Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout
Abstract
Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.
Keywords:
Scintillator / WLS fiber / SiPM / MPPC / Time resolution / Position resolutionSource:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 2017, 848, 54-59Funding / projects:
- Physics and Detector R&D in HEP Experiments (RS-MESTD-Basic Research (BR or ON)-171012)
- Nuclear physics, methods and application (RS-MESTD-Basic Research (BR or ON)-171018)
- Ministry of Education and Science, National Research Center Kurchatov Institute (Russian Federation), Department of Energy (United States of America)
DOI: 10.1016/j.nima.2016.12.043
ISSN: 0168-9002; 1872-9576
WoS: 000394627600007
Scopus: 2-s2.0-85007579742
Collections
Institution/Community
VinčaTY - JOUR AU - Denisov, Dmitri AU - Evdokimov, Valery AU - Lukić, Strahinja AU - Ujić, Predrag PY - 2017 UR - https://vinar.vin.bg.ac.rs/handle/123456789/1434 AB - Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm. T2 - Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment T1 - Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout VL - 848 SP - 54 EP - 59 DO - 10.1016/j.nima.2016.12.043 ER -
@article{ author = "Denisov, Dmitri and Evdokimov, Valery and Lukić, Strahinja and Ujić, Predrag", year = "2017", abstract = "Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.", journal = "Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment", title = "Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout", volume = "848", pages = "54-59", doi = "10.1016/j.nima.2016.12.043" }
Denisov, D., Evdokimov, V., Lukić, S.,& Ujić, P.. (2017). Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 848, 54-59. https://doi.org/10.1016/j.nima.2016.12.043
Denisov D, Evdokimov V, Lukić S, Ujić P. Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout. in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. 2017;848:54-59. doi:10.1016/j.nima.2016.12.043 .
Denisov, Dmitri, Evdokimov, Valery, Lukić, Strahinja, Ujić, Predrag, "Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout" in Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 848 (2017):54-59, https://doi.org/10.1016/j.nima.2016.12.043 . .