Procena merne nesigurnosti pri merenju aktivnosti radiofarmaceutika u doze kalibratoru

Estimation of measurement uncertainty in measuring radiopharmaceutical activity in dose calibrator

Thumbnail
2019
XXX_Symphosium_DZZSCG_2019_366-372.pdf (1.226Mb)
Authors
Janković, Drina
Mirković, Marija D.
Radović, Magdalena
Milanović, Zorana
Perić, Marko R.
Vukadinović, Aleksandar
Vranješ-Đurić, Sanja
Conference object (Published version)
,
© Institut za nuklearne nauke "Vinča"
Metadata
Show full item record
Abstract
Doze kalibrator je jedan od osnovnih uređaja u nuklearnoj medicini, koji se koristi za merenje aktivnosti (doza) radiofarmaceutika koji se daju pacijentima bilo u dijagnostičke ili u terapijske svrhe. Aktivnosti gama i beta emitera različitih energija moraju da budu izmerene što tačnije da bi izlaganja ljudi (pacijenata) jonizujućem zračenju bila svedena na najmanji mogući nivo, a da se dobiju klinički značajni rezultati. Početna tačnost kalibratora (nesigurnost 5% ili manje) može se vremenom menjati kao rezultat promene pritiska u jonizacionoj komori ili električnog drifta. Zbog toga kontrola kvaliteta doze kalibratora treba da se sprovodi rutinski kako bi se osigurala tačnost i sledljivost merenja.U radu su prikazani rezultati procene nesigurnostipri merenjima aktivnosti radiofarmaceutika u doze kalibratoru u Laboratoriji za radioizotope. Komponente nesigurnosti, koje su važne za ova merenja, identifikuju se i uzimaju u obzir prilikom procene merne nesigurnosti. Razumevanje izvora ne...sigurnosti i korišćenje odgovarajućih korekcionih faktora mogu minimizirati netačna merenja.

A dose calibrator is an essential device in a nuclear medicine, utilized for measurement the activity of radiopharmaceuticals administered to patients both for diagnostic and therapeutic purposes. It has to measurethe radioactivity of gamma and beta with different energies precisely for high quality imaging and for applying the right amount of radiation to treat disease. Initial accuracy (uncertainty 5% or less) may change with time as a result of changing pressureof the chamber gas and slow electrical drift. The quality controls should be undertaken on a routine basis to ensure the accuracy and traceability of measurements of the activities of radiopharmaceuticals.The paper presents the results of estimation of uncertainty in the measurement of the activity in the dose calibrator in the Laboratory for radioisotopes. The uncertainty components, that are important for these measurements, are identified and taken into account while estimating the uncertainty of measurement. Understanding... the source of uncertainty and using appropriate techniques can minimize inaccurate measurements.

Source:
30. симпозијум ДЗЗСЦГ : зборник радова, 2019, 366-372
Publisher:
  • Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
Funding / projects:
  • Advanced technologies for monitoring and environmental protection from chemical pollutants and radiation burden (RS-43009)
Note:
  • Proceedings: http://vinar.vin.bg.ac.rs/handle/123456789/8681
  • XXX симпозијум ДЗЗСЦГ (Друштва за заштиту од зрачења Србије и Црне Горе), 2- 4. октобар 2019. године, Дивчибаре, Србија

