Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter
Аутори
Sirunyan, A. M.Tumasyan, A.
Adam, W.
Ambrogi, F.
Bergauer, T.
Adžić, Petar
Ćirković, Predrag
Đorđević, Miloš
Milenović, Predrag
Milošević, Jovan
Stojanović, Milan
Devetak, Damir
Остала ауторства
CMS CollaborationЧланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb-1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: A laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.
Извор:
Journal of Instrumentation, 2020Напомена:
- CMS Collaboration (ukupan broj autora: 2304)
DOI: 10.1088/1748-0221/15/06/P06009
ISSN: 1748-0221
WoS: 000545350900009
Scopus: 2-s2.0-85088533574
Колекције
Институција/група
VinčaTY - JOUR AU - Sirunyan, A. M. AU - Tumasyan, A. AU - Adam, W. AU - Ambrogi, F. AU - Bergauer, T. AU - Adžić, Petar AU - Ćirković, Predrag AU - Đorđević, Miloš AU - Milenović, Predrag AU - Milošević, Jovan AU - Stojanović, Milan AU - Devetak, Damir PY - 2020 UR - https://vinar.vin.bg.ac.rs/handle/123456789/9095 AB - Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb-1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: A laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate. T2 - Journal of Instrumentation T1 - Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter DO - 10.1088/1748-0221/15/06/P06009 ER -
@article{ author = "Sirunyan, A. M. and Tumasyan, A. and Adam, W. and Ambrogi, F. and Bergauer, T. and Adžić, Petar and Ćirković, Predrag and Đorđević, Miloš and Milenović, Predrag and Milošević, Jovan and Stojanović, Milan and Devetak, Damir", year = "2020", abstract = "Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb-1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: A laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.", journal = "Journal of Instrumentation", title = "Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter", doi = "10.1088/1748-0221/15/06/P06009" }
Sirunyan, A. M., Tumasyan, A., Adam, W., Ambrogi, F., Bergauer, T., Adžić, P., Ćirković, P., Đorđević, M., Milenović, P., Milošević, J., Stojanović, M.,& Devetak, D.. (2020). Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter. in Journal of Instrumentation. https://doi.org/10.1088/1748-0221/15/06/P06009
Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Bergauer T, Adžić P, Ćirković P, Đorđević M, Milenović P, Milošević J, Stojanović M, Devetak D. Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter. in Journal of Instrumentation. 2020;. doi:10.1088/1748-0221/15/06/P06009 .
Sirunyan, A. M., Tumasyan, A., Adam, W., Ambrogi, F., Bergauer, T., Adžić, Petar, Ćirković, Predrag, Đorđević, Miloš, Milenović, Predrag, Milošević, Jovan, Stojanović, Milan, Devetak, Damir, "Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter" in Journal of Instrumentation (2020), https://doi.org/10.1088/1748-0221/15/06/P06009 . .