Show simple item record

dc.creatorKnežević, Sara
dc.creatorOgnjanović, Miloš
dc.creatorNedić, Nemanja
dc.creatorMariano, Jose F. M. L.
dc.creatorMilanović, Zorana
dc.creatorPetković, Branka B.
dc.creatorAntić, Bratislav
dc.creatorVranješ-Đurić, Sanja
dc.creatorStanković, Dalibor M.
dc.date.accessioned2020-10-14T06:34:47Z
dc.date.available2020-10-14T06:34:47Z
dc.date.issued2020
dc.identifier.issn0026-265X
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/8834
dc.description.abstractIn order to ensure high food quality, one of the prime importance is the detection and quantification of histamine, well known marine food poison. In this work, we constructed novel electrochemical biosensor for the detection of histamine based on gold nanoparticles decorated on manganese dioxide (Au/MnO2) and used for modification of screen-printed carbon electrode (Au/MnO2@SPCE). The constructed sensor was then used for the estimation of histamine content in a single drop. Materials used in this study were synthesized and characterized using HR-TEM, XRPD and electrochemical methods. The amperometric detection method was optimized and, under selected operating parameters (supporting electrolyte pH 6, working potential of 1 V), the proposed sensor possesses linear working range from 0.3 µM to 5.1 µM, with a detection limit of 0.08 µM. The effect of selected interferences was investigated and it was found that the developed approach offers accurate, precise, selective, fast and reproducible quantification of histamine using only one drop of the sample. In the end, this work stands as a proof-of-concept of the modified electrodes and electrochemical detection as a promising and prospective approach for the applications in real-time monitoring of the food quality.en
dc.relationEUREKA project E! 13303 MED-BIO-TEST
dc.rightsrestrictedAccess
dc.sourceMicrochemical Journal
dc.subjectElectrochemistryen
dc.subjectHistamineen
dc.subjectMarine food qualityen
dc.subjectScreen-printed electrodeen
dc.subjectSensorsen
dc.subjectSingle drop detectionen
dc.titleA single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrodeen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractМилановић, Зорана; Петковић, Бранка Б.; Aнтић, Братислав; Врањеш-Ђурић, Сања; Кнежевић, Сара; Недић, Немања; Мариано, Јосé Ф.М.Л.; Станковић, Далибор; Огњановић, Милош;
dc.citation.volume155
dc.citation.spage104778
dc.identifier.wos000527371500116
dc.identifier.doi10.1016/j.microc.2020.104778
dc.citation.rankM21~
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85080057724


Files in this item