ISBN: 978-86-7306-154-2

[ Google Scholar ]
Handle
https://hdl.handle.net/21.15107/rcub_vinar_8710
URI
https://plus.sr.cobiss.net/opac7/bib/279687436
https://vinar.vin.bg.ac.rs/handle/123456789/8710
Collections
  • Radovi istraživača
Institution/Community
Vinča
TY  - CONF
AU  - Janković, Drina
AU  - Mirković, Marija D.
AU  - Radović, Magdalena
AU  - Milanović, Zorana
AU  - Perić, Marko R.
AU  - Vukadinović, Aleksandar
AU  - Vranješ-Đurić, Sanja
PY  - 2019
UR  - https://plus.sr.cobiss.net/opac7/bib/279687436
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/8710
AB  - Doze kalibrator je jedan od osnovnih uređaja u nuklearnoj medicini, koji se koristi za merenje aktivnosti (doza) radiofarmaceutika koji se daju pacijentima bilo u dijagnostičke ili u terapijske svrhe. Aktivnosti gama i beta emitera različitih energija moraju da budu izmerene što tačnije da bi izlaganja ljudi (pacijenata) jonizujućem zračenju bila svedena na najmanji mogući nivo, a da se dobiju klinički značajni rezultati. Početna tačnost kalibratora (nesigurnost 5% ili manje) može se vremenom menjati kao rezultat promene pritiska u jonizacionoj komori ili električnog drifta. Zbog toga kontrola kvaliteta doze kalibratora treba da se sprovodi rutinski kako bi se osigurala tačnost i sledljivost merenja.U radu su prikazani rezultati procene nesigurnostipri merenjima aktivnosti radiofarmaceutika u doze kalibratoru u Laboratoriji za radioizotope. Komponente nesigurnosti, koje su važne za ova merenja, identifikuju se i uzimaju u obzir prilikom procene merne nesigurnosti. Razumevanje izvora nesigurnosti i korišćenje odgovarajućih korekcionih faktora mogu minimizirati netačna merenja.
AB  - A dose calibrator is an essential device in a nuclear medicine, utilized for measurement the activity of radiopharmaceuticals administered to patients both for diagnostic and therapeutic purposes. It has to measurethe radioactivity of gamma and beta with different energies precisely for high quality imaging and for applying the right amount of radiation to treat disease. Initial accuracy (uncertainty 5% or less) may change with time as a result of changing pressureof the chamber gas and slow electrical drift. The quality controls should be undertaken on a routine basis to ensure the accuracy and traceability of measurements of the activities of radiopharmaceuticals.The paper presents the results of estimation of uncertainty in the measurement of the activity in the dose calibrator in the Laboratory for radioisotopes. The uncertainty components, that are important for these measurements, are identified and taken into account while estimating the uncertainty of measurement. Understanding the source of uncertainty and using appropriate techniques can minimize inaccurate measurements.
PB  - Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
C3  - 30. симпозијум ДЗЗСЦГ : зборник радова
T1  - Procena merne nesigurnosti pri merenju aktivnosti radiofarmaceutika u doze kalibratoru
T1  - Estimation of measurement uncertainty in measuring radiopharmaceutical activity in dose calibrator
SP  - 366
EP  - 372
UR  - https://hdl.handle.net/21.15107/rcub_vinar_8710
ER  - 
@conference{
author = "Janković, Drina and Mirković, Marija D. and Radović, Magdalena and Milanović, Zorana and Perić, Marko R. and Vukadinović, Aleksandar and Vranješ-Đurić, Sanja",
year = "2019",
abstract = "Doze kalibrator je jedan od osnovnih uređaja u nuklearnoj medicini, koji se koristi za merenje aktivnosti (doza) radiofarmaceutika koji se daju pacijentima bilo u dijagnostičke ili u terapijske svrhe. Aktivnosti gama i beta emitera različitih energija moraju da budu izmerene što tačnije da bi izlaganja ljudi (pacijenata) jonizujućem zračenju bila svedena na najmanji mogući nivo, a da se dobiju klinički značajni rezultati. Početna tačnost kalibratora (nesigurnost 5% ili manje) može se vremenom menjati kao rezultat promene pritiska u jonizacionoj komori ili električnog drifta. Zbog toga kontrola kvaliteta doze kalibratora treba da se sprovodi rutinski kako bi se osigurala tačnost i sledljivost merenja.U radu su prikazani rezultati procene nesigurnostipri merenjima aktivnosti radiofarmaceutika u doze kalibratoru u Laboratoriji za radioizotope. Komponente nesigurnosti, koje su važne za ova merenja, identifikuju se i uzimaju u obzir prilikom procene merne nesigurnosti. Razumevanje izvora nesigurnosti i korišćenje odgovarajućih korekcionih faktora mogu minimizirati netačna merenja., A dose calibrator is an essential device in a nuclear medicine, utilized for measurement the activity of radiopharmaceuticals administered to patients both for diagnostic and therapeutic purposes. It has to measurethe radioactivity of gamma and beta with different energies precisely for high quality imaging and for applying the right amount of radiation to treat disease. Initial accuracy (uncertainty 5% or less) may change with time as a result of changing pressureof the chamber gas and slow electrical drift. The quality controls should be undertaken on a routine basis to ensure the accuracy and traceability of measurements of the activities of radiopharmaceuticals.The paper presents the results of estimation of uncertainty in the measurement of the activity in the dose calibrator in the Laboratory for radioisotopes. The uncertainty components, that are important for these measurements, are identified and taken into account while estimating the uncertainty of measurement. Understanding the source of uncertainty and using appropriate techniques can minimize inaccurate measurements.",
publisher = "Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе",
journal = "30. симпозијум ДЗЗСЦГ : зборник радова",
title = "Procena merne nesigurnosti pri merenju aktivnosti radiofarmaceutika u doze kalibratoru, Estimation of measurement uncertainty in measuring radiopharmaceutical activity in dose calibrator",
pages = "366-372",
url = "https://hdl.handle.net/21.15107/rcub_vinar_8710"
}
Janković, D., Mirković, M. D., Radović, M., Milanović, Z., Perić, M. R., Vukadinović, A.,& Vranješ-Đurić, S.. (2019). Procena merne nesigurnosti pri merenju aktivnosti radiofarmaceutika u doze kalibratoru. in 30. симпозијум ДЗЗСЦГ : зборник радова
Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе., 366-372.
https://hdl.handle.net/21.15107/rcub_vinar_8710
Janković D, Mirković MD, Radović M, Milanović Z, Perić MR, Vukadinović A, Vranješ-Đurić S. Procena merne nesigurnosti pri merenju aktivnosti radiofarmaceutika u doze kalibratoru. in 30. симпозијум ДЗЗСЦГ : зборник радова. 2019;:366-372.
https://hdl.handle.net/21.15107/rcub_vinar_8710 .
Janković, Drina, Mirković, Marija D., Radović, Magdalena, Milanović, Zorana, Perić, Marko R., Vukadinović, Aleksandar, Vranješ-Đurić, Sanja, "Procena merne nesigurnosti pri merenju aktivnosti radiofarmaceutika u doze kalibratoru" in 30. симпозијум ДЗЗСЦГ : зборник радова (2019):366-372,
https://hdl.handle.net/21.15107/rcub_vinar_8710 .

DSpace software copyright © 2002-2015  DuraSpace