Commissioning and Performance of the CMS Pixel Tracker with Cosmic Ray Muons
![](/themes/MirageVinar//images/openAccess.png)
2010
Authors
Chatrchyan, S.Adžić, Petar
Đorđević, Miloš
![](/themes/MirageVinar/images/orcid.png)
Jovanović, Dragana J.
![](/themes/MirageVinar/images/orcid.png)
Krpić, D.
Maletić, Dimitrije
Puzović, Jovan M.
Smiljković, Nikola
Milenović, Predrag
![](/themes/MirageVinar/images/orcid.png)
Reković, Vladimir
![](/themes/MirageVinar/images/orcid.png)
CMS Collaboration (ukupan broj autora: 2424)
Article
Metadata
Show full item recordAbstract
The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.
Source:
Journal of Instrumentation, 2010, 5Funding / projects:
- FMSR (Austria), FNRS (Belgium), FWO (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN, CAS (China), MoST (China), NSFC (China), COLCIEN-CIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences (Estonia), NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain), CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation
DOI: 10.1088/1748-0221/5/03/T03007
ISSN: 1748-0221
WoS: 000286973300002
Scopus: 2-s2.0-80052268825
Collections
Institution/Community
VinčaTY - JOUR AU - Chatrchyan, S. AU - Adžić, Petar AU - Đorđević, Miloš AU - Jovanović, Dragana J. AU - Krpić, D. AU - Maletić, Dimitrije AU - Puzović, Jovan M. AU - Smiljković, Nikola AU - Milenović, Predrag AU - Reković, Vladimir PY - 2010 UR - https://vinar.vin.bg.ac.rs/handle/123456789/4213 AB - The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns. T2 - Journal of Instrumentation T1 - Commissioning and Performance of the CMS Pixel Tracker with Cosmic Ray Muons VL - 5 DO - 10.1088/1748-0221/5/03/T03007 ER -
@article{ author = "Chatrchyan, S. and Adžić, Petar and Đorđević, Miloš and Jovanović, Dragana J. and Krpić, D. and Maletić, Dimitrije and Puzović, Jovan M. and Smiljković, Nikola and Milenović, Predrag and Reković, Vladimir", year = "2010", abstract = "The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.", journal = "Journal of Instrumentation", title = "Commissioning and Performance of the CMS Pixel Tracker with Cosmic Ray Muons", volume = "5", doi = "10.1088/1748-0221/5/03/T03007" }
Chatrchyan, S., Adžić, P., Đorđević, M., Jovanović, D. J., Krpić, D., Maletić, D., Puzović, J. M., Smiljković, N., Milenović, P.,& Reković, V.. (2010). Commissioning and Performance of the CMS Pixel Tracker with Cosmic Ray Muons. in Journal of Instrumentation, 5. https://doi.org/10.1088/1748-0221/5/03/T03007
Chatrchyan S, Adžić P, Đorđević M, Jovanović DJ, Krpić D, Maletić D, Puzović JM, Smiljković N, Milenović P, Reković V. Commissioning and Performance of the CMS Pixel Tracker with Cosmic Ray Muons. in Journal of Instrumentation. 2010;5. doi:10.1088/1748-0221/5/03/T03007 .
Chatrchyan, S., Adžić, Petar, Đorđević, Miloš, Jovanović, Dragana J., Krpić, D., Maletić, Dimitrije, Puzović, Jovan M., Smiljković, Nikola, Milenović, Predrag, Reković, Vladimir, "Commissioning and Performance of the CMS Pixel Tracker with Cosmic Ray Muons" in Journal of Instrumentation, 5 (2010), https://doi.org/10.1088/1748-0221/5/03/T03007 . .