Detection of muons at 150 GeV/c with a CMS Preshower prototype
Nema prikaza
Autori
Barney, D.Bialas, W.
Kokkas, P.
Manthos, N.
Maletić, Dimitrije
Papadopoulos, I.
Peisert, A.
Reynaud, S.
Vichoudis, P.
Članak u časopisu
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
The analysis of 150 GeV/c muon data collected during a test of a CMS Preshower prototype is presented. The test took place in 2004 in the H4 beam at CERN. The muon signal extraction is possible after pedestal subtraction and common mode correction. The results of a Geant-4-based simulation, developed for the Preshower prototype test, are also presented. The results of the simulation are found to be in excellent agreement with the data. It is also demonstrated that by combining the results of the data analysis and simulation an absolute calibration of the CMS Preshower detector system can be performed. (c) 2006 Elsevier B.V. All rights reserved.
Ključne reči:
CMS / preshower / test beam muon data analysis / detector calibrationIzvor:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 2006, 564, 1, 126-133
DOI: 10.1016/j.nima.2006.03.031
ISSN: 0168-9002; 1872-9576
WoS: 000239669500017
Scopus: 2-s2.0-33745899911
Kolekcije
Institucija/grupa
VinčaTY - JOUR AU - Barney, D. AU - Bialas, W. AU - Kokkas, P. AU - Manthos, N. AU - Maletić, Dimitrije AU - Papadopoulos, I. AU - Peisert, A. AU - Reynaud, S. AU - Vichoudis, P. PY - 2006 UR - https://vinar.vin.bg.ac.rs/handle/123456789/3060 AB - The analysis of 150 GeV/c muon data collected during a test of a CMS Preshower prototype is presented. The test took place in 2004 in the H4 beam at CERN. The muon signal extraction is possible after pedestal subtraction and common mode correction. The results of a Geant-4-based simulation, developed for the Preshower prototype test, are also presented. The results of the simulation are found to be in excellent agreement with the data. It is also demonstrated that by combining the results of the data analysis and simulation an absolute calibration of the CMS Preshower detector system can be performed. (c) 2006 Elsevier B.V. All rights reserved. T2 - Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment T1 - Detection of muons at 150 GeV/c with a CMS Preshower prototype VL - 564 IS - 1 SP - 126 EP - 133 DO - 10.1016/j.nima.2006.03.031 ER -
@article{ author = "Barney, D. and Bialas, W. and Kokkas, P. and Manthos, N. and Maletić, Dimitrije and Papadopoulos, I. and Peisert, A. and Reynaud, S. and Vichoudis, P.", year = "2006", abstract = "The analysis of 150 GeV/c muon data collected during a test of a CMS Preshower prototype is presented. The test took place in 2004 in the H4 beam at CERN. The muon signal extraction is possible after pedestal subtraction and common mode correction. The results of a Geant-4-based simulation, developed for the Preshower prototype test, are also presented. The results of the simulation are found to be in excellent agreement with the data. It is also demonstrated that by combining the results of the data analysis and simulation an absolute calibration of the CMS Preshower detector system can be performed. (c) 2006 Elsevier B.V. All rights reserved.", journal = "Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment", title = "Detection of muons at 150 GeV/c with a CMS Preshower prototype", volume = "564", number = "1", pages = "126-133", doi = "10.1016/j.nima.2006.03.031" }
Barney, D., Bialas, W., Kokkas, P., Manthos, N., Maletić, D., Papadopoulos, I., Peisert, A., Reynaud, S.,& Vichoudis, P.. (2006). Detection of muons at 150 GeV/c with a CMS Preshower prototype. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 564(1), 126-133. https://doi.org/10.1016/j.nima.2006.03.031
Barney D, Bialas W, Kokkas P, Manthos N, Maletić D, Papadopoulos I, Peisert A, Reynaud S, Vichoudis P. Detection of muons at 150 GeV/c with a CMS Preshower prototype. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. 2006;564(1):126-133. doi:10.1016/j.nima.2006.03.031 .
Barney, D., Bialas, W., Kokkas, P., Manthos, N., Maletić, Dimitrije, Papadopoulos, I., Peisert, A., Reynaud, S., Vichoudis, P., "Detection of muons at 150 GeV/c with a CMS Preshower prototype" in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 564, no. 1 (2006):126-133, https://doi.org/10.1016/j.nima.2006.03.031 . .