Time reconstruction and performance of the CMS electromagnetic calorimeter
2010
Аутори
Chatrchyan, S.Adžić, Petar
Đorđević, Miloš
Jovanović, Dragana J.
Krpić, D.
Maletić, Dimitrije
Puzović, Jovan M.
Smiljković, Nikola
Milenović, Predrag
(ukupan broj autora: 2423)
Чланак у часопису
Метаподаци
Приказ свих података о документуАпстракт
The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008.
Кључне речи:
Calorimeters / Large detector systems for particle and astroparticle physicsИзвор:
Journal of Instrumentation, 2010, 5Финансирање / пројекти:
- FMSR (Austria), FNRS (Belgium), FWO (Belgium), CNPq (Brazil), CAPES (Brazil), FAPERJ (Brazil), FAPESP (Brazil), MES (Bulgaria), CERN (China), CAS (China), MoST (China), NSFC (China), COLCIEN-CIAS (Colombia), MSES (Croatia), RPF (Cyprus), Academy of Sciences (Estonia), NICPB (Estonia), Academy of Finland, ME (Finland), HIP (Finland), CEA (France), CNRS/IN2P3 (France), BMBF, Germany, DFG (Germany), HGF (Germany), GSRT (Greece), OTKA (Hungary), NKTH (Hungary), DAE (India), DST (India), IPM (Iran), SFI (Ireland), INFN (Italy), NRF (Korea), LAS (Lithuania), CINVESTAV (Mexico), CONACYT (Mexico), SEP (Mexico), UASLP-FAI (Mexico), PAEC (Pakistan), SCSR (Poland), FCT (Portugal), JINR (Armenia), JINR (Belarus), JINR (Georgia), JINR (Ukraine), JINR (Uzbekistan), MST (Russia), MAE (Russia), MSTDS (Serbia), MICINN (Spain), CPAN (Spain), Swiss Funding Agencies (Switzerland), NSC (Taipei), TUBITAK (Turkey), TAEK (Turkey), STFC (United Kingdom), DOE (USA), NSF (USA), European Union, Leventis Foundation, A.P. Sloan Foundation, Alexander von Humboldt Foundation
DOI: 10.1088/1748-0221/5/03/T03011
ISSN: 1748-0221
WoS: 000280524100021
Scopus: 2-s2.0-78649702159
Колекције
Институција/група
VinčaTY - JOUR AU - Chatrchyan, S. AU - Adžić, Petar AU - Đorđević, Miloš AU - Jovanović, Dragana J. AU - Krpić, D. AU - Maletić, Dimitrije AU - Puzović, Jovan M. AU - Smiljković, Nikola AU - Milenović, Predrag PY - 2010 UR - https://vinar.vin.bg.ac.rs/handle/123456789/3954 AB - The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. T2 - Journal of Instrumentation T1 - Time reconstruction and performance of the CMS electromagnetic calorimeter VL - 5 DO - 10.1088/1748-0221/5/03/T03011 ER -
@article{ author = "Chatrchyan, S. and Adžić, Petar and Đorđević, Miloš and Jovanović, Dragana J. and Krpić, D. and Maletić, Dimitrije and Puzović, Jovan M. and Smiljković, Nikola and Milenović, Predrag", year = "2010", abstract = "The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008.", journal = "Journal of Instrumentation", title = "Time reconstruction and performance of the CMS electromagnetic calorimeter", volume = "5", doi = "10.1088/1748-0221/5/03/T03011" }
Chatrchyan, S., Adžić, P., Đorđević, M., Jovanović, D. J., Krpić, D., Maletić, D., Puzović, J. M., Smiljković, N.,& Milenović, P.. (2010). Time reconstruction and performance of the CMS electromagnetic calorimeter. in Journal of Instrumentation, 5. https://doi.org/10.1088/1748-0221/5/03/T03011
Chatrchyan S, Adžić P, Đorđević M, Jovanović DJ, Krpić D, Maletić D, Puzović JM, Smiljković N, Milenović P. Time reconstruction and performance of the CMS electromagnetic calorimeter. in Journal of Instrumentation. 2010;5. doi:10.1088/1748-0221/5/03/T03011 .
Chatrchyan, S., Adžić, Petar, Đorđević, Miloš, Jovanović, Dragana J., Krpić, D., Maletić, Dimitrije, Puzović, Jovan M., Smiljković, Nikola, Milenović, Predrag, "Time reconstruction and performance of the CMS electromagnetic calorimeter" in Journal of Instrumentation, 5 (2010), https://doi.org/10.1088/1748-0221/5/03/T03011 . .