ВинаР - Репозиторијум Института за нуклеарне науке Винча
    • English
    • Српски
    • Српски (Serbia)
  • Српски (ћирилица) 
    • Енглески
    • Српски (ћирилица)
    • Српски (латиница)
  • Пријава
Преглед записа 
  •   ВинаР
  • Vinča
  • DAIS Import
  • Преглед записа
  •   ВинаР
  • Vinča
  • DAIS Import
  • Преглед записа
JavaScript is disabled for your browser. Some features of this site may not work without it.

Synthetical bone-like and biological hydroxyapatites: a comparative study of crystal structure and morphology

Само за регистроване кориснике
2011
Аутори
Marković, Smilja
Veselinović, Ljiljana M.
Lukić, Miodrag
Karanović, Ljiljana
Bračko, Ines
Ignjatović, Nenad L.
Uskoković, Dragan
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
Phase composition, crystal structure and morphology of biological hydroxyapatite (BHAp) extracted from human mandible bone, and carbonated hydroxyapatite (CHAp), synthesized by the chemical precipitation method, were studied by x-ray powder diffraction (XRD), Fourier transform infrared (FTIR) and Raman (R) spectroscopy techniques, combined with transmission electron microscopy (TEM). Structural and microstructural parameters were determined through Rietveld refinement of recorded XRD data, performed using the FullProf computing program, and TEM. Microstructural analysis shows anisotropic extension along the [0 0 l] crystallographic direction (i.e. elongated crystallites shape) of both investigated samples. The average crystallite sizes of 10 and 8 nm were estimated for BHAp and CHAp, respectively. The FTIR and R spectroscopy studies show that carbonate ions substitute both phosphate and hydroxyl ions in the crystal structure of BHAp as well as in CHAp, indicating that both of them are ...mixed AB-type of CHAp. The thermal behaviour and carbonate content were analysed using thermogravimetric and differential thermal analysis. The carbonate content of about 1 wt.% and phase transition, at near 790 °C, from HAp to β-tricalcium phosphate were determined in both samples. The quality of synthesized CHAp powder, particularly, the particle size distribution and uniformity of morphology, was analysed by a particle size analyser based on laser diffraction and field emission scanning electron microscopy, respectively. These data were used to discuss similarity between natural and synthetic CHAp. Good correlation between the unit cell parameters, average crystallite size, morphology, carbonate content and crystallographic positions of carbonate ions in natural and synthetic HAp samples was found.

Кључне речи:
biological hydroxyapatite / crystal structure / morphology / FTIR / Raman spectroscopy
Извор:
Biomedical Materials, 2011, 6, 4, 045005-
Финансирање / пројекти:
  • Молекуларно дизајнирање наночестица контролисаних морфолошких и физичко-хемијских карактеристика и функционалних материјала на њиховој основи (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-45004)

DOI: 10.1088/1748-6041/6/4/045005

ISSN: 1748-605X

WoS: 000292889900005

Scopus: 2-s2.0-80051950087
[ Google Scholar ]
96
95
URI
https://vinar.vin.bg.ac.rs/handle/123456789/7522
Колекције
  • DAIS Import
Институција/група
Vinča
TY  - JOUR
AU  - Marković, Smilja
AU  - Veselinović, Ljiljana M.
AU  - Lukić, Miodrag
AU  - Karanović, Ljiljana
AU  - Bračko, Ines
AU  - Ignjatović, Nenad L.
AU  - Uskoković, Dragan
PY  - 2011
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7522
AB  - Phase composition, crystal structure and morphology of biological hydroxyapatite (BHAp) extracted from human mandible bone, and carbonated hydroxyapatite (CHAp), synthesized by the chemical precipitation method, were studied by x-ray powder diffraction (XRD), Fourier transform infrared (FTIR) and Raman (R) spectroscopy techniques, combined with transmission electron microscopy (TEM). Structural and microstructural parameters were determined through Rietveld refinement of recorded XRD data, performed using the FullProf computing program, and TEM. Microstructural analysis shows anisotropic extension along the [0 0 l] crystallographic direction (i.e. elongated crystallites shape) of both investigated samples. The average crystallite sizes of 10 and 8 nm were estimated for BHAp and CHAp, respectively. The FTIR and R spectroscopy studies show that carbonate ions substitute both phosphate and hydroxyl ions in the crystal structure of BHAp as well as in CHAp, indicating that both of them are mixed AB-type of CHAp. The thermal behaviour and carbonate content were analysed using thermogravimetric and differential thermal analysis. The carbonate content of about 1 wt.% and phase transition, at near 790 °C, from HAp to β-tricalcium phosphate were determined in both samples. The quality of synthesized CHAp powder, particularly, the particle size distribution and uniformity of morphology, was analysed by a particle size analyser based on laser diffraction and field emission scanning electron microscopy, respectively. These data were used to discuss similarity between natural and synthetic CHAp. Good correlation between the unit cell parameters, average crystallite size, morphology, carbonate content and crystallographic positions of carbonate ions in natural and synthetic HAp samples was found.
T2  - Biomedical Materials
T1  - Synthetical bone-like and biological hydroxyapatites: a comparative study of crystal structure and morphology
VL  - 6
IS  - 4
SP  - 045005
DO  - 10.1088/1748-6041/6/4/045005
ER  - 
@article{
author = "Marković, Smilja and Veselinović, Ljiljana M. and Lukić, Miodrag and Karanović, Ljiljana and Bračko, Ines and Ignjatović, Nenad L. and Uskoković, Dragan",
year = "2011",
abstract = "Phase composition, crystal structure and morphology of biological hydroxyapatite (BHAp) extracted from human mandible bone, and carbonated hydroxyapatite (CHAp), synthesized by the chemical precipitation method, were studied by x-ray powder diffraction (XRD), Fourier transform infrared (FTIR) and Raman (R) spectroscopy techniques, combined with transmission electron microscopy (TEM). Structural and microstructural parameters were determined through Rietveld refinement of recorded XRD data, performed using the FullProf computing program, and TEM. Microstructural analysis shows anisotropic extension along the [0 0 l] crystallographic direction (i.e. elongated crystallites shape) of both investigated samples. The average crystallite sizes of 10 and 8 nm were estimated for BHAp and CHAp, respectively. The FTIR and R spectroscopy studies show that carbonate ions substitute both phosphate and hydroxyl ions in the crystal structure of BHAp as well as in CHAp, indicating that both of them are mixed AB-type of CHAp. The thermal behaviour and carbonate content were analysed using thermogravimetric and differential thermal analysis. The carbonate content of about 1 wt.% and phase transition, at near 790 °C, from HAp to β-tricalcium phosphate were determined in both samples. The quality of synthesized CHAp powder, particularly, the particle size distribution and uniformity of morphology, was analysed by a particle size analyser based on laser diffraction and field emission scanning electron microscopy, respectively. These data were used to discuss similarity between natural and synthetic CHAp. Good correlation between the unit cell parameters, average crystallite size, morphology, carbonate content and crystallographic positions of carbonate ions in natural and synthetic HAp samples was found.",
journal = "Biomedical Materials",
title = "Synthetical bone-like and biological hydroxyapatites: a comparative study of crystal structure and morphology",
volume = "6",
number = "4",
pages = "045005",
doi = "10.1088/1748-6041/6/4/045005"
}
Marković, S., Veselinović, L. M., Lukić, M., Karanović, L., Bračko, I., Ignjatović, N. L.,& Uskoković, D.. (2011). Synthetical bone-like and biological hydroxyapatites: a comparative study of crystal structure and morphology. in Biomedical Materials, 6(4), 045005.
https://doi.org/10.1088/1748-6041/6/4/045005
Marković S, Veselinović LM, Lukić M, Karanović L, Bračko I, Ignjatović NL, Uskoković D. Synthetical bone-like and biological hydroxyapatites: a comparative study of crystal structure and morphology. in Biomedical Materials. 2011;6(4):045005.
doi:10.1088/1748-6041/6/4/045005 .
Marković, Smilja, Veselinović, Ljiljana M., Lukić, Miodrag, Karanović, Ljiljana, Bračko, Ines, Ignjatović, Nenad L., Uskoković, Dragan, "Synthetical bone-like and biological hydroxyapatites: a comparative study of crystal structure and morphology" in Biomedical Materials, 6, no. 4 (2011):045005,
https://doi.org/10.1088/1748-6041/6/4/045005 . .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB