Ministry for Science and Technological Development of Serbia [451 - 01 - 00049]

Link to this page

Ministry for Science and Technological Development of Serbia [451 - 01 - 00049]

Authors

Publications

Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation

Cirkovic, Sasa; Ristić-Đurović, Jasna L.; Ihic, Andjelija Z.; Vujović, Velibor V.; Negkovic, Nebojsa A.

(2008)

TY  - JOUR
AU  - Cirkovic, Sasa
AU  - Ristić-Đurović, Jasna L.
AU  - Ihic, Andjelija Z.
AU  - Vujović, Velibor V.
AU  - Negkovic, Nebojsa A.
PY  - 2008
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/3622
AB  - Accurate magnetic fields are needed for defining the operation of a multipurpose cyclotron as well as for designing other parts of the machine, as an input parameter. The quality of an isochronous magnetic field is evaluated by the closeness of the obtained ion gyration frequency to its required value. The commonly used method of isochronous field calculation for sector focused cyclotrons was Gordons procedure. The incorporation of the gyration frequency criterion in isochronous field calculation has grown with the increase of the computer speed. We suggest a highly accurate method for the isochronous magnetic field calculation based on the gyration frequency adjustment.
T2  - IEEE Transactions on Nuclear Science
T1  - Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation
VL  - 55
IS  - 6
SP  - 3531
EP  - 3538
DO  - 10.1109/TNS.2008.2005498
ER  - 
@article{
author = "Cirkovic, Sasa and Ristić-Đurović, Jasna L. and Ihic, Andjelija Z. and Vujović, Velibor V. and Negkovic, Nebojsa A.",
year = "2008",
abstract = "Accurate magnetic fields are needed for defining the operation of a multipurpose cyclotron as well as for designing other parts of the machine, as an input parameter. The quality of an isochronous magnetic field is evaluated by the closeness of the obtained ion gyration frequency to its required value. The commonly used method of isochronous field calculation for sector focused cyclotrons was Gordons procedure. The incorporation of the gyration frequency criterion in isochronous field calculation has grown with the increase of the computer speed. We suggest a highly accurate method for the isochronous magnetic field calculation based on the gyration frequency adjustment.",
journal = "IEEE Transactions on Nuclear Science",
title = "Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation",
volume = "55",
number = "6",
pages = "3531-3538",
doi = "10.1109/TNS.2008.2005498"
}
Cirkovic, S., Ristić-Đurović, J. L., Ihic, A. Z., Vujović, V. V.,& Negkovic, N. A.. (2008). Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation. in IEEE Transactions on Nuclear Science, 55(6), 3531-3538.
https://doi.org/10.1109/TNS.2008.2005498
Cirkovic S, Ristić-Đurović JL, Ihic AZ, Vujović VV, Negkovic NA. Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation. in IEEE Transactions on Nuclear Science. 2008;55(6):3531-3538.
doi:10.1109/TNS.2008.2005498 .
Cirkovic, Sasa, Ristić-Đurović, Jasna L., Ihic, Andjelija Z., Vujović, Velibor V., Negkovic, Nebojsa A., "Comparative Analysis of Methods for Isochronous Magnetic-Field Calculation" in IEEE Transactions on Nuclear Science, 55, no. 6 (2008):3531-3538,
https://doi.org/10.1109/TNS.2008.2005498 . .
10
10
10