JavaScript is disabled for your browser. Some features of this site may not work without it.

The environmentally friendly approaches based on the heterojunction interface of the LaFeO3/Fe2O3@g-C3N4 composite for the disposable and laboratory sensing of triclosan

Authorized Users Only
2023
Authors
Knežević, Sara
Ostojić, Jelena
Ognjanović, Miloš
Savić, Slađana
Kovačević, Aleksandra
Manojlović, Dragan
Stanković, Vesna
Stanković, Dalibor M.
Article (Published version)
Metadata
Show full item record
Abstract
Triclosan (TCS) is a polychlorinated phenoxy phenol (PCPPs) used as a disinfectant and a broad-spectrum antibacterial and antifungal agent in personal hygiene products. TCS easily forms diphenyl ethers and dioxins, which are persistent organic pollutants. This work used a double approach for the TSC sensing: a) screen-printed (SPE) electrochemical platform for on-site application, modified with lanthanum iron oxide and graphitic carbon nitride composite (LaFeO3/Fe2O3@g-C3N4/SPE); and b) carbon paste electrode (CPE), modified with the same material and used in laboratory conditions. Linear range from 0.1 μM to 10 μM, the limit of detection (LOD) of 29 nM and the limit of quantification (LOQ) of 91 nM were obtained for CP electrode in BRBS pH 8. SPE showed the best analytical parameters in BRBS at pH 3, with a linear range from 0.3 μM to 7 μM, LOD of 0.09 μM and LOQ of 0.28 μM. Furthermore, the influence of potential interferents was investigated and proven to be negligible. Determinatio...n of TSC was performed to estimate the environmental impact of this compound as well as the practical usefulness of the proposed sensor in the real sample analysis, confirmed with a HPLC analysis. © 2022 Elsevier B.V.

Keywords:
Electrochemical sensor / Graphitic carbon nitride / Green analytical chemistry / LaFeO3/Fe2O3 / Triclosan
Source:
Science of the Total Environment, 2023, 857
Funding / projects:
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200168 (University of Belgrade, Faculty of Chemistry) (RS-200168)
  • EUREKA [Project E!13303]

DOI: 10.1016/j.scitotenv.2022.159250

ISSN: 0048-9697

PubMed: 36208761

Scopus: 2-s2.0-85140139751
[ Google Scholar ]
URI
https://vinar.vin.bg.ac.rs/handle/123456789/10468
Collections
  • Radovi istraživača
Institution/Community
Vinča
TY  - JOUR
AU  - Knežević, Sara
AU  - Ostojić, Jelena
AU  - Ognjanović, Miloš
AU  - Savić, Slađana
AU  - Kovačević, Aleksandra
AU  - Manojlović, Dragan
AU  - Stanković, Vesna
AU  - Stanković, Dalibor M.
PY  - 2023
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/10468
AB  - Triclosan (TCS) is a polychlorinated phenoxy phenol (PCPPs) used as a disinfectant and a broad-spectrum antibacterial and antifungal agent in personal hygiene products. TCS easily forms diphenyl ethers and dioxins, which are persistent organic pollutants. This work used a double approach for the TSC sensing: a) screen-printed (SPE) electrochemical platform for on-site application, modified with lanthanum iron oxide and graphitic carbon nitride composite (LaFeO3/Fe2O3@g-C3N4/SPE); and b) carbon paste electrode (CPE), modified with the same material and used in laboratory conditions. Linear range from 0.1 μM to 10 μM, the limit of detection (LOD) of 29 nM and the limit of quantification (LOQ) of 91 nM were obtained for CP electrode in BRBS pH 8. SPE showed the best analytical parameters in BRBS at pH 3, with a linear range from 0.3 μM to 7 μM, LOD of 0.09 μM and LOQ of 0.28 μM. Furthermore, the influence of potential interferents was investigated and proven to be negligible. Determination of TSC was performed to estimate the environmental impact of this compound as well as the practical usefulness of the proposed sensor in the real sample analysis, confirmed with a HPLC analysis. © 2022 Elsevier B.V.
T2  - Science of the Total Environment
T1  - The environmentally friendly approaches based on the heterojunction interface of the LaFeO3/Fe2O3@g-C3N4 composite for the disposable and laboratory sensing of triclosan
VL  - 857
DO  - 10.1016/j.scitotenv.2022.159250
ER  - 
@article{
author = "Knežević, Sara and Ostojić, Jelena and Ognjanović, Miloš and Savić, Slađana and Kovačević, Aleksandra and Manojlović, Dragan and Stanković, Vesna and Stanković, Dalibor M.",
year = "2023",
abstract = "Triclosan (TCS) is a polychlorinated phenoxy phenol (PCPPs) used as a disinfectant and a broad-spectrum antibacterial and antifungal agent in personal hygiene products. TCS easily forms diphenyl ethers and dioxins, which are persistent organic pollutants. This work used a double approach for the TSC sensing: a) screen-printed (SPE) electrochemical platform for on-site application, modified with lanthanum iron oxide and graphitic carbon nitride composite (LaFeO3/Fe2O3@g-C3N4/SPE); and b) carbon paste electrode (CPE), modified with the same material and used in laboratory conditions. Linear range from 0.1 μM to 10 μM, the limit of detection (LOD) of 29 nM and the limit of quantification (LOQ) of 91 nM were obtained for CP electrode in BRBS pH 8. SPE showed the best analytical parameters in BRBS at pH 3, with a linear range from 0.3 μM to 7 μM, LOD of 0.09 μM and LOQ of 0.28 μM. Furthermore, the influence of potential interferents was investigated and proven to be negligible. Determination of TSC was performed to estimate the environmental impact of this compound as well as the practical usefulness of the proposed sensor in the real sample analysis, confirmed with a HPLC analysis. © 2022 Elsevier B.V.",
journal = "Science of the Total Environment",
title = "The environmentally friendly approaches based on the heterojunction interface of the LaFeO3/Fe2O3@g-C3N4 composite for the disposable and laboratory sensing of triclosan",
volume = "857",
doi = "10.1016/j.scitotenv.2022.159250"
}
Knežević, S., Ostojić, J., Ognjanović, M., Savić, S., Kovačević, A., Manojlović, D., Stanković, V.,& Stanković, D. M.. (2023). The environmentally friendly approaches based on the heterojunction interface of the LaFeO3/Fe2O3@g-C3N4 composite for the disposable and laboratory sensing of triclosan. in Science of the Total Environment, 857.
https://doi.org/10.1016/j.scitotenv.2022.159250
Knežević S, Ostojić J, Ognjanović M, Savić S, Kovačević A, Manojlović D, Stanković V, Stanković DM. The environmentally friendly approaches based on the heterojunction interface of the LaFeO3/Fe2O3@g-C3N4 composite for the disposable and laboratory sensing of triclosan. in Science of the Total Environment. 2023;857.
doi:10.1016/j.scitotenv.2022.159250 .
Knežević, Sara, Ostojić, Jelena, Ognjanović, Miloš, Savić, Slađana, Kovačević, Aleksandra, Manojlović, Dragan, Stanković, Vesna, Stanković, Dalibor M., "The environmentally friendly approaches based on the heterojunction interface of the LaFeO3/Fe2O3@g-C3N4 composite for the disposable and laboratory sensing of triclosan" in Science of the Total Environment, 857 (2023),
https://doi.org/10.1016/j.scitotenv.2022.159250 . .

DSpace software copyright © 2002-2015  DuraSpace
About the VinaR Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About the VinaR Repository | Send Feedback

OpenAIRERCUB