Performance of the CMS ECAL safety system for super modules SM0 and SM1
Нема приказа
Аутори
Milenović, PredragPuzović, Jovan M.
Jovanovic, D
Maletić, Dimitrije
Dissertori, G
Adžić, Petar
Чланак у часопису
Метаподаци
Приказ свих података о документуАпстракт
A prototype of the safety system for the electromagnetic calorimeter (ECAL) of the CMS detector at LHC has been implemented and tested in Super Modules SM0 and SM1 during the ECAL test-beam campaign in summer 2003. The aim was to examine the system performance thoroughly and to resolve several open issues regarding the final system design. The performed tests mainly focused on the readout System performance, its calibration and noise problems. Furthermore, irradiation tests of the readout electronics components with a 64 MeV proton beam Lip to an equivalent cumulative dose of 200 kGy and 3.2 x 10(14) neutron cm(-2) have been performed at the Paul Scherrer Institute in spring 2004. The results of all these tests are very promising, leading to the conclusion that the tested prototype offers an excellent basis for the development of the safety system for the entire CMS ECAL. (c) 2005 Elsevier B.V. All rights reserved.
Кључне речи:
detector control / LHC / CMS / electromagnetic calorimetryИзвор:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 2005, 554, 1-3, 427-436
DOI: 10.1016/j.nima.2005.08.028
ISSN: 0168-9002
WoS: 000233978500038
Scopus: 2-s2.0-27844444094
Колекције
Институција/група
VinčaTY - JOUR AU - Milenović, Predrag AU - Puzović, Jovan M. AU - Jovanovic, D AU - Maletić, Dimitrije AU - Dissertori, G AU - Adžić, Petar PY - 2005 UR - https://vinar.vin.bg.ac.rs/handle/123456789/2953 AB - A prototype of the safety system for the electromagnetic calorimeter (ECAL) of the CMS detector at LHC has been implemented and tested in Super Modules SM0 and SM1 during the ECAL test-beam campaign in summer 2003. The aim was to examine the system performance thoroughly and to resolve several open issues regarding the final system design. The performed tests mainly focused on the readout System performance, its calibration and noise problems. Furthermore, irradiation tests of the readout electronics components with a 64 MeV proton beam Lip to an equivalent cumulative dose of 200 kGy and 3.2 x 10(14) neutron cm(-2) have been performed at the Paul Scherrer Institute in spring 2004. The results of all these tests are very promising, leading to the conclusion that the tested prototype offers an excellent basis for the development of the safety system for the entire CMS ECAL. (c) 2005 Elsevier B.V. All rights reserved. T2 - Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment T1 - Performance of the CMS ECAL safety system for super modules SM0 and SM1 VL - 554 IS - 1-3 SP - 427 EP - 436 DO - 10.1016/j.nima.2005.08.028 ER -
@article{ author = "Milenović, Predrag and Puzović, Jovan M. and Jovanovic, D and Maletić, Dimitrije and Dissertori, G and Adžić, Petar", year = "2005", abstract = "A prototype of the safety system for the electromagnetic calorimeter (ECAL) of the CMS detector at LHC has been implemented and tested in Super Modules SM0 and SM1 during the ECAL test-beam campaign in summer 2003. The aim was to examine the system performance thoroughly and to resolve several open issues regarding the final system design. The performed tests mainly focused on the readout System performance, its calibration and noise problems. Furthermore, irradiation tests of the readout electronics components with a 64 MeV proton beam Lip to an equivalent cumulative dose of 200 kGy and 3.2 x 10(14) neutron cm(-2) have been performed at the Paul Scherrer Institute in spring 2004. The results of all these tests are very promising, leading to the conclusion that the tested prototype offers an excellent basis for the development of the safety system for the entire CMS ECAL. (c) 2005 Elsevier B.V. All rights reserved.", journal = "Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment", title = "Performance of the CMS ECAL safety system for super modules SM0 and SM1", volume = "554", number = "1-3", pages = "427-436", doi = "10.1016/j.nima.2005.08.028" }
Milenović, P., Puzović, J. M., Jovanovic, D., Maletić, D., Dissertori, G.,& Adžić, P.. (2005). Performance of the CMS ECAL safety system for super modules SM0 and SM1. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 554(1-3), 427-436. https://doi.org/10.1016/j.nima.2005.08.028
Milenović P, Puzović JM, Jovanovic D, Maletić D, Dissertori G, Adžić P. Performance of the CMS ECAL safety system for super modules SM0 and SM1. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. 2005;554(1-3):427-436. doi:10.1016/j.nima.2005.08.028 .
Milenović, Predrag, Puzović, Jovan M., Jovanovic, D, Maletić, Dimitrije, Dissertori, G, Adžić, Petar, "Performance of the CMS ECAL safety system for super modules SM0 and SM1" in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 554, no. 1-3 (2005):427-436, https://doi.org/10.1016/j.nima.2005.08.028 . .