Radon measurements using open-faced charcoal canisters - Measurement uncertainty and method optimization

Само за регистроване кориснике
2020
Аутори
Živanović, Miloš Z.
Pantelić, Gordana K.
Čeliković, Igor T.
Krneta-Nikolić, Jelena D.
Vukanac, Ivana
Kržanović, Nikola
Чланак у часопису (Објављена верзија)
,
© 2020 Elsevier Ltd
Метаподаци
Приказ свих података о документу
Апстракт
Open-faced charcoal canisters have been used for radon measurements for over 40 years. This method is sensitive to temperature, changing radon concentrations, humidity and other parameters, but a comprehensive study dealing with the influence quantities and measurement uncertainty was not available in literature. In this paper, all the identified influence quantities are discussed in detail, uncertainty budget is developed, good practice and bad practice examples are introduced and new recommendations are proposed to optimize the method and reduce uncertainty.
Кључне речи:
Radon / Indoor / Measurement uncertainty / Optimization / Charcoal canisters / Open-faced
Извор:
Applied Radiation and Isotopes, 2020, 165, 109335-
Финансирање / пројекти:
  • Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)
  • Нуклеарна физика, методе и примена (RS-MESTD-Basic Research (BR or ON)-171018)

DOI: 10.1016/j.apradiso.2020.109335

ISSN: 0969-8043

PubMed: 32777742

WoS: 000568698100023

Scopus: 2-s2.0-85089024367
[ Google Scholar ]
5
4
URI
https://vinar.vin.bg.ac.rs/handle/123456789/9113
Колекције
  • 011 - Laboratorija za nuklearnu i plazma fiziku
  • 100 - Laboratorija za zaštitu od zračenja i zaštitu životne sredine
  • Radovi istraživača
Институција/група
Vinča
TY  - JOUR
AU  - Živanović, Miloš Z.
AU  - Pantelić, Gordana K.
AU  - Čeliković, Igor T.
AU  - Krneta-Nikolić, Jelena D.
AU  - Vukanac, Ivana
AU  - Kržanović, Nikola
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/9113
AB  - Open-faced charcoal canisters have been used for radon measurements for over 40 years. This method is sensitive to temperature, changing radon concentrations, humidity and other parameters, but a comprehensive study dealing with the influence quantities and measurement uncertainty was not available in literature. In this paper, all the identified influence quantities are discussed in detail, uncertainty budget is developed, good practice and bad practice examples are introduced and new recommendations are proposed to optimize the method and reduce uncertainty.
T2  - Applied Radiation and Isotopes
T1  - Radon measurements using open-faced charcoal canisters - Measurement uncertainty and method optimization
VL  - 165
SP  - 109335
DO  - 10.1016/j.apradiso.2020.109335
ER  - 
@article{
author = "Živanović, Miloš Z. and Pantelić, Gordana K. and Čeliković, Igor T. and Krneta-Nikolić, Jelena D. and Vukanac, Ivana and Kržanović, Nikola",
year = "2020",
abstract = "Open-faced charcoal canisters have been used for radon measurements for over 40 years. This method is sensitive to temperature, changing radon concentrations, humidity and other parameters, but a comprehensive study dealing with the influence quantities and measurement uncertainty was not available in literature. In this paper, all the identified influence quantities are discussed in detail, uncertainty budget is developed, good practice and bad practice examples are introduced and new recommendations are proposed to optimize the method and reduce uncertainty.",
journal = "Applied Radiation and Isotopes",
title = "Radon measurements using open-faced charcoal canisters - Measurement uncertainty and method optimization",
volume = "165",
pages = "109335",
doi = "10.1016/j.apradiso.2020.109335"
}
Živanović, M. Z., Pantelić, G. K., Čeliković, I. T., Krneta-Nikolić, J. D., Vukanac, I.,& Kržanović, N.. (2020). Radon measurements using open-faced charcoal canisters - Measurement uncertainty and method optimization. in Applied Radiation and Isotopes, 165, 109335.
https://doi.org/10.1016/j.apradiso.2020.109335
Živanović MZ, Pantelić GK, Čeliković IT, Krneta-Nikolić JD, Vukanac I, Kržanović N. Radon measurements using open-faced charcoal canisters - Measurement uncertainty and method optimization. in Applied Radiation and Isotopes. 2020;165:109335.
doi:10.1016/j.apradiso.2020.109335 .
Živanović, Miloš Z., Pantelić, Gordana K., Čeliković, Igor T., Krneta-Nikolić, Jelena D., Vukanac, Ivana, Kržanović, Nikola, "Radon measurements using open-faced charcoal canisters - Measurement uncertainty and method optimization" in Applied Radiation and Isotopes, 165 (2020):109335,
https://doi.org/10.1016/j.apradiso.2020.109335 . .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB