ВинаР - Репозиторијум Института за нуклеарне науке Винча
    • English
    • Српски
    • Српски (Serbia)
  • Српски (ћирилица) 
    • Енглески
    • Српски (ћирилица)
    • Српски (латиница)
  • Пријава
Преглед записа 
  •   ВинаР
  • Vinča
  • WoS Import
  • Преглед записа
  •   ВинаР
  • Vinča
  • WoS Import
  • Преглед записа
JavaScript is disabled for your browser. Some features of this site may not work without it.

Application of PHOTON simulation software on calibration of HPGe detectors

Нема приказа
Аутори
Krneta-Nikolić, Jelena D.
Puzović, Jovan M.
Todorović, Dragana
Rajačić, Milica
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
One of the major difficulties in gamma spectrometry of voluminous environmental samples is the efficiency calibration of the detectors used for the measurement. The direct measurement of different calibration sources, containing isolated gamma-ray emitters within the energy range of interest, and subsequent fitting to a parametric function, is the most accurate and at the same time most complicated and time consuming method of efficiency calibration. Many other methods are developed in time, some of them using Monte Carlo simulation. One of such methods is a dedicated and user-friendly program PHOTON, developed to simulate the passage of photons through different media with different geometries. This program was used for efficiency calibration of three HPGe detectors, readily used in Laboratory for Environment and Radiation Protection of the Institute for Nuclear Sciences Vinca, Belgrade, Serbia. The simulation produced the spectral response of the detectors for fixed energy and for di...fferent sample geometries and matrices. Thus obtained efficiencies were compared to the values obtained by the measurement of the secondary reference materials and to the results obtained by GEANT4 simulation, in order to establish whether the simulated values agree with the experimental ones. To further analyze the results, a realistic measurement of the materials provided by the IAEA within different interlaboratory proficiency tests, was performed. The activities obtained using simulated efficiencies were compared to the reference values provided by the organizer. A good agreement in the mid energy section of the spectrum was obtained, while for low energies the lack of some parameters in the simulation libraries proved to produce unacceptable discrepancies. (C) 2015 Elsevier B.V. All rights reserved.

Кључне речи:
HPGe / Calibration / PHOTON
Извор:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 2015, 799, 159-165
Финансирање / пројекти:
  • Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)

DOI: 10.1016/j.nima.2015.08.002

ISSN: 0168-9002; 1872-9576

WoS: 000361877300024

Scopus: 2-s2.0-84939798445
[ Google Scholar ]
5
5
URI
https://vinar.vin.bg.ac.rs/handle/123456789/753
Колекције
  • WoS Import
Институција/група
Vinča
TY  - JOUR
AU  - Krneta-Nikolić, Jelena D.
AU  - Puzović, Jovan M.
AU  - Todorović, Dragana
AU  - Rajačić, Milica
PY  - 2015
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/753
AB  - One of the major difficulties in gamma spectrometry of voluminous environmental samples is the efficiency calibration of the detectors used for the measurement. The direct measurement of different calibration sources, containing isolated gamma-ray emitters within the energy range of interest, and subsequent fitting to a parametric function, is the most accurate and at the same time most complicated and time consuming method of efficiency calibration. Many other methods are developed in time, some of them using Monte Carlo simulation. One of such methods is a dedicated and user-friendly program PHOTON, developed to simulate the passage of photons through different media with different geometries. This program was used for efficiency calibration of three HPGe detectors, readily used in Laboratory for Environment and Radiation Protection of the Institute for Nuclear Sciences Vinca, Belgrade, Serbia. The simulation produced the spectral response of the detectors for fixed energy and for different sample geometries and matrices. Thus obtained efficiencies were compared to the values obtained by the measurement of the secondary reference materials and to the results obtained by GEANT4 simulation, in order to establish whether the simulated values agree with the experimental ones. To further analyze the results, a realistic measurement of the materials provided by the IAEA within different interlaboratory proficiency tests, was performed. The activities obtained using simulated efficiencies were compared to the reference values provided by the organizer. A good agreement in the mid energy section of the spectrum was obtained, while for low energies the lack of some parameters in the simulation libraries proved to produce unacceptable discrepancies. (C) 2015 Elsevier B.V. All rights reserved.
T2  - Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
T1  - Application of PHOTON simulation software on calibration of HPGe detectors
VL  - 799
SP  - 159
EP  - 165
DO  - 10.1016/j.nima.2015.08.002
ER  - 
@article{
author = "Krneta-Nikolić, Jelena D. and Puzović, Jovan M. and Todorović, Dragana and Rajačić, Milica",
year = "2015",
abstract = "One of the major difficulties in gamma spectrometry of voluminous environmental samples is the efficiency calibration of the detectors used for the measurement. The direct measurement of different calibration sources, containing isolated gamma-ray emitters within the energy range of interest, and subsequent fitting to a parametric function, is the most accurate and at the same time most complicated and time consuming method of efficiency calibration. Many other methods are developed in time, some of them using Monte Carlo simulation. One of such methods is a dedicated and user-friendly program PHOTON, developed to simulate the passage of photons through different media with different geometries. This program was used for efficiency calibration of three HPGe detectors, readily used in Laboratory for Environment and Radiation Protection of the Institute for Nuclear Sciences Vinca, Belgrade, Serbia. The simulation produced the spectral response of the detectors for fixed energy and for different sample geometries and matrices. Thus obtained efficiencies were compared to the values obtained by the measurement of the secondary reference materials and to the results obtained by GEANT4 simulation, in order to establish whether the simulated values agree with the experimental ones. To further analyze the results, a realistic measurement of the materials provided by the IAEA within different interlaboratory proficiency tests, was performed. The activities obtained using simulated efficiencies were compared to the reference values provided by the organizer. A good agreement in the mid energy section of the spectrum was obtained, while for low energies the lack of some parameters in the simulation libraries proved to produce unacceptable discrepancies. (C) 2015 Elsevier B.V. All rights reserved.",
journal = "Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment",
title = "Application of PHOTON simulation software on calibration of HPGe detectors",
volume = "799",
pages = "159-165",
doi = "10.1016/j.nima.2015.08.002"
}
Krneta-Nikolić, J. D., Puzović, J. M., Todorović, D.,& Rajačić, M.. (2015). Application of PHOTON simulation software on calibration of HPGe detectors. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 799, 159-165.
https://doi.org/10.1016/j.nima.2015.08.002
Krneta-Nikolić JD, Puzović JM, Todorović D, Rajačić M. Application of PHOTON simulation software on calibration of HPGe detectors. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. 2015;799:159-165.
doi:10.1016/j.nima.2015.08.002 .
Krneta-Nikolić, Jelena D., Puzović, Jovan M., Todorović, Dragana, Rajačić, Milica, "Application of PHOTON simulation software on calibration of HPGe detectors" in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 799 (2015):159-165,
https://doi.org/10.1016/j.nima.2015.08.002 . .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB