Приказ основних података о документу

dc.creatorRafajlović, Stefan
dc.creatorAranđić, Danijela
dc.creatorBožović, Predrag
dc.creatorĆeklić, Sandra
dc.creatorLazarević, Đorđe R.
dc.creatorCiraj-Bjelac, Olivera
dc.date.accessioned2018-03-03T15:06:27Z
dc.date.available2018-03-03T15:06:27Z
dc.date.issued2016
dc.identifier.issn2466-4626
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/7167
dc.description.abstractThe purpose of this study is to investigate the radiation dose and technical image quality in mammography in Serbia after two years of implementation of the breast screening programme. A total of 186 mammography units, including Full-Field Digital Mammography (FFDM), Computed Radiography (CR) and Screen-Film Mammography (SFM) units were used in the patient dose and image quality assessment. Patient dose, in terms of Mean Glandular Dose (MGD), was assessed for the standard breast, while image quality was evaluated in terms of spatial resolution, threshold contrast visibility and Contrast to Noise Ratio (CNR) for CR and FFDM units. The mean MGD assessed was (1.8 +/- 0.94) mGy, (1.3 +/- 0.51) and (1.7 +/- 0.64) for CR, FFDM and SFM, respectively. Spatial resolution was better than 12 lp/mm only for 3/186 (1.6%) units. In 34/186 (1896) units, spatial resolution was less than 5 lp/mm. Threshold contrast visibility was better than 1.2 in 41/186 (22%). Mean CNR for CR and FFDM units was 5.2 2.2. Following the initial implementation at the beginning of the population-based breast cancer screening campaign, it is essential to establish an effective system of regular and periodic Quality Control (QC) tests and to ensure that high-quality mammograms with minimal possible radiation dose to population are included in the screening.en
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/43009/RS//
dc.rightsopenAccessen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceRAD Conference Proceedings
dc.subjectMammographyen
dc.subjectimage qualityen
dc.subjectradiation doseen
dc.titleMammography in Serbia: Image Quality and Radiation Doseen
dc.typeconferenceObjecten
dc.rights.licenseBY
dcterms.abstractAрандјиц, Данијела; Лазаревиц, Дјордје; Цеклиц, Сандра; Цирај-Бјелац Оливера; Рафајловиц, Стефан; Божовић Предраг;
dc.citation.spage29
dc.citation.epage32
dc.identifier.wos000403671400008
dc.identifier.doi10.21175/RadProc.2016.08
dc.description.other4th International Conference on Radiation and Applications in Various Fields of Research (RAD), Proceedings, May 23-27, 2016, Nis, Serbiaen
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85058032071
dc.identifier.fulltexthttps://vinar.vin.bg.ac.rs/bitstream/id/22216/RadProc.2016.08.pdf


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу