Emission spectrometric analysis of fresh waters with U-shaped dc arc with aerosol supply
Апстракт
The application of a U-shaped d.c. are with aerosol supply for analysis of fresh waters has been described. Limits of detection obtained with d.c. plasma compare well with those reported for ICP. A number of spectral lines and molecular bands were examined and the most suitable are selected to ensure the best limits of detection or wide dynamic ranges. Limits of detection in ng ml(-1), given in the parenthesis, following the element symbol, are: Al(0.9), B(0.6), Ba(0.2), Be(0.15), Ca(0.05), Cd(3.5), Co(1.1), Cr(0.2), Fe(2.4), Ga(0.5), Hg(9.0), K(0.3), Li(0.008), Mg(0.4), Mn(0.3), Mo(0.7), Na(0.04), Ni(2.0), P(45), Pb(12), Si(9.0), Sr(0.04), Zn(1.3).
Кључне речи:
dc arc / emission spectroscopy / water analysisИзвор:
Spectroscopy Letters, 1996, 29, 2, 205-215
DOI: 10.1080/00387019608001597
ISSN: 0038-7010
WoS: A1996TZ29800002
Scopus: 2-s2.0-0013164198
Колекције
Институција/група
VinčaTY - JOUR AU - Kuzmanović, Miroslav M. AU - Pavlović, Mirjana S. AU - Marinković, Miloš PY - 1996 UR - https://vinar.vin.bg.ac.rs/handle/123456789/1965 AB - The application of a U-shaped d.c. are with aerosol supply for analysis of fresh waters has been described. Limits of detection obtained with d.c. plasma compare well with those reported for ICP. A number of spectral lines and molecular bands were examined and the most suitable are selected to ensure the best limits of detection or wide dynamic ranges. Limits of detection in ng ml(-1), given in the parenthesis, following the element symbol, are: Al(0.9), B(0.6), Ba(0.2), Be(0.15), Ca(0.05), Cd(3.5), Co(1.1), Cr(0.2), Fe(2.4), Ga(0.5), Hg(9.0), K(0.3), Li(0.008), Mg(0.4), Mn(0.3), Mo(0.7), Na(0.04), Ni(2.0), P(45), Pb(12), Si(9.0), Sr(0.04), Zn(1.3). T2 - Spectroscopy Letters T1 - Emission spectrometric analysis of fresh waters with U-shaped dc arc with aerosol supply VL - 29 IS - 2 SP - 205 EP - 215 DO - 10.1080/00387019608001597 ER -
@article{ author = "Kuzmanović, Miroslav M. and Pavlović, Mirjana S. and Marinković, Miloš", year = "1996", abstract = "The application of a U-shaped d.c. are with aerosol supply for analysis of fresh waters has been described. Limits of detection obtained with d.c. plasma compare well with those reported for ICP. A number of spectral lines and molecular bands were examined and the most suitable are selected to ensure the best limits of detection or wide dynamic ranges. Limits of detection in ng ml(-1), given in the parenthesis, following the element symbol, are: Al(0.9), B(0.6), Ba(0.2), Be(0.15), Ca(0.05), Cd(3.5), Co(1.1), Cr(0.2), Fe(2.4), Ga(0.5), Hg(9.0), K(0.3), Li(0.008), Mg(0.4), Mn(0.3), Mo(0.7), Na(0.04), Ni(2.0), P(45), Pb(12), Si(9.0), Sr(0.04), Zn(1.3).", journal = "Spectroscopy Letters", title = "Emission spectrometric analysis of fresh waters with U-shaped dc arc with aerosol supply", volume = "29", number = "2", pages = "205-215", doi = "10.1080/00387019608001597" }
Kuzmanović, M. M., Pavlović, M. S.,& Marinković, M.. (1996). Emission spectrometric analysis of fresh waters with U-shaped dc arc with aerosol supply. in Spectroscopy Letters, 29(2), 205-215. https://doi.org/10.1080/00387019608001597
Kuzmanović MM, Pavlović MS, Marinković M. Emission spectrometric analysis of fresh waters with U-shaped dc arc with aerosol supply. in Spectroscopy Letters. 1996;29(2):205-215. doi:10.1080/00387019608001597 .
Kuzmanović, Miroslav M., Pavlović, Mirjana S., Marinković, Miloš, "Emission spectrometric analysis of fresh waters with U-shaped dc arc with aerosol supply" in Spectroscopy Letters, 29, no. 2 (1996):205-215, https://doi.org/10.1080/00387019608001597 . .