Systematic uncertainties in integrated luminosity measurement at CEPC

Thumbnail
2023
Преузимање 🢃
Conference article [PDF] (2.017Mb)
Аутори
Smiljanić, Ivan
Božović-Jelisavčić, Ivanka
Kačarević, Goran
Vukašinović, Nataša
Vidaković, Ivana
Reković, Vladimir
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
The very forward region is one of the most challenging regions to instrument at a future e+e− collider. Machine-detector interface at CEPC will include a calorimeter dedicated for precision measurement of the integrated luminosity at a permill level or better. We discuss a feasibility of such precision from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background. Additionally, a method of the beam energy spread determination, initially proposed for FCC, is discussed for the CEPC beams, as well as the impact of beam energy spread uncertainty on integrated luminosity measurement and the precision of electroweak observables determination at the Z0 pole.
Извор:
Proceedings of Science, 2023, 427, 193246-
Финансирање / пројекти:
  • 2023-07-17 HIGHTONE-P - HIGGS boson: A portal to new physics (RS-ScienceFundRS-Ideje-7699827)
Напомена:
  • BPU11 : 11th International Conference of the Balkan Physical Union
  • S05-HEP High Energy Physics (Particles and Fields)

DOI: 10.22323/1.427.0086

ISSN: 1824-8039

Scopus: 2-s2.0-85175403071
[ Google Scholar ]
URI
https://vinar.vin.bg.ac.rs/handle/123456789/11932
Колекције
  • Radovi istraživača
  • HIGHTONE-P
Институција/група
Vinča
TY  - CONF
AU  - Smiljanić, Ivan
AU  - Božović-Jelisavčić, Ivanka
AU  - Kačarević, Goran
AU  - Vukašinović, Nataša
AU  - Vidaković, Ivana
AU  - Reković, Vladimir
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11932
AB  - The very forward region is one of the most challenging regions to instrument at a future e+e−  collider. Machine-detector interface at CEPC will include a calorimeter dedicated for precision measurement of the integrated luminosity at a permill level or better. We discuss a feasibility of such precision from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background. Additionally, a method of the beam energy spread determination, initially proposed for FCC, is discussed for the CEPC beams, as well as the impact of beam energy spread uncertainty on integrated luminosity measurement and the precision of electroweak observables determination at the Z0  pole.
C3  - Proceedings of Science
T1  - Systematic uncertainties in integrated luminosity measurement at CEPC
VL  - 427
SP  - 193246
DO  - 10.22323/1.427.0086
ER  - 
@conference{
author = "Smiljanić, Ivan and Božović-Jelisavčić, Ivanka and Kačarević, Goran and Vukašinović, Nataša and Vidaković, Ivana and Reković, Vladimir",
year = "2023",
abstract = "The very forward region is one of the most challenging regions to instrument at a future e+e−  collider. Machine-detector interface at CEPC will include a calorimeter dedicated for precision measurement of the integrated luminosity at a permill level or better. We discuss a feasibility of such precision from the point of view of systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background. Additionally, a method of the beam energy spread determination, initially proposed for FCC, is discussed for the CEPC beams, as well as the impact of beam energy spread uncertainty on integrated luminosity measurement and the precision of electroweak observables determination at the Z0  pole.",
journal = "Proceedings of Science",
title = "Systematic uncertainties in integrated luminosity measurement at CEPC",
volume = "427",
pages = "193246",
doi = "10.22323/1.427.0086"
}
Smiljanić, I., Božović-Jelisavčić, I., Kačarević, G., Vukašinović, N., Vidaković, I.,& Reković, V.. (2023). Systematic uncertainties in integrated luminosity measurement at CEPC. in Proceedings of Science, 427, 193246.
https://doi.org/10.22323/1.427.0086
Smiljanić I, Božović-Jelisavčić I, Kačarević G, Vukašinović N, Vidaković I, Reković V. Systematic uncertainties in integrated luminosity measurement at CEPC. in Proceedings of Science. 2023;427:193246.
doi:10.22323/1.427.0086 .
Smiljanić, Ivan, Božović-Jelisavčić, Ivanka, Kačarević, Goran, Vukašinović, Nataša, Vidaković, Ivana, Reković, Vladimir, "Systematic uncertainties in integrated luminosity measurement at CEPC" in Proceedings of Science, 427 (2023):193246,
https://doi.org/10.22323/1.427.0086 . .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB