dc.description.abstract | The aim of this paper is to examine the energy and angular responses of thermoluminescent dosimeters containing either MTS-N (LiF:Mg,Ti) or MCP-N (LiF:Mg,Cu,P) detector materials, and of the InLight optically stimulated luminescent dosimeters containing Al2O3:C detectors. Ten radiation qualities, with mean energies ranging from 24 keV to 1.25 MeV, and five angles of incidence, between 0° and 80°, were used for this purpose. The dosimeter response measure of quality were the IEC 62387 requirements. The experimental results show that the MTS-N-based and the InLight dosimeters performed in line with the standard's criteria. On the other hand, the MCP-N-based dosimeters exhibited a pronounced under-response around the energy of 120 keV, which resulted in deviations from the standard's conditions for both the energy and angular responses. © 2019 Elsevier Ltd | en |
dc.language.iso | en | |
dc.relation | info:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/171007/RS// | |
dc.relation | info:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/43009/RS// | |
dc.rights | restrictedAccess | |
dc.source | Applied Radiation and Isotopes | |
dc.subject | Angular response | en |
dc.subject | Energy response | en |
dc.subject | Optically stimulated luminescence | en |
dc.subject | Personal dosimetry | en |
dc.subject | Photon radiation | en |
dc.subject | Thermoluminescence | en |
dc.title | Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields | en |
dc.type | article | en |
dc.rights.license | ARR | |
dcterms.abstract | Кржановић, Никола; Станковић, Ковиљка; Aпостолакопоулос, Филип Хараламбос; Перазић, Лука; | |
dc.rights.holder | © 2019 Elsevier Ltd | |
dc.citation.volume | 151 | |
dc.citation.spage | 235 | |
dc.citation.epage | 241 | |
dc.identifier.wos | 000482244900033 | |
dc.identifier.doi | 10.1016/j.apradiso.2019.06.023 | |
dc.citation.rank | M22 | |
dc.identifier.pmid | 31228731 | |
dc.type.version | publishedVersion | |
dc.identifier.scopus | 2-s2.0-85067416124 |
Документи
Овај документ се појављује у следећим колекцијама
-
Radovi istraživača
Researchers' publications