Interpretative optimization of the isocratic ion chromatographic separation of anions
Апстракт
Interpretive retention modeling was utilized to optimize the isocratic ion chromatographic (IC) separation of the nine anions (formate, fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate and oxalate). The carbonate-bicarbonate eluent was used and separation was done on a Dionex AS14 ion-exchange column. The influence of combined effects of two mobile phase factors, the total eluent concentration (2-6 mM) and the carbonate/bicaronate ratio from 1:9 to 9:1 (which correspond to pH range 9.35-11.27), on the IC separation was studied. The multiple species analyte/eluent model that takes into account ion-exchange equilibria of the eluent and sample anions was used. In order to estimate the parameters in the model, a non-linear fitting of the retention data, obtained at two-factor three-level experimental design, was applied. To find the optimal conditions in the experimental design, the normalized resolution product as a chromatographic objective function was employed. This cr...iterion includes both the individual peak resolution and the total analysis time. A good agreement between experimental and simulated chromatograms was obtained.
Кључне речи:
anions / ion chromatography / isocratic / multiple species analyte//eluent / resolution productИзвор:
Journal of the Serbian Chemical Society, 2016, 81, 6, 661-672Финансирање / пројекти:
- Нове технологије за мониторинг и заштиту животног окружења од штетних хемијских супстанци и радијационог оптерећења (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)
DOI: 10.2298/JSC150927022T
ISSN: 0352-5139
WoS: 000380246500005
Scopus: 2-s2.0-84979058874
Колекције
Институција/група
VinčaTY - JOUR AU - Todorović, Žaklina AU - Rajaković, Ljubinka V. AU - Onjia, Antonije E. PY - 2016 UR - https://vinar.vin.bg.ac.rs/handle/123456789/1188 AB - Interpretive retention modeling was utilized to optimize the isocratic ion chromatographic (IC) separation of the nine anions (formate, fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate and oxalate). The carbonate-bicarbonate eluent was used and separation was done on a Dionex AS14 ion-exchange column. The influence of combined effects of two mobile phase factors, the total eluent concentration (2-6 mM) and the carbonate/bicaronate ratio from 1:9 to 9:1 (which correspond to pH range 9.35-11.27), on the IC separation was studied. The multiple species analyte/eluent model that takes into account ion-exchange equilibria of the eluent and sample anions was used. In order to estimate the parameters in the model, a non-linear fitting of the retention data, obtained at two-factor three-level experimental design, was applied. To find the optimal conditions in the experimental design, the normalized resolution product as a chromatographic objective function was employed. This criterion includes both the individual peak resolution and the total analysis time. A good agreement between experimental and simulated chromatograms was obtained. T2 - Journal of the Serbian Chemical Society T1 - Interpretative optimization of the isocratic ion chromatographic separation of anions VL - 81 IS - 6 SP - 661 EP - 672 DO - 10.2298/JSC150927022T ER -
@article{ author = "Todorović, Žaklina and Rajaković, Ljubinka V. and Onjia, Antonije E.", year = "2016", abstract = "Interpretive retention modeling was utilized to optimize the isocratic ion chromatographic (IC) separation of the nine anions (formate, fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate and oxalate). The carbonate-bicarbonate eluent was used and separation was done on a Dionex AS14 ion-exchange column. The influence of combined effects of two mobile phase factors, the total eluent concentration (2-6 mM) and the carbonate/bicaronate ratio from 1:9 to 9:1 (which correspond to pH range 9.35-11.27), on the IC separation was studied. The multiple species analyte/eluent model that takes into account ion-exchange equilibria of the eluent and sample anions was used. In order to estimate the parameters in the model, a non-linear fitting of the retention data, obtained at two-factor three-level experimental design, was applied. To find the optimal conditions in the experimental design, the normalized resolution product as a chromatographic objective function was employed. This criterion includes both the individual peak resolution and the total analysis time. A good agreement between experimental and simulated chromatograms was obtained.", journal = "Journal of the Serbian Chemical Society", title = "Interpretative optimization of the isocratic ion chromatographic separation of anions", volume = "81", number = "6", pages = "661-672", doi = "10.2298/JSC150927022T" }
Todorović, Ž., Rajaković, L. V.,& Onjia, A. E.. (2016). Interpretative optimization of the isocratic ion chromatographic separation of anions. in Journal of the Serbian Chemical Society, 81(6), 661-672. https://doi.org/10.2298/JSC150927022T
Todorović Ž, Rajaković LV, Onjia AE. Interpretative optimization of the isocratic ion chromatographic separation of anions. in Journal of the Serbian Chemical Society. 2016;81(6):661-672. doi:10.2298/JSC150927022T .
Todorović, Žaklina, Rajaković, Ljubinka V., Onjia, Antonije E., "Interpretative optimization of the isocratic ion chromatographic separation of anions" in Journal of the Serbian Chemical Society, 81, no. 6 (2016):661-672, https://doi.org/10.2298/JSC150927022T . .