Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization
Само за регистроване кориснике
2020
Аутори
Martinović, BiljanaJelić, Ivana V.
Rikalović, Milena
Šljivić-Ivanović, Marija Z.
Radosavljević, Jelena
Kostić, Aleksandar Ž.
Adžemović, Mesud
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The aim of the present study is the comparison of ambient pollution in working environment during infectious medical waste treatment in two relevant health care institutions in the Republic of Serbia - The Blood Transfusion Institute of Serbia and The Clinical Centre of Serbia by different sterilization methods (sterilizer-convertor and autoclave, respectively). Monitoring and analysis of the following chemical compounds were performed in both institutions: water vapor, carbon dioxide, carbon monoxide, hydrochloric acid, methane, ethane, propane, hexane, formaldehyde, benzene, toluene, m-xylene, phenol, acrolein, ethanol, ethyl acetate, ethylamine, ethylene oxide, methanol, dimethyl disulphide, dimethyl sulphide, ethyl mercaptan, methyl mercaptan, freon 11 (trichlorofluoromethane), carbonyl sulphide and hydrogen chloride. The determination of vapor-phase concentrations was done by extractive Fourier transform infrared spectroscopy. Monitoring of ambient pollution during infectious medi...cal waste sterilization has shown that mercaptans, acrolein, formaldehyde, dimethyl sulphide, and ethylene oxide are emitted in both health institutions, in concentrations which are not permitted by regulations, while increased concentrations of hydrogen chloride and phenol were found in the Clinical Centre of Serbia. A comparison of ambient pollution with two different sterilization methods has shown that higher concentrations of pollutants are emitted at higher temperatures. Considering the fact that mentioned compounds exhibit high toxicity, hence represent the risk to air quality in working and living environment, i.e. represents a risk to human health it is necessary to revise and improve the existing treatment methods. © 2020 Parlar Scientific Publications. All rights reserved.
Кључне речи:
Ambient pollution / In site / Infectious / Sterilization / VOCs / Waste / Working environmentИзвор:
Fresenius Environmental Bulletin, 2020, 29, 4, 2160-2165Финансирање / пројекти:
- Развој технолошких процеса прераде нестандардних концентрата бакра у циљу оптимизације емисије загађујућих материја (RS-MESTD-Technological Development (TD or TR)-34023)
- Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)
Напомена:
- Available at: https://www.prt-parlar.de/
Колекције
Институција/група
VinčaTY - JOUR AU - Martinović, Biljana AU - Jelić, Ivana V. AU - Rikalović, Milena AU - Šljivić-Ivanović, Marija Z. AU - Radosavljević, Jelena AU - Kostić, Aleksandar Ž. AU - Adžemović, Mesud PY - 2020 UR - https://vinar.vin.bg.ac.rs/handle/123456789/9640 AB - The aim of the present study is the comparison of ambient pollution in working environment during infectious medical waste treatment in two relevant health care institutions in the Republic of Serbia - The Blood Transfusion Institute of Serbia and The Clinical Centre of Serbia by different sterilization methods (sterilizer-convertor and autoclave, respectively). Monitoring and analysis of the following chemical compounds were performed in both institutions: water vapor, carbon dioxide, carbon monoxide, hydrochloric acid, methane, ethane, propane, hexane, formaldehyde, benzene, toluene, m-xylene, phenol, acrolein, ethanol, ethyl acetate, ethylamine, ethylene oxide, methanol, dimethyl disulphide, dimethyl sulphide, ethyl mercaptan, methyl mercaptan, freon 11 (trichlorofluoromethane), carbonyl sulphide and hydrogen chloride. The determination of vapor-phase concentrations was done by extractive Fourier transform infrared spectroscopy. Monitoring of ambient pollution during infectious medical waste sterilization has shown that mercaptans, acrolein, formaldehyde, dimethyl sulphide, and ethylene oxide are emitted in both health institutions, in concentrations which are not permitted by regulations, while increased concentrations of hydrogen chloride and phenol were found in the Clinical Centre of Serbia. A comparison of ambient pollution with two different sterilization methods has shown that higher concentrations of pollutants are emitted at higher temperatures. Considering the fact that mentioned compounds exhibit high toxicity, hence represent the risk to air quality in working and living environment, i.e. represents a risk to human health it is necessary to revise and improve the existing treatment methods. © 2020 Parlar Scientific Publications. All rights reserved. T2 - Fresenius Environmental Bulletin T1 - Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization VL - 29 IS - 4 SP - 2160 EP - 2165 UR - https://hdl.handle.net/21.15107/rcub_vinar_9640 ER -
@article{ author = "Martinović, Biljana and Jelić, Ivana V. and Rikalović, Milena and Šljivić-Ivanović, Marija Z. and Radosavljević, Jelena and Kostić, Aleksandar Ž. and Adžemović, Mesud", year = "2020", abstract = "The aim of the present study is the comparison of ambient pollution in working environment during infectious medical waste treatment in two relevant health care institutions in the Republic of Serbia - The Blood Transfusion Institute of Serbia and The Clinical Centre of Serbia by different sterilization methods (sterilizer-convertor and autoclave, respectively). Monitoring and analysis of the following chemical compounds were performed in both institutions: water vapor, carbon dioxide, carbon monoxide, hydrochloric acid, methane, ethane, propane, hexane, formaldehyde, benzene, toluene, m-xylene, phenol, acrolein, ethanol, ethyl acetate, ethylamine, ethylene oxide, methanol, dimethyl disulphide, dimethyl sulphide, ethyl mercaptan, methyl mercaptan, freon 11 (trichlorofluoromethane), carbonyl sulphide and hydrogen chloride. The determination of vapor-phase concentrations was done by extractive Fourier transform infrared spectroscopy. Monitoring of ambient pollution during infectious medical waste sterilization has shown that mercaptans, acrolein, formaldehyde, dimethyl sulphide, and ethylene oxide are emitted in both health institutions, in concentrations which are not permitted by regulations, while increased concentrations of hydrogen chloride and phenol were found in the Clinical Centre of Serbia. A comparison of ambient pollution with two different sterilization methods has shown that higher concentrations of pollutants are emitted at higher temperatures. Considering the fact that mentioned compounds exhibit high toxicity, hence represent the risk to air quality in working and living environment, i.e. represents a risk to human health it is necessary to revise and improve the existing treatment methods. © 2020 Parlar Scientific Publications. All rights reserved.", journal = "Fresenius Environmental Bulletin", title = "Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization", volume = "29", number = "4", pages = "2160-2165", url = "https://hdl.handle.net/21.15107/rcub_vinar_9640" }
Martinović, B., Jelić, I. V., Rikalović, M., Šljivić-Ivanović, M. Z., Radosavljević, J., Kostić, A. Ž.,& Adžemović, M.. (2020). Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization. in Fresenius Environmental Bulletin, 29(4), 2160-2165. https://hdl.handle.net/21.15107/rcub_vinar_9640
Martinović B, Jelić IV, Rikalović M, Šljivić-Ivanović MZ, Radosavljević J, Kostić AŽ, Adžemović M. Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization. in Fresenius Environmental Bulletin. 2020;29(4):2160-2165. https://hdl.handle.net/21.15107/rcub_vinar_9640 .
Martinović, Biljana, Jelić, Ivana V., Rikalović, Milena, Šljivić-Ivanović, Marija Z., Radosavljević, Jelena, Kostić, Aleksandar Ž., Adžemović, Mesud, "Comparison of air pollution in the working environment during in site treatment of infectious medical waste by convertor and autoclave sterilization" in Fresenius Environmental Bulletin, 29, no. 4 (2020):2160-2165, https://hdl.handle.net/21.15107/rcub_vinar_9640 .