Measurement of the muon stopping power in lead tungstate
2010
Аутори
Chatrchyan, S.Adžić, Petar
Đorđević, Miloš
Jovanović, Dragana J.
Krpić, D.
Maletić, Dimitrije
Puzović, Jovan M.
Smiljković, Nikola
Milenović, Predrag
(ukupan broj autora: 2422)
Чланак у часопису
Метаподаци
Приказ свих података о документуАпстракт
A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160(-6)(+5) +/- 8 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy.
Кључне речи:
Interaction of radiation with matter / CalorimetersИзвор:
Journal of Instrumentation, 2010, 5Финансирање / пројекти:
- FMSR (Austria), FNRS (Belgium), FWO (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN (China), CAS (China), MoST (China), NSFC (China), COLCIEN-CIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences (Estonia), NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain), CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation
DOI: 10.1088/1748-0221/5/03/P03007
ISSN: 1748-0221
WoS: 000280524100022
Scopus: 2-s2.0-79953271786
Колекције
Институција/група
VinčaTY - JOUR AU - Chatrchyan, S. AU - Adžić, Petar AU - Đorđević, Miloš AU - Jovanović, Dragana J. AU - Krpić, D. AU - Maletić, Dimitrije AU - Puzović, Jovan M. AU - Smiljković, Nikola AU - Milenović, Predrag PY - 2010 UR - https://vinar.vin.bg.ac.rs/handle/123456789/3955 AB - A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160(-6)(+5) +/- 8 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. T2 - Journal of Instrumentation T1 - Measurement of the muon stopping power in lead tungstate VL - 5 DO - 10.1088/1748-0221/5/03/P03007 ER -
@article{ author = "Chatrchyan, S. and Adžić, Petar and Đorđević, Miloš and Jovanović, Dragana J. and Krpić, D. and Maletić, Dimitrije and Puzović, Jovan M. and Smiljković, Nikola and Milenović, Predrag", year = "2010", abstract = "A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160(-6)(+5) +/- 8 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy.", journal = "Journal of Instrumentation", title = "Measurement of the muon stopping power in lead tungstate", volume = "5", doi = "10.1088/1748-0221/5/03/P03007" }
Chatrchyan, S., Adžić, P., Đorđević, M., Jovanović, D. J., Krpić, D., Maletić, D., Puzović, J. M., Smiljković, N.,& Milenović, P.. (2010). Measurement of the muon stopping power in lead tungstate. in Journal of Instrumentation, 5. https://doi.org/10.1088/1748-0221/5/03/P03007
Chatrchyan S, Adžić P, Đorđević M, Jovanović DJ, Krpić D, Maletić D, Puzović JM, Smiljković N, Milenović P. Measurement of the muon stopping power in lead tungstate. in Journal of Instrumentation. 2010;5. doi:10.1088/1748-0221/5/03/P03007 .
Chatrchyan, S., Adžić, Petar, Đorđević, Miloš, Jovanović, Dragana J., Krpić, D., Maletić, Dimitrije, Puzović, Jovan M., Smiljković, Nikola, Milenović, Predrag, "Measurement of the muon stopping power in lead tungstate" in Journal of Instrumentation, 5 (2010), https://doi.org/10.1088/1748-0221/5/03/P03007 . .