Development and Modeling of Energy-Efficient, Adaptable, Multiprocessor and Multisensor Low-Power Electronic Systems

Link to this page

info:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/32043/RS//

Development and Modeling of Energy-Efficient, Adaptable, Multiprocessor and Multisensor Low-Power Electronic Systems (en)
Развој и моделовање енергетски ефикасних, адаптабилних, вишепроцесорских и вишесензорских електронских система мале снаге (sr)
Razvoj i modelovanje energetski efikasnih, adaptabilnih, višeprocesorskih i višesenzorskih elektronskih sistema male snage (sr_RS)
Authors

Publications

Monitoring of the seismic activity using high sensitivity MEMS accelerometer

Klisić, Đorđe; Radovanović, Ilija; Bežanić, Nikola; Stamenić, Ljubisav; Popović, Ivan

(Beograd : Društvo za ETRAN, 2014)

TY  - CONF
AU  - Klisić, Đorđe
AU  - Radovanović, Ilija
AU  - Bežanić, Nikola
AU  - Stamenić, Ljubisav
AU  - Popović, Ivan
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/12463
AB  - MEMS sensors are widely used type of sensors that can be found in many modern gadgets. Affordable price and small dimensions in combination with high sensitivity and precision made them interesting candidates for the wide range applications in various fields. In case of seismology, application of MEMS accelerometer is still in the shadow of the classical accelerometers with the inertial element, although the characteristics of the today MEMS accelerometers can easily match the classical ones. In this paper group of authors decided to test characteristics of the high sensitivity accelerometer and to determine if it is suitable for the applications in seismology. The requirements that sensor had to meet are high sensitivity and noise level below the threshold of human detectable vibrations which is around four degrees of the Mercalli scale or the ground acceleration between 0.015g and 0.04g.
PB  - Beograd : Društvo za ETRAN
C3  - ETRAN : 58. konferencija ETRAN-a : Zbornik apstrakata i program
T1  - Monitoring of the seismic activity using high sensitivity MEMS accelerometer
SP  - MLI2.2.1
EP  - MLI2.2.5
UR  - https://hdl.handle.net/21.15107/rcub_vinar_12463
ER  - 
@conference{
author = "Klisić, Đorđe and Radovanović, Ilija and Bežanić, Nikola and Stamenić, Ljubisav and Popović, Ivan",
year = "2014",
abstract = "MEMS sensors are widely used type of sensors that can be found in many modern gadgets. Affordable price and small dimensions in combination with high sensitivity and precision made them interesting candidates for the wide range applications in various fields. In case of seismology, application of MEMS accelerometer is still in the shadow of the classical accelerometers with the inertial element, although the characteristics of the today MEMS accelerometers can easily match the classical ones. In this paper group of authors decided to test characteristics of the high sensitivity accelerometer and to determine if it is suitable for the applications in seismology. The requirements that sensor had to meet are high sensitivity and noise level below the threshold of human detectable vibrations which is around four degrees of the Mercalli scale or the ground acceleration between 0.015g and 0.04g.",
publisher = "Beograd : Društvo za ETRAN",
journal = "ETRAN : 58. konferencija ETRAN-a : Zbornik apstrakata i program",
title = "Monitoring of the seismic activity using high sensitivity MEMS accelerometer",
pages = "MLI2.2.1-MLI2.2.5",
url = "https://hdl.handle.net/21.15107/rcub_vinar_12463"
}
Klisić, Đ., Radovanović, I., Bežanić, N., Stamenić, L.,& Popović, I.. (2014). Monitoring of the seismic activity using high sensitivity MEMS accelerometer. in ETRAN : 58. konferencija ETRAN-a : Zbornik apstrakata i program
Beograd : Društvo za ETRAN., MLI2.2.1-MLI2.2.5.
https://hdl.handle.net/21.15107/rcub_vinar_12463
Klisić Đ, Radovanović I, Bežanić N, Stamenić L, Popović I. Monitoring of the seismic activity using high sensitivity MEMS accelerometer. in ETRAN : 58. konferencija ETRAN-a : Zbornik apstrakata i program. 2014;:MLI2.2.1-MLI2.2.5.
https://hdl.handle.net/21.15107/rcub_vinar_12463 .
Klisić, Đorđe, Radovanović, Ilija, Bežanić, Nikola, Stamenić, Ljubisav, Popović, Ivan, "Monitoring of the seismic activity using high sensitivity MEMS accelerometer" in ETRAN : 58. konferencija ETRAN-a : Zbornik apstrakata i program (2014):MLI2.2.1-MLI2.2.5,
https://hdl.handle.net/21.15107/rcub_vinar_12463 .

Voltage Controlled Power Characteristics of a Custom Made Laser Diode Assembly

Klisić, Đorđe; Radovanović, Ilija; Bežanić, Nikola; Stamenić, Ljubisav; Popović, Ivan

(IEEE : Institute of Electrical and Electronics Engineers, 2014)

TY  - CONF
AU  - Klisić, Đorđe
AU  - Radovanović, Ilija
AU  - Bežanić, Nikola
AU  - Stamenić, Ljubisav
AU  - Popović, Ivan
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/7155
AB  - Construction and characterization of a simple but flexible, low cost diode laser system for the excitation of carbon quantum dots as a treatment method for ocular cancers is reported. System was designed to deliver maximal amount of laser diode radiant flux to the eye of the test mice using optical cable. Detailed electronic circuit layouts of the laser diode voltage controller, supplying maximum 3 V of voltage with 20 mV resolutions, and functional description of all other components (optical cable delivery system and supporting console) are given. The system features visual signalization when the laser diode module is powered. Since the laser diode radiant flux is directly dependent on the input voltage, measurement was performed in order to obtain approximation function of this dependency. Purpose of this function is to eliminate radiant flux measurement before each experiment which requires controlled conditions.
PB  - IEEE : Institute of Electrical and Electronics Engineers
C3  - 22nd Telecommunications Forum Telfor (TELFOR) : Proceedings
T1  - Voltage Controlled Power Characteristics of a Custom Made Laser Diode Assembly
SP  - 633
EP  - 636
DO  - 10.1109/TELFOR.2014.7034488
UR  - https://hdl.handle.net/21.15107/rcub_vinar_7155
ER  - 
@conference{
author = "Klisić, Đorđe and Radovanović, Ilija and Bežanić, Nikola and Stamenić, Ljubisav and Popović, Ivan",
year = "2014",
abstract = "Construction and characterization of a simple but flexible, low cost diode laser system for the excitation of carbon quantum dots as a treatment method for ocular cancers is reported. System was designed to deliver maximal amount of laser diode radiant flux to the eye of the test mice using optical cable. Detailed electronic circuit layouts of the laser diode voltage controller, supplying maximum 3 V of voltage with 20 mV resolutions, and functional description of all other components (optical cable delivery system and supporting console) are given. The system features visual signalization when the laser diode module is powered. Since the laser diode radiant flux is directly dependent on the input voltage, measurement was performed in order to obtain approximation function of this dependency. Purpose of this function is to eliminate radiant flux measurement before each experiment which requires controlled conditions.",
publisher = "IEEE : Institute of Electrical and Electronics Engineers",
journal = "22nd Telecommunications Forum Telfor (TELFOR) : Proceedings",
title = "Voltage Controlled Power Characteristics of a Custom Made Laser Diode Assembly",
pages = "633-636",
doi = "10.1109/TELFOR.2014.7034488",
url = "https://hdl.handle.net/21.15107/rcub_vinar_7155"
}
Klisić, Đ., Radovanović, I., Bežanić, N., Stamenić, L.,& Popović, I.. (2014). Voltage Controlled Power Characteristics of a Custom Made Laser Diode Assembly. in 22nd Telecommunications Forum Telfor (TELFOR) : Proceedings
IEEE : Institute of Electrical and Electronics Engineers., 633-636.
https://doi.org/10.1109/TELFOR.2014.7034488
https://hdl.handle.net/21.15107/rcub_vinar_7155
Klisić Đ, Radovanović I, Bežanić N, Stamenić L, Popović I. Voltage Controlled Power Characteristics of a Custom Made Laser Diode Assembly. in 22nd Telecommunications Forum Telfor (TELFOR) : Proceedings. 2014;:633-636.
doi:10.1109/TELFOR.2014.7034488
https://hdl.handle.net/21.15107/rcub_vinar_7155 .
Klisić, Đorđe, Radovanović, Ilija, Bežanić, Nikola, Stamenić, Ljubisav, Popović, Ivan, "Voltage Controlled Power Characteristics of a Custom Made Laser Diode Assembly" in 22nd Telecommunications Forum Telfor (TELFOR) : Proceedings (2014):633-636,
https://doi.org/10.1109/TELFOR.2014.7034488 .,
https://hdl.handle.net/21.15107/rcub_vinar_7155 .

Smart Ionization Chamber for Gamma-Ray Monitoring

Drndarevic, Vujo R.; Jevtic, Nenad J.; Rajovic, Vladimir M.; Stanković, Srboljub J.

(2014)

TY  - JOUR
AU  - Drndarevic, Vujo R.
AU  - Jevtic, Nenad J.
AU  - Rajovic, Vladimir M.
AU  - Stanković, Srboljub J.
PY  - 2014
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/165
AB  - A design and implementation of a smart ionization chamber suitable for connection into gamma radiation monitoring networks is presented in this paper. The smart ionization Chamber consists of air-equivalent one liter ionization chamber with associated electronics and a built-in memory for storage of electronic data specifications. Generally, operating and measurement characteristics of the used ionization chamber are written into the memory chip attached to the chamber. A microcontroller-based data acquisition system with a mixed-mode interface has been implemented for the purpose of reading electronic data specifications from the memory chip, and for configuration and interfacing of the ionization chamber to the monitoring network using plug-and-play concept. The details of smart ionization chamber implementation and test results are included in the paper.
T2  - Nuclear technology and radiation protection
T1  - Smart Ionization Chamber for Gamma-Ray Monitoring
VL  - 29
IS  - 3
SP  - 190
EP  - 198
DO  - 10.2298/NTRP1403190D
ER  - 
@article{
author = "Drndarevic, Vujo R. and Jevtic, Nenad J. and Rajovic, Vladimir M. and Stanković, Srboljub J.",
year = "2014",
abstract = "A design and implementation of a smart ionization chamber suitable for connection into gamma radiation monitoring networks is presented in this paper. The smart ionization Chamber consists of air-equivalent one liter ionization chamber with associated electronics and a built-in memory for storage of electronic data specifications. Generally, operating and measurement characteristics of the used ionization chamber are written into the memory chip attached to the chamber. A microcontroller-based data acquisition system with a mixed-mode interface has been implemented for the purpose of reading electronic data specifications from the memory chip, and for configuration and interfacing of the ionization chamber to the monitoring network using plug-and-play concept. The details of smart ionization chamber implementation and test results are included in the paper.",
journal = "Nuclear technology and radiation protection",
title = "Smart Ionization Chamber for Gamma-Ray Monitoring",
volume = "29",
number = "3",
pages = "190-198",
doi = "10.2298/NTRP1403190D"
}
Drndarevic, V. R., Jevtic, N. J., Rajovic, V. M.,& Stanković, S. J.. (2014). Smart Ionization Chamber for Gamma-Ray Monitoring. in Nuclear technology and radiation protection, 29(3), 190-198.
https://doi.org/10.2298/NTRP1403190D
Drndarevic VR, Jevtic NJ, Rajovic VM, Stanković SJ. Smart Ionization Chamber for Gamma-Ray Monitoring. in Nuclear technology and radiation protection. 2014;29(3):190-198.
doi:10.2298/NTRP1403190D .
Drndarevic, Vujo R., Jevtic, Nenad J., Rajovic, Vladimir M., Stanković, Srboljub J., "Smart Ionization Chamber for Gamma-Ray Monitoring" in Nuclear technology and radiation protection, 29, no. 3 (2014):190-198,
https://doi.org/10.2298/NTRP1403190D . .
2
2
2