ВинаР - Репозиторијум Института за нуклеарне науке Винча
    • English
    • Српски
    • Српски (Serbia)
  • Српски (ћирилица) 
    • Енглески
    • Српски (ћирилица)
    • Српски (латиница)
  • Пријава
Преглед записа 
  •   ВинаР
  • Vinča
  • Radovi istraživača
  • Преглед записа
  •   ВинаР
  • Vinča
  • Radovi istraživača
  • Преглед записа
JavaScript is disabled for your browser. Some features of this site may not work without it.

Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation

Thumbnail
2020
Преузимање 🢃
Conference object [PDF] (1.192Mb)
Аутори
Kržanović, Nikola
Živanović, Miloš
Morosh, Viacheslav
Neumaier, Stefan
Röttger, Annette
Iurlaro, Giorgia
Bell, Stevan
Sangiorgi, Marco
Ciraj-Bjelac, Olivera
Pantelić, Gordana
Đaletić, Miloš
Sperandio, Luciano
Ioannidis, Sotiris
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
Non-governmental networks for environmental monitoring employ a wide range of radiation protection instruments from different manufacturers, which provide the public with often unreliable dosimetric data. These Measuring Instruments in Non-governmental Networks (MINN) are mostly based on Geiger-Muller tube gas detectors, which represent low-cost easily operated instruments. An extensive testing of these devices was performed in order to validate the data acquired with MINN within the 16ENV04 Preparedness EMPIR project. In total, 16 different dosemter types were selected, with a sample size of four dosemeters per dosemeter type. Performance testing included the energy dependence and the linearity tests of the dosemeter response. Additionally, during the Researcher Mobility Grant associated with the 16ENV04 project, two Geiger-Muller based dosemeter types, with a sample size of two dosemeters per type were included in the testing. These instruments were subjected to the angular dependenc...e testing in both horizontal and vertical planes, besides the energy dependence and linearity tests in the reference Cs-137 field at Physikalisch-Technische Bundesanstalt (PTB). For all the dosemeter types, inherent background, response to secondary cosmic radiation and the response to small changes of dose rate were determined at the metrological facilities of PTB. The sensitivity of the measuring instruments used in non-governmental networks to small variations of the ambient dose equivalent rate was examined by exposing the dosemeters to low dose rate Cs-137, Co-60 and Ra-226 radiation sources, in order to estimate the effect of environmental radioactive contamination with artificially produced radionuclides. For the comparison purposes, besides the measuring instruments used in non-governmental networks, a previously characterized CdZnTe-based spectrodosemeter was irradiated with the aforementioned radiation fields. The measured values were compared with a reference Reuter-Stokes ionisation chamber used for low-dose rate level measurements.

Извор:
RAP 2020 : International conference on radiation applications; Book of abstracts, 2020, 11-11
Издавач:
  • Niš : Sievert Association
Напомена:
  • RAP 2020 : International conference on radiation applications; Book of abstracts; Virtual conference, 2020

