Mathematical modelling and optimisation of lignite and wheat straw co-combustion in 350 MWe boiler furnace

Само за регистроване кориснике
2020
Аутори
Milićević, Aleksandar
Belošević, Srđan
Crnomarković, Nenad Đ.
Tomanović, Ivan D.
Tucaković, Dragan R.
Чланак у часопису (Објављена верзија)
,
© 2019 Elsevier B.V.
Метаподаци
Приказ свих података о документу
Апстракт
In this paper pulverised lignite-fired 350 MWe boiler furnace is selected for numerical simulations performed by using in-house developed computer code to deepen understanding of complex processes during direct co-firing with wheat straw. The CFD code is significantly upgraded to accommodate simulation of lignite and wheat straw particle reactions and interactions with gas phase, and to allow analysis of particle behavior under real conditions inside the furnace. Parametric analysis is done with emphasis on the thermal share, size and shape of biomass particle, method of biomass feeding into the furnace and the fuel distribution over the burner tiers. In the most favorable co-firing case (with 10% of wheat straw thermal ratio and particle diameter of 500 μm), the higher furnace exit gas temperature for 8 ˚C and lower NOx emission of 18.2% are achieved, compared with pure lignite combustion case. The optimal co-firing case provides relatively low percentage of wheat straw particles fall...ing into the hopper (9.57%) and relatively high mass burnout of biomass particles at the furnace outlet (91.81%). Non-spherical shape of wheat straw particles is found to affect the fuel trajectories and flame significantly. The results of parametric analysis could support implementation of biomass co-firing technology in existing coal-fired power plants, to increase energy efficiency and mitigate environmental pollutants. © 2019 Elsevier Ltd

Кључне речи:
Mathematical modelling / Pulverised coal / Co-combustion / Biomass / Numerical study / Utility steam boiler
Извор:
Applied Energy, 2020, 260, 114206-
Финансирање / пројекти:
  • Повећање енергетске и еколошке ефикасности процеса у ложишту за угљени прах и оптимизација излазне грејне површине енергетског парног котла применом сопствених софтверских алата (RS-MESTD-Technological Development (TD or TR)-33018)

DOI: 10.1016/j.apenergy.2019.114206

ISSN: 0306-2619

WoS: 000515108700083

Scopus: 2-s2.0-85077222376
[ Google Scholar ]
31
30
URI
https://vinar.vin.bg.ac.rs/handle/123456789/8785
Колекције
  • Radovi istraživača
Институција/група
Vinča
TY  - JOUR
AU  - Milićević, Aleksandar
AU  - Belošević, Srđan
AU  - Crnomarković, Nenad Đ.
AU  - Tomanović, Ivan D.
AU  - Tucaković, Dragan R.
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8785
AB  - In this paper pulverised lignite-fired 350 MWe boiler furnace is selected for numerical simulations performed by using in-house developed computer code to deepen understanding of complex processes during direct co-firing with wheat straw. The CFD code is significantly upgraded to accommodate simulation of lignite and wheat straw particle reactions and interactions with gas phase, and to allow analysis of particle behavior under real conditions inside the furnace. Parametric analysis is done with emphasis on the thermal share, size and shape of biomass particle, method of biomass feeding into the furnace and the fuel distribution over the burner tiers. In the most favorable co-firing case (with 10% of wheat straw thermal ratio and particle diameter of 500 μm), the higher furnace exit gas temperature for 8 ˚C and lower NOx emission of 18.2% are achieved, compared with pure lignite combustion case. The optimal co-firing case provides relatively low percentage of wheat straw particles falling into the hopper (9.57%) and relatively high mass burnout of biomass particles at the furnace outlet (91.81%). Non-spherical shape of wheat straw particles is found to affect the fuel trajectories and flame significantly. The results of parametric analysis could support implementation of biomass co-firing technology in existing coal-fired power plants, to increase energy efficiency and mitigate environmental pollutants. © 2019 Elsevier Ltd
T2  - Applied Energy
T1  - Mathematical modelling and optimisation of lignite and wheat straw co-combustion in 350 MWe boiler furnace
VL  - 260
SP  - 114206
DO  - 10.1016/j.apenergy.2019.114206
ER  - 
@article{
author = "Milićević, Aleksandar and Belošević, Srđan and Crnomarković, Nenad Đ. and Tomanović, Ivan D. and Tucaković, Dragan R.",
year = "2020",
abstract = "In this paper pulverised lignite-fired 350 MWe boiler furnace is selected for numerical simulations performed by using in-house developed computer code to deepen understanding of complex processes during direct co-firing with wheat straw. The CFD code is significantly upgraded to accommodate simulation of lignite and wheat straw particle reactions and interactions with gas phase, and to allow analysis of particle behavior under real conditions inside the furnace. Parametric analysis is done with emphasis on the thermal share, size and shape of biomass particle, method of biomass feeding into the furnace and the fuel distribution over the burner tiers. In the most favorable co-firing case (with 10% of wheat straw thermal ratio and particle diameter of 500 μm), the higher furnace exit gas temperature for 8 ˚C and lower NOx emission of 18.2% are achieved, compared with pure lignite combustion case. The optimal co-firing case provides relatively low percentage of wheat straw particles falling into the hopper (9.57%) and relatively high mass burnout of biomass particles at the furnace outlet (91.81%). Non-spherical shape of wheat straw particles is found to affect the fuel trajectories and flame significantly. The results of parametric analysis could support implementation of biomass co-firing technology in existing coal-fired power plants, to increase energy efficiency and mitigate environmental pollutants. © 2019 Elsevier Ltd",
journal = "Applied Energy",
title = "Mathematical modelling and optimisation of lignite and wheat straw co-combustion in 350 MWe boiler furnace",
volume = "260",
pages = "114206",
doi = "10.1016/j.apenergy.2019.114206"
}
Milićević, A., Belošević, S., Crnomarković, N. Đ., Tomanović, I. D.,& Tucaković, D. R.. (2020). Mathematical modelling and optimisation of lignite and wheat straw co-combustion in 350 MWe boiler furnace. in Applied Energy, 260, 114206.
https://doi.org/10.1016/j.apenergy.2019.114206
Milićević A, Belošević S, Crnomarković NĐ, Tomanović ID, Tucaković DR. Mathematical modelling and optimisation of lignite and wheat straw co-combustion in 350 MWe boiler furnace. in Applied Energy. 2020;260:114206.
doi:10.1016/j.apenergy.2019.114206 .
Milićević, Aleksandar, Belošević, Srđan, Crnomarković, Nenad Đ., Tomanović, Ivan D., Tucaković, Dragan R., "Mathematical modelling and optimisation of lignite and wheat straw co-combustion in 350 MWe boiler furnace" in Applied Energy, 260 (2020):114206,
https://doi.org/10.1016/j.apenergy.2019.114206 . .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB