Marija Z.
AU  - Radosavljević, Jelena
AU  - Kostić, Aleksandar Ž.
AU  - Adžemović, Mesud
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9640
AB  - The aim of the present study is the comparison of ambient pollution in working environment during infectious medical waste treatment in two relevant health care institutions in the Republic of Serbia - The Blood Transfusion Institute of Serbia and The Clinical Centre of Serbia by different sterilization methods (sterilizer-convertor and autoclave, respectively). Monitoring and analysis of the following chemical compounds were performed in both institutions: water vapor, carbon dioxide, carbon monoxide, hydrochloric acid, methane, ethane, propane, hexane, formaldehyde, benzene, toluene, m-xylene, phenol, acrolein, ethanol, ethyl acetate, ethylamine, ethylene oxide, methanol, dimethyl disulphide, dimethyl sulphide, ethyl mercaptan, methyl mercaptan, freon 11 (trichlorofluoromethane), carbonyl sulphide and hydrogen chloride. The determination of vapor-phase concentrations was done by extractive Fourier transform infrared spectroscopy. Monitoring of ambient pollution during infectious medical waste sterilization has shown that mercaptans, acrolein, formaldehyde, dimethyl sulphide, and ethylene oxide are emitted in both health institutions, in concentrations which are not permitted by regulations, while increased concentrations of hydrogen chloride and phenol were found in the Clinical Centre of Serbia. A comparison of ambient pollution with two different sterilization methods has shown that higher concentrations of pollutants are emitted at higher temperatures. Considering the fact that mentioned compounds exhibit high toxicity, hence represent the risk to air quality in working and living environment, i.e. represents a risk to human health it is necessary to revise and improve the existing treatment methods. © 2020 Parlar Scientific Publications. All rights reserved.
T2  - Fresenius Environmental Bulletin
T1  - Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization
VL  - 29
IS  - 4
SP  - 2160
EP  - 2165
UR  - https://hdl.handle.net/21.15107/rcub_vinar_9640
ER  - 
@article{
author = "Martinović, Biljana and Jelić, Ivana V. and Rikalović, Milena and Šljivić-Ivanović, Marija Z. and Radosavljević, Jelena and Kostić, Aleksandar Ž. and Adžemović, Mesud",
year = "2020",
abstract = "The aim of the present study is the comparison of ambient pollution in working environment during infectious medical waste treatment in two relevant health care institutions in the Republic of Serbia - The Blood Transfusion Institute of Serbia and The Clinical Centre of Serbia by different sterilization methods (sterilizer-convertor and autoclave, respectively). Monitoring and analysis of the following chemical compounds were performed in both institutions: water vapor, carbon dioxide, carbon monoxide, hydrochloric acid, methane, ethane, propane, hexane, formaldehyde, benzene, toluene, m-xylene, phenol, acrolein, ethanol, ethyl acetate, ethylamine, ethylene oxide, methanol, dimethyl disulphide, dimethyl sulphide, ethyl mercaptan, methyl mercaptan, freon 11 (trichlorofluoromethane), carbonyl sulphide and hydrogen chloride. The determination of vapor-phase concentrations was done by extractive Fourier transform infrared spectroscopy. Monitoring of ambient pollution during infectious medical waste sterilization has shown that mercaptans, acrolein, formaldehyde, dimethyl sulphide, and ethylene oxide are emitted in both health institutions, in concentrations which are not permitted by regulations, while increased concentrations of hydrogen chloride and phenol were found in the Clinical Centre of Serbia. A comparison of ambient pollution with two different sterilization methods has shown that higher concentrations of pollutants are emitted at higher temperatures. Considering the fact that mentioned compounds exhibit high toxicity, hence represent the risk to air quality in working and living environment, i.e. represents a risk to human health it is necessary to revise and improve the existing treatment methods. © 2020 Parlar Scientific Publications. All rights reserved.",
journal = "Fresenius Environmental Bulletin",
title = "Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization",
volume = "29",
number = "4",
pages = "2160-2165",
url = "https://hdl.handle.net/21.15107/rcub_vinar_9640"
}
Martinović, B., Jelić, I. V., Rikalović, M., Šljivić-Ivanović, M. Z., Radosavljević, J., Kostić, A. Ž.,& Adžemović, M.. (2020). Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization. in Fresenius Environmental Bulletin, 29(4), 2160-2165.
https://hdl.handle.net/21.15107/rcub_vinar_9640
Martinović B, Jelić IV, Rikalović M, Šljivić-Ivanović MZ, Radosavljević J, Kostić AŽ, Adžemović M. Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization. in Fresenius Environmental Bulletin. 2020;29(4):2160-2165.
https://hdl.handle.net/21.15107/rcub_vinar_9640 .
Martinović, Biljana, Jelić, Ivana V., Rikalović, Milena, Šljivić-Ivanović, Marija Z., Radosavljević, Jelena, Kostić, Aleksandar Ž., Adžemović, Mesud, "Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization" in Fresenius Environmental Bulletin, 29, no. 4 (2020):2160-2165,
https://hdl.handle.net/21.15107/rcub_vinar_9640 .

DSpace software copyright © 2002-2015  DuraSpace
About the VinaR Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the VinaR Repository | Send Feedback

OpenAIRERCUB