ISBN: 978-86-81652-02-2

[ Google Scholar ]
Handle
https://hdl.handle.net/21.15107/rcub_vinar_11905
URI
https://vinar.vin.bg.ac.rs/handle/123456789/11905
Колекције
  • Radovi istraživača
Институција/група
Vinča
TY  - CONF
AU  - Kržanović, Nikola
AU  - Živanović, Miloš
AU  - Morosh, Viacheslav
AU  - Neumaier, Stefan
AU  - Röttger, Annette
AU  - Iurlaro, Giorgia
AU  - Bell, Stevan
AU  - Sangiorgi, Marco
AU  - Ciraj-Bjelac, Olivera
AU  - Pantelić, Gordana
AU  - Đaletić, Miloš
AU  - Sperandio, Luciano
AU  - Ioannidis, Sotiris
PY  - 2020
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/11905
AB  - Non-governmental networks for environmental monitoring employ a wide range of radiation protection instruments from different manufacturers, which provide the public with often unreliable dosimetric data. These Measuring Instruments in Non-governmental Networks (MINN) are mostly based on Geiger-Muller tube gas detectors, which represent low-cost easily operated instruments. An extensive testing of these devices was performed in order to validate the data acquired with MINN within the 16ENV04 Preparedness EMPIR project. In total, 16 different dosemter types were selected, with a sample size of four dosemeters per dosemeter type. Performance testing included the energy dependence and the linearity tests of the dosemeter response. Additionally, during the Researcher Mobility Grant associated with the 16ENV04 project, two Geiger-Muller based dosemeter types, with a sample size of two dosemeters per type were included in the testing. These instruments were subjected to the angular dependence testing in both horizontal and vertical planes, besides the energy dependence and linearity tests in the reference Cs-137 field at Physikalisch-Technische Bundesanstalt (PTB). For all the dosemeter types, inherent background, response to secondary cosmic radiation and the response to small changes of dose rate were determined at the metrological facilities of PTB. The sensitivity of the measuring instruments used in non-governmental networks to small variations of the ambient dose equivalent rate was examined by exposing the dosemeters to low dose rate Cs-137, Co-60 and Ra-226 radiation sources, in order to estimate the effect of environmental radioactive contamination with artificially produced radionuclides. For the comparison purposes, besides the measuring instruments used in non-governmental networks, a previously characterized CdZnTe-based spectrodosemeter was irradiated with the aforementioned radiation fields. The measured values were compared with a reference Reuter-Stokes ionisation chamber used for low-dose rate level measurements.
PB  - Niš : Sievert Association
C3  - RAP 2020 : International conference on radiation applications; Book of abstracts
T1  - Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation
SP  - 11
EP  - 11
UR  - https://hdl.handle.net/21.15107/rcub_vinar_11905
ER  - 
@conference{
author = "Kržanović, Nikola and Živanović, Miloš and Morosh, Viacheslav and Neumaier, Stefan and Röttger, Annette and Iurlaro, Giorgia and Bell, Stevan and Sangiorgi, Marco and Ciraj-Bjelac, Olivera and Pantelić, Gordana and Đaletić, Miloš and Sperandio, Luciano and Ioannidis, Sotiris",
year = "2020",
abstract = "Non-governmental networks for environmental monitoring employ a wide range of radiation protection instruments from different manufacturers, which provide the public with often unreliable dosimetric data. These Measuring Instruments in Non-governmental Networks (MINN) are mostly based on Geiger-Muller tube gas detectors, which represent low-cost easily operated instruments. An extensive testing of these devices was performed in order to validate the data acquired with MINN within the 16ENV04 Preparedness EMPIR project. In total, 16 different dosemter types were selected, with a sample size of four dosemeters per dosemeter type. Performance testing included the energy dependence and the linearity tests of the dosemeter response. Additionally, during the Researcher Mobility Grant associated with the 16ENV04 project, two Geiger-Muller based dosemeter types, with a sample size of two dosemeters per type were included in the testing. These instruments were subjected to the angular dependence testing in both horizontal and vertical planes, besides the energy dependence and linearity tests in the reference Cs-137 field at Physikalisch-Technische Bundesanstalt (PTB). For all the dosemeter types, inherent background, response to secondary cosmic radiation and the response to small changes of dose rate were determined at the metrological facilities of PTB. The sensitivity of the measuring instruments used in non-governmental networks to small variations of the ambient dose equivalent rate was examined by exposing the dosemeters to low dose rate Cs-137, Co-60 and Ra-226 radiation sources, in order to estimate the effect of environmental radioactive contamination with artificially produced radionuclides. For the comparison purposes, besides the measuring instruments used in non-governmental networks, a previously characterized CdZnTe-based spectrodosemeter was irradiated with the aforementioned radiation fields. The measured values were compared with a reference Reuter-Stokes ionisation chamber used for low-dose rate level measurements.",
publisher = "Niš : Sievert Association",
journal = "RAP 2020 : International conference on radiation applications; Book of abstracts",
title = "Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation",
pages = "11-11",
url = "https://hdl.handle.net/21.15107/rcub_vinar_11905"
}
Kržanović, N., Živanović, M., Morosh, V., Neumaier, S., Röttger, A., Iurlaro, G., Bell, S., Sangiorgi, M., Ciraj-Bjelac, O., Pantelić, G., Đaletić, M., Sperandio, L.,& Ioannidis, S.. (2020). Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation. in RAP 2020 : International conference on radiation applications; Book of abstracts
Niš : Sievert Association., 11-11.
https://hdl.handle.net/21.15107/rcub_vinar_11905
Kržanović N, Živanović M, Morosh V, Neumaier S, Röttger A, Iurlaro G, Bell S, Sangiorgi M, Ciraj-Bjelac O, Pantelić G, Đaletić M, Sperandio L, Ioannidis S. Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation. in RAP 2020 : International conference on radiation applications; Book of abstracts. 2020;:11-11.
https://hdl.handle.net/21.15107/rcub_vinar_11905 .
Kržanović, Nikola, Živanović, Miloš, Morosh, Viacheslav, Neumaier, Stefan, Röttger, Annette, Iurlaro, Giorgia, Bell, Stevan, Sangiorgi, Marco, Ciraj-Bjelac, Olivera, Pantelić, Gordana, Đaletić, Miloš, Sperandio, Luciano, Ioannidis, Sotiris, "Testing of the measuring instruments in non-governmental networks for the purpose of environmental monitoring of ionising radiation" in RAP 2020 : International conference on radiation applications; Book of abstracts (2020):11-11,
https://hdl.handle.net/21.15107/rcub_vinar_11905 .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму ВинаР | Пошаљите запажања

re3dataOpenAIRERCUB