Приказ основних података о документу

dc.creatorBožilov, Aca
dc.creatorTasić, Viša
dc.creatorŽivković, Nenad
dc.creatorLazović, Ivan
dc.creatorBlagojević, Milan
dc.creatorMišić, Nikola
dc.creatorTopalović, Dušan
dc.date.accessioned2022-08-31T10:34:59Z
dc.date.available2022-08-31T10:34:59Z
dc.date.issued2022
dc.identifier.issn1573-2959
dc.identifier.urihttps://vinar.vin.bg.ac.rs/handle/123456789/10372
dc.description.abstractOver the last 10 years, as a possible alternative to the conventional approach to air quality monitoring, real-time monitoring systems that use low-cost sensors and sensor platforms have been frequently applied. Generally, the long-term characteristics of low-cost PM sensors and monitoring have not been thoroughly documented except for a few widely used sensors and monitors. This article addresses the laboratory and field validation of three low-cost PM monitors of the same type that use the NOVA SDS011 PM sensor module over a 1-year period. In outdoor environments, we co-located low-cost PM monitors with GRIMM EDM180 monitors at the National Air Quality Monitoring stations. In indoor environments, we co-located them with a Turnkey Osiris PM monitor. Several performance aspects of the PM monitors were examined: operational data coverage, linearity of response, accuracy, precision, and inter-sensor variability. The obtained results show that inter-monitor R values were typically higher than 0.95 regardless of the environment. The tested monitors demonstrate high linearity in comparison with PM10 and PM2.5 concentrations measured in outdoor air with reference-equivalent instrumentation with R2 values ranging from 0.52 up to 0.83. In addition, very good agreement (R2 values ranging from 0.93 up to 0.97) with the gravimetric PM10 and PM2.5 method is obtained in the indoor environment (30 < RH < 70%). High RH (over 70%) negatively affected the PM monitors’ response, especially in the case of PM10 concentrations (high overestimation).en
dc.languageen
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200052/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200148/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200017/RS//
dc.rightsrestrictedAccess
dc.sourceEnvironmental Monitoring and Assessment
dc.subjectAir pollutionen
dc.subjectLow-cost PM monitoren
dc.subjectMonitoringen
dc.subjectNOVA SDS011 PM sensoren
dc.subjectParticulate matteren
dc.titlePerformance assessment of NOVA SDS011 low-cost PM sensor in various microenvironmentsen
dc.typearticleen
dc.rights.licenseARR
dc.citation.volume194
dc.citation.issue9
dc.citation.spage595
dc.identifier.wos00082811660000
dc.identifier.doi10.1007/s10661-022-10290-7
dc.identifier.pmid35857115
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85134434603


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама