Statistička analiza rezultata merenja intenziteta električnog polja u okolini baznih stanica
Statistical analysis of electric field strength measurements in the vicinity of base station
Authors
Koprivica, MladenPetrić, Majda
Slavković, Vladimir
Nešković, Nataša
Nešković, Aleksandar
Paunović, Đorđe
Conference object (Published version)
Metadata
Show full item recordAbstract
Statistička analiza rezultata merenja intenziteta električnog polja sprovedena je na 664
lokacije baznih stanica klasifikovane u tri kategorije. Rezultati merenja za kategoriju
stubovi pokazuju da ni u jednom slučaju ukupni intenzitet električnog polja ne prelazi
vrednost od 10V/m. Za kategoriju instalacije spolja na objektu, u slučaju outdoor
merenja, referentne granične vrednosti propisane ICNIRP preporukama prevaziđene su
u 2,5% lokacija, dok su vrednosti propisane Pravilnikom o granicama izlaganja
nejonizujućim zračenjima prevaziđene u 15,6% lokacija. Treba istaći da su ove
vrednosti izmerene na krovovima objekata, u zonama gde ljudi ne borave, i čak u većini
slučajeva nemaju pristup. Sa druge strane, indoor ukupni intenzitet polja koji potiče od
antena instaliranih spolja na objektu, nije prevazišao ICNIRP i Srpske norme. Na
određenom broju lokacija indoor mikro baznih stanica, maksimalna vrednost intenziteta
polja, izmerena na horizontalnoj udaljenosti do 1m prevazilaz...i norme propisane
ICNIRP preporukama i Pravilnikom. Apsolutna maksimalna vrednost prevazilazi
Srpske norme na približno 38% lokacija, i ICNIRP norme na približno 7% lokacija.
Statistical analysis of electric field strength measurements in the vicinity of base
stations was performed for 664 different locations, classified into three categories.
Measurement results for category masts showed that the total electric field strength did
not exceed in any case value of 10V/m. For category installations on buildings,
maximum recorded value has exceeded ICNIRP general public exposure reference
levels at 2.5% and Serbian national reference levels at 15.6% of all locations. It should
be emphasized that the values exceeding the reference levels were observed only
outdoor (in areas in which people do not reside and even in most cases do not have
access at all), while in indoor the total electric field strength in no case exceeded
defined reference levels. At certain number of analyzed locations for indoor microcell
base station, maximum values of electric field strength recorded within the horizontal
distance of 1 m from antenna, exceeded both the Serbian nat...ional (at 38% of locations)
and ICNIRP (7% of locations) reference levels.
Source:
29. симпозијум ДЗЗСЦГ : зборник радова, 2017, 589-599Publisher:
- Београд : Институт за нуклеарне науке "Винча" : Друштво за заштиту од зрачења Србије и Црне Горе
Note:
- Зборник радова : XXIX симпозијум ДЗЗСЦГ : Сребрно језеро, 27-29. септембар 2017. године