Secretariat for Science and Technological Development, Autonomous Province of Vojvodina, Republic of Serbia [114-451-02011/2007-02], Ministry of Education, Youth and Sports of the Czech Republic [MSM0021627502], CEEPUS II program [CII-CZ-0212-04-1011]

Link to this page

Secretariat for Science and Technological Development, Autonomous Province of Vojvodina, Republic of Serbia [114-451-02011/2007-02], Ministry of Education, Youth and Sports of the Czech Republic [MSM0021627502], CEEPUS II program [CII-CZ-0212-04-1011]

Authors

Publications

Voltammetric Determination of the Herbicide Linuron Using a Tricresyl Phosphate-Based Carbon Paste Electrode

Đorđević, Jelena S.; Papp, Zsigmond; Guzsvany, Valeria; Svancara, Ivan; Trtić-Petrović, Tatjana M.; Purenović, Milovan M.; Vytras, Karel

(2012)

TY  - JOUR
AU  - Đorđević, Jelena S.
AU  - Papp, Zsigmond
AU  - Guzsvany, Valeria
AU  - Svancara, Ivan
AU  - Trtić-Petrović, Tatjana M.
AU  - Purenović, Milovan M.
AU  - Vytras, Karel
PY  - 2012
UR  - https://vinar.vin.bg.ac.rs/handle/123456789/4660
AB  - This paper summarises the results of voltammetric studies on the herbicide 3-(3,4-dichlorophenyl)-1-methoxy-1-methylurea (Linuron), using a carbon paste electrode containing tricresyl phosphate (TCP-CPE) as liquid binder. The principal experimental conditions, such as the pH effect, investigated in Britton-Robinson buffer solutions (pH 2.0-7.0), the peak characteristics for the analyte of interest, or instrumental parameters for the differential pulse voltammetric mode were optimized for the method. As found out, the best electroanalytical performance of the TCP-CPE was achieved at pH 2.0, whereby the oxidation peak of Linuron appeared at ca. + 1.3 V vs. SCE. The analytical procedure developed offers good linearity in the concentration range of 1.25-44.20 mu g mL(-1) (1.77 x 10(-4)-5.05 x 10(-6) mol L-1), showing-for the first time-the applicability of the TCP-CPE for anodic oxidations in direct voltammetry (without accumulation). The method was then verified by determining Linuron in a spiked river water sample and a commercial formulation and the results obtained agreed well with those obtained by the reference HPLC/UV determination.
T2  - Sensors
T1  - Voltammetric Determination of the Herbicide Linuron Using a Tricresyl Phosphate-Based Carbon Paste Electrode
VL  - 12
IS  - 1
SP  - 148
EP  - 161
DO  - 10.3390/s120100148
ER  - 
@article{
author = "Đorđević, Jelena S. and Papp, Zsigmond and Guzsvany, Valeria and Svancara, Ivan and Trtić-Petrović, Tatjana M. and Purenović, Milovan M. and Vytras, Karel",
year = "2012",
abstract = "This paper summarises the results of voltammetric studies on the herbicide 3-(3,4-dichlorophenyl)-1-methoxy-1-methylurea (Linuron), using a carbon paste electrode containing tricresyl phosphate (TCP-CPE) as liquid binder. The principal experimental conditions, such as the pH effect, investigated in Britton-Robinson buffer solutions (pH 2.0-7.0), the peak characteristics for the analyte of interest, or instrumental parameters for the differential pulse voltammetric mode were optimized for the method. As found out, the best electroanalytical performance of the TCP-CPE was achieved at pH 2.0, whereby the oxidation peak of Linuron appeared at ca. + 1.3 V vs. SCE. The analytical procedure developed offers good linearity in the concentration range of 1.25-44.20 mu g mL(-1) (1.77 x 10(-4)-5.05 x 10(-6) mol L-1), showing-for the first time-the applicability of the TCP-CPE for anodic oxidations in direct voltammetry (without accumulation). The method was then verified by determining Linuron in a spiked river water sample and a commercial formulation and the results obtained agreed well with those obtained by the reference HPLC/UV determination.",
journal = "Sensors",
title = "Voltammetric Determination of the Herbicide Linuron Using a Tricresyl Phosphate-Based Carbon Paste Electrode",
volume = "12",
number = "1",
pages = "148-161",
doi = "10.3390/s120100148"
}
Đorđević, J. S., Papp, Z., Guzsvany, V., Svancara, I., Trtić-Petrović, T. M., Purenović, M. M.,& Vytras, K.. (2012). Voltammetric Determination of the Herbicide Linuron Using a Tricresyl Phosphate-Based Carbon Paste Electrode. in Sensors, 12(1), 148-161.
https://doi.org/10.3390/s120100148
Đorđević JS, Papp Z, Guzsvany V, Svancara I, Trtić-Petrović TM, Purenović MM, Vytras K. Voltammetric Determination of the Herbicide Linuron Using a Tricresyl Phosphate-Based Carbon Paste Electrode. in Sensors. 2012;12(1):148-161.
doi:10.3390/s120100148 .
Đorđević, Jelena S., Papp, Zsigmond, Guzsvany, Valeria, Svancara, Ivan, Trtić-Petrović, Tatjana M., Purenović, Milovan M., Vytras, Karel, "Voltammetric Determination of the Herbicide Linuron Using a Tricresyl Phosphate-Based Carbon Paste Electrode" in Sensors, 12, no. 1 (2012):148-161,
https://doi.org/10.3390/s120100148 . .
25
24
24