Atmospheric pure argon plasma without analyte water solution injection has been exposed to power interruption experiments in order to study the difference between electron and gas temperature. The arc plasma was studied in low currents range, between 3 and 10 A. Obtained temperature difference ranges from 3000 to 1500 K, from low to high current. A comparison with previous results, for argon plasma with water aerosol supply, have shown that introduction of water reduces temperature difference.
Извор:
Physical chemistry 2004: 7th international conference on fundemental and applied aspract of physical chemistry, 2004, 1, 104-106Издавач:
- Society of Physical Chemists of Serbia
Финансирање / пројекти:
- Ministry of Science and Environmental Protection of Republic of Serbia [Project No. 1928]
Напомена:
- Physical chemistry 2004 : 7th international conference on fundamental and applied aspects of physical chemistry; Belgrade (Serbia); 21-23 September 2004
Колекције
Институција/група
VinčaTY - CONF AU - Kuzmanović, Miroslav M. AU - Pavlović, Mirjana S. AU - Savović, Jelena AU - Stoiljković, Milovan AU - Antić-Jovanović, Ankica PY - 2004 UR - https://vinar.vin.bg.ac.rs/handle/123456789/9482 AB - Atmospheric pure argon plasma without analyte water solution injection has been exposed to power interruption experiments in order to study the difference between electron and gas temperature. The arc plasma was studied in low currents range, between 3 and 10 A. Obtained temperature difference ranges from 3000 to 1500 K, from low to high current. A comparison with previous results, for argon plasma with water aerosol supply, have shown that introduction of water reduces temperature difference. PB - Society of Physical Chemists of Serbia C3 - Physical chemistry 2004: 7th international conference on fundemental and applied aspract of physical chemistry T1 - Electron and gas temperature difference in low current argon d.c. arc studied by power interruption technique VL - 1 SP - 104 EP - 106 UR - https://hdl.handle.net/21.15107/rcub_vinar_9482 ER -
@conference{ author = "Kuzmanović, Miroslav M. and Pavlović, Mirjana S. and Savović, Jelena and Stoiljković, Milovan and Antić-Jovanović, Ankica", year = "2004", abstract = "Atmospheric pure argon plasma without analyte water solution injection has been exposed to power interruption experiments in order to study the difference between electron and gas temperature. The arc plasma was studied in low currents range, between 3 and 10 A. Obtained temperature difference ranges from 3000 to 1500 K, from low to high current. A comparison with previous results, for argon plasma with water aerosol supply, have shown that introduction of water reduces temperature difference.", publisher = "Society of Physical Chemists of Serbia", journal = "Physical chemistry 2004: 7th international conference on fundemental and applied aspract of physical chemistry", title = "Electron and gas temperature difference in low current argon d.c. arc studied by power interruption technique", volume = "1", pages = "104-106", url = "https://hdl.handle.net/21.15107/rcub_vinar_9482" }
Kuzmanović, M. M., Pavlović, M. S., Savović, J., Stoiljković, M.,& Antić-Jovanović, A.. (2004). Electron and gas temperature difference in low current argon d.c. arc studied by power interruption technique. in Physical chemistry 2004: 7th international conference on fundemental and applied aspract of physical chemistry Society of Physical Chemists of Serbia., 1, 104-106. https://hdl.handle.net/21.15107/rcub_vinar_9482
Kuzmanović MM, Pavlović MS, Savović J, Stoiljković M, Antić-Jovanović A. Electron and gas temperature difference in low current argon d.c. arc studied by power interruption technique. in Physical chemistry 2004: 7th international conference on fundemental and applied aspract of physical chemistry. 2004;1:104-106. https://hdl.handle.net/21.15107/rcub_vinar_9482 .
Kuzmanović, Miroslav M., Pavlović, Mirjana S., Savović, Jelena, Stoiljković, Milovan, Antić-Jovanović, Ankica, "Electron and gas temperature difference in low current argon d.c. arc studied by power interruption technique" in Physical chemistry 2004: 7th international conference on fundemental and applied aspract of physical chemistry, 1 (2004):104-106, https://hdl.handle.net/21.15107/rcub_vinar_9482 .