Measurement of Cosmic Radiation Exposure of Aircraft Crew At Commercial Aviation Altitudes
Authors
Vujičić, Vladimir M.Simović, David R.
Staletović, Novica M.
Zečević, Milija
Bogojević, Suzana A.
Lazarević, Đorđe R.
Article (Published version)
Metadata
Show full item recordAbstract
The measurement results of ambient dose equivalent rate in an aircraft, performed by a standard portable dosimeter, at a non-commercial flight Belgrade - Podgorica at altitudes up to 9000 meters, are shown. By numerical interpolation of the measurement results, a functional dependency of the ambient dose equivalent rate on the altitude of the airplane flight is determined, obtaining a good agreement with the reference values. For commercial airlines in the Balkan region, total ambient dose equivalent, regarding the aircraft crew occupationally exposed to radiation in the course of a flight, was calculated and the maximum permitted number of flight hours per year, was estimated.
Keywords:
cosmic radiation / ambient dose equivalent rate / portable dosimeter / aircraft crew / Balcan regionSource:
Nuclear technology and radiation protection, 2017, 32, 1, 52-56Funding / projects:
- Physical and functional effects of radiation interaction with electrotechnical and biological systems (RS-MESTD-Basic Research (BR or ON)-171007)
DOI: 10.2298/NTRP1701052V
ISSN: 1451-3994
WoS: 000403628500007
Scopus: 2-s2.0-85020715687
Collections
Institution/Community
VinčaTY - JOUR AU - Vujičić, Vladimir M. AU - Simović, David R. AU - Staletović, Novica M. AU - Zečević, Milija AU - Bogojević, Suzana A. AU - Lazarević, Đorđe R. PY - 2017 UR - https://vinar.vin.bg.ac.rs/handle/123456789/1605 AB - The measurement results of ambient dose equivalent rate in an aircraft, performed by a standard portable dosimeter, at a non-commercial flight Belgrade - Podgorica at altitudes up to 9000 meters, are shown. By numerical interpolation of the measurement results, a functional dependency of the ambient dose equivalent rate on the altitude of the airplane flight is determined, obtaining a good agreement with the reference values. For commercial airlines in the Balkan region, total ambient dose equivalent, regarding the aircraft crew occupationally exposed to radiation in the course of a flight, was calculated and the maximum permitted number of flight hours per year, was estimated. T2 - Nuclear technology and radiation protection T1 - Measurement of Cosmic Radiation Exposure of Aircraft Crew At Commercial Aviation Altitudes VL - 32 IS - 1 SP - 52 EP - 56 DO - 10.2298/NTRP1701052V ER -
@article{ author = "Vujičić, Vladimir M. and Simović, David R. and Staletović, Novica M. and Zečević, Milija and Bogojević, Suzana A. and Lazarević, Đorđe R.", year = "2017", abstract = "The measurement results of ambient dose equivalent rate in an aircraft, performed by a standard portable dosimeter, at a non-commercial flight Belgrade - Podgorica at altitudes up to 9000 meters, are shown. By numerical interpolation of the measurement results, a functional dependency of the ambient dose equivalent rate on the altitude of the airplane flight is determined, obtaining a good agreement with the reference values. For commercial airlines in the Balkan region, total ambient dose equivalent, regarding the aircraft crew occupationally exposed to radiation in the course of a flight, was calculated and the maximum permitted number of flight hours per year, was estimated.", journal = "Nuclear technology and radiation protection", title = "Measurement of Cosmic Radiation Exposure of Aircraft Crew At Commercial Aviation Altitudes", volume = "32", number = "1", pages = "52-56", doi = "10.2298/NTRP1701052V" }
Vujičić, V. M., Simović, D. R., Staletović, N. M., Zečević, M., Bogojević, S. A.,& Lazarević, Đ. R.. (2017). Measurement of Cosmic Radiation Exposure of Aircraft Crew At Commercial Aviation Altitudes. in Nuclear technology and radiation protection, 32(1), 52-56. https://doi.org/10.2298/NTRP1701052V
Vujičić VM, Simović DR, Staletović NM, Zečević M, Bogojević SA, Lazarević ĐR. Measurement of Cosmic Radiation Exposure of Aircraft Crew At Commercial Aviation Altitudes. in Nuclear technology and radiation protection. 2017;32(1):52-56. doi:10.2298/NTRP1701052V .
Vujičić, Vladimir M., Simović, David R., Staletović, Novica M., Zečević, Milija, Bogojević, Suzana A., Lazarević, Đorđe R., "Measurement of Cosmic Radiation Exposure of Aircraft Crew At Commercial Aviation Altitudes" in Nuclear technology and radiation protection, 32, no. 1 (2017):52-56, https://doi.org/10.2298/NTRP1701052V . .